1.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

What would be the low side elevation of a sewer drain that has a 1/16" per ft of grade and is 48.08 feet long and starts at an elevation of 96 ft?

1. 97.00 ft
2. 95.75 ft
3. 95.50 ft
4. 95.00 ft
Math

Answer explanation

  • The sewer drain starts at 96 feet.

  • It drops a total of about 3 inches over 48.08 feet.

  • Converting 3 inches to feet gives us 0.25 feet.

  • Subtracting the drop from the starting elevation:

  • So, the low side elevation is approximately 95.75 feet.

2.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Where plumbing fixtures are installed on a floor with a finished floor elevation below the elevation of a manhole cover of the next upstream manhole in the public sewer, fixtures are protected by a backwater valve. Which of the following is required in a backflow valve?

1. water supply fixtures
2. pressure testing
3. cleanout
4. access
608.15

Answer explanation

3.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

In a hot water tank, temperature and pressure relief valves, or a combination of thereof, and energy cutoff devices shall have a temperature setting of not more than 210 degrees F and a working pressure of how many PSI?

1. 125
2. 200
3. 150
4. 210
504.5

4.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

According to the International Plumbing Code, every dry vent shall rise vertically opto a point not less than 6 inches above the flood level rim of the highest trap with > the exception of

1. interceptors located outdoors.
2. there is not an exception.
3. sports facilities shower.
4. sinks at a fast food restaurant.
905.4 Exception

5.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

What is the minimum air gap for sinks, laundry trays, gooseneck back faucets n and other fixtures with an effective opening of 1-1/4 inches?

1. 1 1/2 inches
2. 2 inches
3. 2 1/2 inches
4. 3 3/4 inches
802

6.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

According to the International Plumbing Code, a backwater valve is used to ก prevent drainage or waste from backing up into lower fixtures. Where shall the backwater valve be installed?

1. at a lower level fixture.
2. without any access.
3. in connection with a sanitary drainage.
4. in building drains subject to backflow.
202

7.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Using Table 906.1 of the International Plumbing Code, what is the smallest diameter of vent if a vent that is 65 feet long is servicing a 4 inch waste stack?

1. 1 inch
2. 3 inches
3. 2 1/2 inches
4. 2 inches
Table 906.1

Access all questions and much more by creating a free account