Refrigeration System Quiz

Refrigeration System Quiz

University

15 Qs

quiz-placeholder

Similar activities

Citing Sources

Citing Sources

8th Grade - University

15 Qs

MEAL Training Mars Cocoa

MEAL Training Mars Cocoa

University

15 Qs

Shock #1

Shock #1

University

15 Qs

ielts 5.5 - HOW TO SPOT A LIAR

ielts 5.5 - HOW TO SPOT A LIAR

1st Grade - University

17 Qs

ENGLISH 104 Q1

ENGLISH 104 Q1

University

20 Qs

Terms you should know

Terms you should know

University

11 Qs

Citing Sources

Citing Sources

University

15 Qs

HVAC Skills and Knowledge

HVAC Skills and Knowledge

University

20 Qs

Refrigeration System Quiz

Refrigeration System Quiz

Assessment

Quiz

English

University

Hard

Created by

Laura McHugh

FREE Resource

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A refrigeration system uses a reciprocating compressor that operates at 1,750 RPM and has a cylinder displacement of 5 cubic inches per stroke. If it has 4 cylinders and completes 2 strokes per revolution, what is the total displacement per minute?

35,000 in³/min

70,000 in³/min

140,000 in³/min

280,000 in³/min

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A walk-in freezer operates with a suction pressure of 18 psig using R-404A. What is the approximate evaporator temperature?

-10°F

-20°F

-30°F

-40°F

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If a system has a superheat of 5°F and a subcooling of 3°F, what does this indicate?

The system is undercharged

The system is overcharged

The charge is nearly correct

The TXV is stuck closed

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A refrigeration system shows signs of liquid refrigerant returning to the compressor. What could be the cause?

TXV stuck open

Low superheat setting

Oversized metering device

All of the above

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A heat pump operating in heating mode has an outdoor temperature of 35°F and a suction line temperature of 50°F. What is the system’s superheat?

5°F

10°F

15°F

20°F

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A refrigeration system operates with a head pressure of 260 psig and a liquid line temperature of 100°F using R-134a. What is the approximate subcooling?

5°F

10°F

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A system has excessive discharge temperatures. What are possible causes?

Low refrigerant charge

High compression ratio

Insufficient condenser cooling

All of the above

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?