PT_CIDB_CW6

PT_CIDB_CW6

University

30 Qs

quiz-placeholder

Similar activities

MT_CIDB_EOCGEN

MT_CIDB_EOCGEN

University

30 Qs

MEASURE OF DISPERSION

MEASURE OF DISPERSION

University

33 Qs

Malaysian Legal System

Malaysian Legal System

University

25 Qs

EC8352-SIGNALS AND SYSTEMS-WEEKLY TEST 4

EC8352-SIGNALS AND SYSTEMS-WEEKLY TEST 4

University

30 Qs

engineering Graphics Test

engineering Graphics Test

University

30 Qs

Prueba Diagnóstica - Preparación y Evaluación de Proyectos

Prueba Diagnóstica - Preparación y Evaluación de Proyectos

University

30 Qs

CE W/S Retest - S2 Cyber

CE W/S Retest - S2 Cyber

University

25 Qs

EC8004 Wireless Network_ IAT2_Part-A

EC8004 Wireless Network_ IAT2_Part-A

University

30 Qs

PT_CIDB_CW6

PT_CIDB_CW6

Assessment

Quiz

Education

University

Easy

Created by

JAMADEEL IZWAN PMS

Used 9+ times

FREE Resource

30 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In accordance with BS EN ISO 3059 the minimum level of white light illumination for visible techniques is:

500 lux

200 lux

800 lux

1000 lux

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Background coloration will reduce sensitivity of a dye penetrant inspection. It is due to:

The natural colour of the component.

Incomplete removal of penetrant.

Lack of contrast between penetrant and developer.

Inadequate contrast between component and work piece.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Methods of assessing overall process capability include:

Cracked components.

Quench cracked aluminium blocks.

Slotted blocks.

Both a and b are correct.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which penetrant is best suited for overhead work?

Filtered particle.

Dual sensitivity.

Thixotropic.

Water washable

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Drainage time is:

The time allowed for drainage of applied fluids.

The time taken for test tanks to clear.

Time taken for penetrant to draw from defects.

The time for which a component is submerged.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A definition of hydrophilic remover is:

Water based and miscible in all proportions with water.

Oil based and miscible in all proportions with post-emulsifiable penetrant.

Water heating.

Using water for penetrant removal.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which document gives information on exposure limits for hazardous substances?

HSE.

COSHH.

EH40.

None of the above.

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?