Electricity Unit 14 Review

Electricity Unit 14 Review

Professional Development

21 Qs

quiz-placeholder

Similar activities

Central heating components

Central heating components

Professional Development

20 Qs

EES-101 Unit 2- Electrical Quantities and Ohm’s Law

EES-101 Unit 2- Electrical Quantities and Ohm’s Law

Professional Development

24 Qs

Routine maintenance and running checks

Routine maintenance and running checks

Professional Development

25 Qs

HVT Day 2

HVT Day 2

Professional Development

16 Qs

November 2022

November 2022

Professional Development

25 Qs

Examen VCT Electrónica

Examen VCT Electrónica

Professional Development

20 Qs

Electrical Chapter 50

Electrical Chapter 50

Professional Development

20 Qs

Cooling systems

Cooling systems

Professional Development

20 Qs

Electricity Unit 14 Review

Electricity Unit 14 Review

Assessment

Quiz

Professional Development

Professional Development

Hard

Created by

Robert Hemmila

Used 3+ times

FREE Resource

21 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A heating and cooling system will operate properly using jumper wires to manually complete the control circuits at the low-voltage thermostat, but the system will not operate with the jumper wires removed, the _______________ is the likely cause of the malfunction.

Control transformer

Thermostat

Contactor

Control wiring

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A motor with a rating of 15 full load amps is protected by a line voltage overload that keeps opening at a current draw of 14 amps, indicating the overload is ___________.

Good

Shorted

Weak

Too large for the motor

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A reading of line voltage across the contacts of a sequencer indicates the contacts are _______________.

Open

Shorted

Closed

None of the choices are correct

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An electric heating system controlled by a sequencer is not heating. If the technician reads 240 volts across each contact of the sequencer and zero volts across the sequencer element, which of the following is likely the cause of the malfunction?

The sequencer contacts are stuck open

The thermostat is not sending 24 volts to the sequencer element

The sequencer element is open

The sequencer contacts are stuck closed

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

For a technician to determine if a pressure switch is faulty, the technician needs to know __________________.

The function of the pressure switch

The pressure settings of the switch

The pressure in the refrigeration system

All of the choices are correct

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Motors are very important loads in heating, cooling, and refrigeration equipment because they are used to rotate ___________________.

Fans

Compressors

Pumps

All of the choices are correct

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The internal overload used on most modern single-phase hermetic compressors is in the _____________ terminal of the motor.

Common

Run

Start

All of the choices are correct