
Plumbing and Heating MCQ Quiz 9289 Ph2 Pt2
Authored by Ian Marriott
Other
Professional Development
Used 8+ times

AI Actions
Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...
Content View
Student View
23 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
A customer has complained about lukewarm water coming from the cold tap. On close examination by an operative, it is clear that the hot water storage system is unvented. What is the cause of the problem and how would it be resolved?
Back pressure has occurred because the check valve has failed, allowing the hot water to expand in the pipe. The check valve will need to be replaced.
The expansion vessel is undersized, meaning that expansion must have taken place within the cold water system. A correctly sized expansion vessel will need to be installed.
Back siphonage has occurred; this happens when the tap is opened too quickly, causing negative pressure. An anti-vac valve will need to be installed.
The seating on the pressure release valve has become stuck, preventing pressure from leaving the system. The relief valve will need to be cleaned or replaced.
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Which risk category permits only an air gap to act as protection against contaminating the mains water supply?
Category 2
Category 3
Category 4
Category 5
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What backflow prevention should be used on a washbasin where the tap outlets are below the spillover level?
Single check valve.
Inline pipe interrupter.
Reduced pressure zone.
Double check valve.
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is a disadvantage of a gas-fired gravity hot water and pumped heating system?
The heating cannot be operated independently from the hot water.
The system requires a higher volume of water to operate hot water and heating efficiently.
The hot water cannot be operated independently from the heating.
The system lacks temperature controls which causes both hot water and heating to overheat.
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the minimum size of pipework required on a pumped heating gravity hot water system?
15 mm heating primary flow and return with 22 mm pipework used for the gravity hot water cylinder.
22 mm heating primary flow and return with 22 mm pipework used for the gravity hot water cylinder.
22 mm heating primary flow and return with 28 mm pipework used for the gravity hot water cylinder.
28 mm heating primary flow and return with 22 mm pipework used for the gravity hot water cylinder.
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What pipe sizes are used on a microbore system, including the size of the heating manifolds?
8 mm and 10 mm pipe connected to a 15 mm manifold.
10 mm and 15 mm pipe connected to a 15 mm manifold.
8 mm and 10 mm pipe connected to a 22 mm manifold.
10 mm and 15 mm pipe connected to a 22 mm manifold.
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Which boiler incorporates a diverter valve and a plate heat exchanger?
Back boiler.
Combination boiler.
Heat only boiler.
System boiler.
Access all questions and much more by creating a free account
Create resources
Host any resource
Get auto-graded reports

Continue with Google

Continue with Email

Continue with Classlink

Continue with Clever
or continue with

Microsoft
%20(1).png)
Apple
Others
Already have an account?