wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

6035 cold water revision

Total questions: 13

Worksheet time: 7mins

Name
Class
Date
1.

What is the maximum depth a water main service pipe should be laid at?

a)

750mm

b)

1,850mm

c)

1,350mm

d)

1,750mm

2.

Fluid category 1 represents:

a)

A serious health risk

b)

A significant health risk

c)

A slight health risk

d)

No health risk

3.

Which one of the following water

pipes connects the local main to the water undertaker’s stop valve?

a)

The distribution pipe

b)

The feed pipe

c)

The communication pipe

d)

The service pipe

4.

A cold water storage cistern base

must be supported:

a)

Over the whole of its base

b)

Over at least three bearers

c)

By using chipboard

d)

Over the majority of its base

5.

Which one of the following back flow

prevention devices must be

installed on a supply to a hose union bib tap, according to the Water Regulations?

a)

AUK 2 air gap

b)

Single check valve

c)

Fullway gate vale

d)

A double check valve

6.

The plastic medium density supply pipe, which is blue, is manufactured from which of the following materials?

a)

Polyethylene

b)

Polystyrene

c)

Polypropylene

d)

Polybutylene

7.

The Water Regulations state that a mixer tap which allows the hot and cold water to mix in the body of the tap with unbalanced pressures must have:

.

a)

Double check valve on both hot and cold supplies

b)

Single check valve of both hot and cold supplies

c)

AUK 3 air gap.

d)

AUK 2 air gap

8.

If a hand basin has submerged

taps, which one of the following back flow prevention devices does the

Water Regulations say must be

installed?

a)

Double check valve

b)

AUK 3 air gap.

c)

Overflow

d)

Single check valve

9.

When installing pipework in a

property, what must happen to all open-ended pipework if you leave the site?

a)

Capped off with push fit.

b)

Appliances must be fitted

c)

Left alone

d)

Labelled and taped

10.

Which one of the following can

affect the pressure and flow rates to the incoming main to a property?

a)

a. Peak demand periods

b)

The size of the CWSC in the loft

c)

The square metre floor area of the property

d)

How close the water meter is to the property

11.

The use of approved fittings,

WRAS approved, is because:

a)

They are legal and avoid contamination

b)

They are cheap and can be fitted easily

c)

They come with a longer warrantee than other fittings

d)

Their quality is not as good, but will work.

12.

According to the Water Regulations,

where must a drain-off valve be

placed?

a)

At every low point in the system

b)

At every high pressure point in the system

c)

At every high point in the system

d)

At every low pressure point in the system

13.

Which one of the following

connections to the CWSC must be

screened?

a)

Cold supply pipe

b)

Cold feed pipe

c)

Warning pipe

d)

Cold distribution pipe.