Electrical Cable Knowledge Quiz

Electrical Cable Knowledge Quiz

Professional Development

20 Qs

quiz-placeholder

Similar activities

Prueba final BQ Bloque 2

Prueba final BQ Bloque 2

Professional Development

20 Qs

Mathematics and Computer Science Quizzz

Mathematics and Computer Science Quizzz

KG - Professional Development

19 Qs

W/S Calculation & science  Estimation & Costing

W/S Calculation & science Estimation & Costing

Professional Development

25 Qs

NEC branch Circuits

NEC branch Circuits

Professional Development

15 Qs

De todo

De todo

1st Grade - Professional Development

16 Qs

Topologia de redes y tipos de redes

Topologia de redes y tipos de redes

1st Grade - Professional Development

15 Qs

Ejercicios de problemas de funciones trigonométricas

Ejercicios de problemas de funciones trigonométricas

Professional Development

17 Qs

GB.LV.1.1

GB.LV.1.1

Professional Development

15 Qs

Electrical Cable Knowledge Quiz

Electrical Cable Knowledge Quiz

Assessment

Quiz

Mathematics

Professional Development

Hard

Created by

yusuf Abubakar

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What do you mean by 3 x 1c 300Al XLPE 11KV in a single line diagram?

3 times 1 centimetre 300 amps line, unearthed cable

3 core plus 1 core 300 amps lead sheathed 11KV cable

3 core 300 mm square copper sheathed 11KV cable

3 single core 300 mm square aluminium sheathed 11000V cable

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What you mean by ‘phasing out’ term in jointing cables would be?

A system to ensure safe isolation

The replacement of old colour markings with new ones

The location of high resistance joints

A method of ensuring correct phase rotation

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Cable spiking is used for

Ensuring a cable is dead at the point of work

Prove a cable is live and still in service

Ensure no current surges are present

Ensure no voltage surges are present

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An expansion joint is used in some types of high voltage underground cable to the counteract the effect of

Excessive oil pressure

Load surges

Increased loading

Subsidence

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When handling cold pour resins the mandatory PPE would be

Overalls and eye protection

Disposable gloves and breathing apparatus

Breathing apparatus and overall

Eye protection and disposable gloves

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The instrument used for synchronisation would be.

Earth impedance tester

Insulation resistance tester

Multi-meter

Test-lamp

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The full form of PILCSWA in Underground cables refers to

Plastic insulated lead covered steel wire armoured cable

Plastic insulated laminated copper steel wire armoured cable

Paper insulated lead covered steel wire armoured cable

Paper insulated lead conductor steel wire armoured cable

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?