MULTIPLE CHOICE QUESTION

30 sec • 1 pt

1. Split-systems ______________ by Type I technicians.

may be serviced with 10 lbs. or less of refrigerant

may be serviced with 5 lbs. or less of refrigerant

may not be serviced

are exempt from EPA restrictions

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When converting a system to use a different refrigerant, only EPA-approved substitutes can be used. The following "drop-in" refrigerant is currently approved:

CFC

HFC

HFO

EPA does not approve any substitute refrigerants as a direct drop-in replacement

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Persons who open or perform maintenance, service, or repair of Type I appliances containing a CFC, HCFC, or HFC, can use ______________.

self-contained (active) recovery equipment

(passive) system dependent recovery equipment

either self-contained (active) or (passive) system dependent recovery equipment

only OSHA approved equipment

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

System-dependent (passive) recovery equipment use for an appliance containing HCFCs or HFCs is limited to a maximum charge of ____________ of refrigerant.

1 lb.

3 lbs.

5 lbs.

15 lbs.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Self-contained recovery devices, for use with small appliances containing CFCs, HCFCs, HFCs, and HFOs, must be able to recover _______ of the refrigerant when the compressor is operating.

75%

80%

90%

100%

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Self-contained recovery devices, for use with small appliances containing CFCs, HCFCs, HFCs, and HFOs, must be able to recover _______ of the refrigerant when the compressor is inoperative.

75%

80%

90%

100%

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When filling a charging cylinder with a regulated refrigerant, the refrigerant that is vented off the top ______________.

must be recovered

may be vented

is considered a de-minimis release and is not considered unlawful

can be put in a mixed refrigerant recovery cylinder

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Microsoft

Continue with Microsoft

or continue with

Facebook

Facebook

Apple

Apple

Others

Others

Already have an account?