wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Monitoring, Record Keeping, Compatibility and Tray assembly

Total questions: 55

Worksheet time: 24mins

Name
Class
Date
1.

what is this material called?

a)

Spongebob Mindblown Spongebob

b)

Spunbond Meltblown Spunbond

c)

Kraft paper

d)

Polyolefin

2.

what sterilization methods is this material compatible with?

a)

Steam and EtO only

b)

Steam and hydrogen peroxide only

c)

all wet and low temp processes

d)

steam, EtO, hydrogen peroxide, ozone

3.

what wrapping method is used on this item?

a)

burrito fold

b)

square fold

c)

envelope fold

d)

x-mas fold

4.

this wrap material is

a)

reusable

b)

disposable

5.

This muslin wrap is disposable

a)

True

b)

False

6.

This muslin wrap needs to be inspected for holes and patched if necessary

a)

True

b)

False

7.

This muslin wrap is compatible with hydrogen peroxide and ozone

a)

True, it is the best choice

b)

False, it will absorb the sterilant same as paper

8.

This is a

a)

Rigid container

b)

Semi-rigid container

c)

wrapped set

d)

C'mon Mr J. Seriously?

9.

Rigid containers are compatible with all processes

a)

True, but paper filters are not.

b)

False, only steam

c)

True without exceptions

d)

False, only for low temp because it will melt in steam

10.

This Rigid container does not need to be inspected for damage before each use

a)

False

b)

True

11.

This type 5 indicator indicates that it has been exposed to the parameters for sterilization

a)

No, but close

b)

Yes

c)

What's a parameter?

12.

This is a type _____ indicator and a _______.

a)

two, external indicator

b)

one, internal indicator

c)

5, external indicator

d)

one, tamper evident seal

13.

This type 5 indicator is for use in

a)

steam and EtO

b)

steam cycles

c)

Ozone and EtO

d)

all sterilization methods

14.

Polyolefin is compatible with

a)

all sterilization methods

b)

high temperature steam and EtO

c)

Low temperature methods including hydrogen peroxide, ozone and EtO

d)

ozone only

15.

Object that simulates a predetermined set of conditions when used to test sterilizing agents

a)

Process Challenge Device (PCD)

b)

Tamper Evident Seal

c)

Muslin

d)

Latching Mechanism

16.

Because it presents a potential risk to patients the FDA classifies sterilization packaging as a ________ medical device

a)

Class III

b)

Class I

c)

Class IV

d)

Class II

17.

Cellulose in paper will absorb these sterilants and cause the sterilizer to abort the cycle

a)

steam and EtO

b)

hydrogen peroxide (H2O2) and ozone (O3)

c)

ethylene oxide and ozone

d)

peracetic acid and H2O2

18.

As a sterile packaging material, canvas is

a)

preferred

b)

not acceptable

c)

used only for steam

d)

only for low temp

19.

Some rigid container systems do not have tamper evident seals

a)

True

b)

False

20.

Medical grade paper used for packaging

a)

Graph paper

b)

SMS

c)

Kraft paper

d)

Polyolefin

21.

A substitute for paper in low temp processes

a)

Cellulose

b)

Polyolefin

c)

Kraft

d)

Crepe

22.

Instrument tips should curve to the stronger side of a peel pack

a)

Yes, the plastic side

b)

No, the plastic side

c)

Yes, the paper side

d)

No, the paper side

23.

When double pouching you should fold the inner pouch to make it fit

a)

True

b)

False

24.

A wrap method which creates a package within a package

a)

Sequential

b)

Simultaneous

c)

Square

d)

Envelope

25.

Masking tape for a package closure is considered a best practice

a)

True

b)

False

26.

Safety pins and staples should not be used as package closures because they create holes which makes a passage for bacteria

a)

True

b)

False

27.

Packaging should be performed by the user department since they know their own instruments best

a)

True

b)

False

28.

An item is considered sterile unless its packaging is compromised

a)

Time related sterility

b)

Shelf life

c)

Use life

d)

Event related sterility

29.

Placing an item in a dust cover will extend the expiration date

a)

True

b)

False

30.

A tamper evident seal is

a)

Sealing method for sterile packaging that allows users to see if pack has been opened

b)

a water mammal that doesn't need your drama

c)

a class IV medical device

31.
muslin
a)
Term describing a variety of plain cotton or cotton blend fabrics
b)
used for low temp only
c)
less labor needed than disposable
d)
replaces rigid containers
32.
superheating
a)
Condition that arises when steam is at a temp that exceeds that of saturated steam at same temp
b)
the newest Avenger
c)
necessary for steam sterilization
d)
causes autoclave fires
33.

wet pack

a)

Container with moisture after sterilization is complete

b)

a pack that is less undry than an unwetter pack

34.

kraft paper

a)

Medical grade paper packaging material

b)

available at Hobby Lobby in the Hospital supplies department

35.

wicking material

a)

an approved absorbant material that allows steam penetration and facilitates drying

b)

the same as a rigid container

36.

time related sterility

a)

a package is considered sterile until an expiration date

b)

a package is sterile until the clock strikes midnight

c)

a package is sterile until it is opened for use

37.

event related sterility

a)

a package is considered sterile until its integrity has been compromised

b)

a package is sterile until a certain date

c)

a package is sterile until it is opened for use

38.

class 5 integrator

a)

integrating indicator designed to monitor all parameters

b)

a class 2 processed with a BI

39.

process indicators

a)

devices for use with individual units to demonstrate that the unit has been exposed to the sterilization process

b)

are not available for certain gravity cycles

40.

chemical indicators

a)

systems that reveal a change in one or more predefined parameters on the basis of a chemical or physical change resulting from exposure to a process

b)

indicate the presence of toxic chemicals

41.

load control number

a)

label information on packages that identifies the sterilizer, cycle run and date of sterilization

b)

optional tracking method for steam sterilization

42.
All sterilization methods have sterility indicators.
a)
true
b)
false
43.

Sterilization packaging is classified as a _______.

a)

FDA Class II medical device

b)

Spaulding Class I medical device

c)

Maintenance Indicator

d)

A big stinking ball of garbage

44.

Used to allow air removal, steam penetration and to facilitate drying.

a)

Wicking Material

b)

Gauze squares

c)

SMS

d)

Hydrogen Barrier

45.

Unlock the handles and open the instruments when_________.

a)

Placing them on a stringer

b)

the IFU indicates an SFPP cycle

c)

placing them on stringer in alphabetical order

d)

in the witness protection program

46.
Which sterilizer test uses bacterial spores?
a)
BI
b)
CI
c)
GI
d)
Magnum PI
47.
Kraft type paper can be used in_______.
a)
Steam and EtO
b)
Steam and H2O2
c)
H2O2 and EtO
d)
O3 and steam
48.
30% to 60%
a)
relative humidy range for SPD
b)
how many racks of ribs can we fit into this autoclave
c)
the temperature of sterile processing
d)
the steam saturation on a pre-vac cycle
49.

record keeping is

a)

fun

b)

mandatory

c)

lame

d)

optional

50.

tasks performed by CS techs require specific

a)

time

b)

knowledge and skills

c)

time and temp

d)

work and monitoring

51.

every load containing implants should be monitored with a PCD containing

a)

a type 5 CI

b)

a BI and a type 5 CI

c)

a BI and a type 6 CI

d)

a BI and a type 4 CI

52.

a BI that does not go through the sterilization process

a)

monitor

b)

type 6

c)

control

d)

bacillus atrophaeus

53.

Wicking materials are used to

a)

allow air removal, steam penetration and facilitate drying

b)

dry instruments before sterilization

c)

allow hydrogen peroxide penetration

d)

aid in the aeration of EtO cycles

54.

the most common wrap style is

a)

the west coast style

b)

square fold

c)

the peel pouch

d)

the envelope fold

55.

internal CI's _______ prove sterility

a)

may not

b)

do not

c)

usually will

d)

always