MULTIPLE CHOICE QUESTION

30 sec • 2 pts

What conponent is used to Help return the Carry away water from the Cooling Tower .
The Float control Switch in the Tower Sump .
The Spray Nozzel
Water Elliminator
The AquaStat Control

2.

MULTIPLE CHOICE QUESTION

30 sec • 2 pts

If the Float control switch was to get stuck down . Will the Cooling Tower be able to maintain the proper water level inside the Sump
Yes
No
Maybe

3.

MULTIPLE CHOICE QUESTION

30 sec • 2 pts

During the Defrost Cycle of a Air to Air Heat Pump is the Electirc Heater energized to provide heat to the space to be condition ?
Yes
No

4.

MULTIPLE CHOICE QUESTION

30 sec • 2 pts

If the Forced Draft Coolin Tower Sump Strainer Basket get clogged up with Dirt and Scales build up . It can be clean by using ?
Removiing the access door and reach down and sliding the basket out and cleaned.
Removed the access door and lift up on the float control switch .
Cleaning th Y- Strainer at the Tower
All of the aboved

5.

MULTIPLE CHOICE QUESTION

30 sec • 2 pts

In a Air to Air Heat Pump , whenever the outdoor Ambient air temperature falls below 25.F is the Compressor energized ?
yes
no

6.

MULTIPLE CHOICE QUESTION

30 sec • 2 pts

If vortexting is Occuring inside the the sump . Do that mean that the float control is not working properly ?
Yes
No
maybe
None of the aboved

7.

MULTIPLE CHOICE QUESTION

30 sec • 2 pts

What conponent is used to help return the water back to the Cooling Tower
The Float control switch is the sump
The spray nozzels
The water Elliminators
The tower AquaStat