1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the primary goal during the start-up phase of a distillation unit?
Ensure steady-state operation.
Increase temperature rapidly.
Maintain constant reflux ratio.
Stop feed flow intermittently.
Operate without monitoring pressure.
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
During the start-up of a catalytic cracker, why is it essential to preheat the catalyst bed?
To achieve the required reaction temperature.
To cool down the system.
To remove contaminants.
To increase feedstock viscosity.
To promote rapid shutdown.
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Why is inert gas used during the initial phase of starting oil refining equipment?
To prevent explosion due to residual hydrocarbons.
To increase oxygen concentration.
To accelerate reaction rates.
To reduce feedstock flow rate.
To enhance fouling of heat exchangers.
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the correct sequence for starting a hydrotreater?
Purging → Catalyst activation → Feed introduction.
Feed introduction → Purging → Cooling.
Heating → Feedstock mixing → Shutdown.
Cooling → Product collection → Catalyst regeneration.
Steam purging → Cooling → Final adjustment.
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the critical parameter to monitor during the start-up of a thermal cracking unit?
Furnace temperature.
Product storage capacity.
Maintenance schedule.
Laboratory test results.
Feed temperature.
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the first step in shutting down a distillation column?
Stop the feed flow.
Turn off the reboiler.
Disconnect utility lines.
Isolate the reflux drum.
Drain the column contents.
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
In a gas compressor system, what should be done to prevent backflow during shutdown?
Close the discharge valve immediately.
Open the suction valve completely.
Increase compressor speed briefly.
Shut down without adjusting valves.
Flush the system with water.