NEW
Font size
WorksheetsSterilization Protocols Post Test
Total questions: 10
Worksheet time: 5mins
Sterilization is a process that destroys or eliminates all forms of microbial life by physical or chemical methods.
True
False
The following can be said about Sterilization except
Sterilization must be performed on semi-critical equipment
Sterilization destroys all microorganisms on the surface of an item to prevent disease transmission
The two types of sterilization are High Temperature and Low Temperature
Sterilization requires the adherence to Standard Precautions and Safe Work Practices
The following can be said about Steam Sterilization
It is the most common form of high temperature sterilization
It is preferred for critical instruments that are not damaged by heat, steam, pressure or moisture
Examples of steam sterilizers include table top and gravity air displacement
All of the above
Critical devices or equipment that are sensitive to heat or moisture must undergo low temperature sterilization.
True
False
The following can be said about Low Temperature Sterilization
It uses either gas or vapor, or liquid immersion
It uses lengthier exposure times than other sterilization methods
It should only be used when direct contact of the material or substance with saturated steam is not possible
All of the above
Preparation and packaging is a vital component of the sterilization process. Items must be placed in materials and containers that are _________ the sterilization process
the same size as
compatible with
tougher than
flexible with
The following can be said about Sterilization/Process indicators
Sterilization Indicators are used to determine whether an item has been properly exposed to the sterilization process
There are three types of indicators used: physical, chemical and biological
Process indicators must be used in accordance to the method of sterilization
All of the above
Chemical indicators cannot verify sterility, but can be used to detect equipment malfunctions such as air leaks, inadequate temperature, wet steam, or work practice issues such as packaging errors.
True
False
Positive results from biological indicators only indicate the sterilization cycle delivered appropriate parameters, not that everything in the load is sterile.
True
False
When the sterilization process is complete, the following should be performed
Inspect sterile packages for integrity, and perform a check of physical, chemical and biological monitors
All sterilization quality assurance testing must be documented in the patient record
Sterile items should be transported in an open container for immediate use, or stored
All of the above
