WorksheetsFIRE PRO SEMINAR SERIES
Total questions: 45
Worksheet time: 23mins
WHAT IS NFPA
National Fire Protection Association
National Fire Protection Assessment
National Fire Philippine Association
National Fire Protection Acadamy
NFPA 13
Standard for the Installation of Standpipe and Hose Systems
Standard for Water Tanks for Private Fire Protection
Standard for the Installation of Sprinkler Systems
Standard for the Installation of Foam-Water Sprinkler and Foam Water Spray
It is the rapid oxidation of a material in the exothermic chemical process of combustion, releasing heat, light, and various reaction products.
Fire
Water
Oil
Heat
Classification of Fire that involves energized electrical equipment
Class A
Class B
Class C
Class D
Type of Fire Protection System that Compartmentalize the fire room or space to control the fire spread.
Active Fire Protection System
Passive Fire Protection System
Preventive Fire Protection System
Automated Fire Protection System
A fire suppression or control device that operates automatically when its heat activated element is heated to its thermal rating or above, allowing water to discharge over a specified area.
Automatic Sprinkler
Fire Extinguisher
Fire Hose
Strobe Light
Sharply reducing the heat release rate of a fire and preventing its regrowth by means of direct and sufficient application of water through the fire plume to the burning fuel surface.
Fire Prevention
Fire Protection
Fire Suppression
Fire Detection
A device designed for the purpose of reducing, regulating, controlling, or restricting water pressure. Examples include pressure reducing valves, pressure control valves, and pressure restricting devices.
Pressure Regulating Device
Pressure Restricting Device
Hydrostatic Test
Flushing Test
Shall be defined as occupancies or portions of other occupancies where combustibility is low, quantity of combustibles is moderate, stockpiles of combustibles do not exceed 8 ft (2.4m), and fires with moderate rates of heat release are expected.
Ordinary Hazard Group 1
Ordinary Hazard Group 2
Ordinary Hazard Group 3
Ordinary Hazard Group 4
A ________ is a part of a fire sprinkler system's water supply and powered by electric or diesel.
fire pump
fire extinguisher
fire sprinkler
fire cabinet
The BUREAU OF FIRE PROTECTION was created by virtue of?
RA 6977
RA 6975
RA 6957
RA 6675
Automatic Sprinkle design shall be in accordance with NFPA 20, Standard for the Installation of Sprinkler System.
TRUE
FALSE
required where energized electrical equipment can be encountered that would require a non conducting extinguishing medium.
Fire extinguishers with Class A
Fire extinguishers with Class B
Fire extinguishers with Class C
None of the above
defined as occupancies or portions of other occupancies where the quantity and/or combustibility of contents is low and fires with relatively low rates of heat release are expected.
Light hazard
Ordinary hazard (Group 1)
Ordinary hazard (Group 2)
Extra hazard (Group 1)
an enclosure where, under normal circumstances, persons are present.
Normally Unoccupied
Abnormally Unoccupied
Abnormally Occupied
Normally Occupied
Any liquid having a flash point at or above thirty seven and eight tenths degrees Celsius (37.8°C)
Flammable Liquid
Combustible Liquid
Flammable Solid
Combustible Solid
A test performed by the flow and measurement of water from one hydrant and the static and residual pressures from an adjacent hydrant for the purpose of determining the available water supply at that location.
Flow Test
Flushing Test
Hydrostatic Test
All of the Above
A test of a piping system using high velocity flows to remove debris from the piping system prior to it being placed in service.
Flow Test
Flushing Test
Hydrostatic Test
All of the above
A test of a closed piping system and its attached appurtenances consisting of subjecting the piping to an increased internal pressure for a specified period of duration to verify system integrity and leak rates
Flow Test
Flushing Test
Hydrostatic Test
All of the Above
This standard provides the minimum requirements for the design, construction, installation, and maintenance of tanks and accessory equipment that supply water for private fire protection.
NFPA 13
NFPA 72
NFPA 70
NFPA 22
An American organization that write and establish standard for fire protection:
PSME
BFP
NFPA
DepEd
1. An Act ESTABLISHING A COMPREHENSIVE FIRE CODE OF THE PHILIPPINES is:
PD 1185
RA 9514
RA 6678
PD 2020
1. What documents issued to Fire Volunteers, Fire Volunteer Organizations and Fire Safety Practitioners after completion of the mandatory training and competency evaluation conducted by the BFP?
NCII
COC
CEM
FSEC
The actual reading on a gage, does not account for atmospheric pressure
Gauge Pressure
Atmospheric Pressure
Absolute Pressure
Working Pressure
1. A type of fire involving cooking oils or fats is:
Class A
Class B
Class C
Class K
What is the NFPA Standard for the Installation of Private Fire Service Mains and Their Appurtenances?
NFPA 13
NFPA 14
NFPA 20
NFPA 24
A fire protection system that take direct physical action to reduce the growth rate of fire or the migration of smoke and intended to extinguish or control the fire is:
Water-based fire protection system
Fire Detection and Alarm System
Passive Fire protection System
Active Fire Protection system
A type of fire involving flammable or combustible liquid or gaseous fuels is:
Class A
Class B
Class D
Class C
A type of fire that occur when a solid, organic material such as wood, cloth, rubber, or some plastics become heated to their flash point and ignite is:
Class A
Class B
Class C
Class D
An integrated system of underground and overhead piping designed in accordance with fire protection engineering standards is:
Fire Pump
Private Fire Service Main
Sprinkler System
Fire Hydrant System
An alarm devices use to detect a pressure increase or decrease in sprinkler system is:
Pressure Gauge
Water Flow Detector
Supervisory Switch
Pressure Switch
A sprinkler system employing automatic sprinklers attached to a piping system containing water and connected to a water supply so that water discharges immediately from sprinklers opened by heat from a fire is:
Wet Pipe
Dry Pipe
Preaction
Deluge
A sprinkler system recommended to prevent water damage due to mechanical damage to system piping is:
Wet Pipe
Dry Pipe
Preaction
Deluge
A pump connected to a fire sprinkler system and is intended to maintain pressure in a fire protection piping system is:
Fire Pump
Jockey Pump
Booster Pump
Transfer Pump
A sprinkler component that is hydraulically operated outdoor alarm designed for use with fire protection system waterflow detection valve is?
Sprinkler Heads
Alarm Check Valve
Pressure Switch
Water Motor Alarm
The heart of the control system. It contains the system’s central processing unit, power supply, and other primary components is:
Smoke Detector
Initiating Device
Notification Appliance
Control Panel
A standpipe system having piping containing water at all times is:
Wet Standpipe
Dry Standpipe
Sprinkler System
Fire Hose Cabinet
A sprinkler system recommended to prevent water damage due to mechanical damage to system piping is:
Wet Pipe
Dry Pipe
Preaction
Deluge
Where the suction pipe and pump suction flange are not of the same size, they shall be connected with what type of fitting:
Flange
Elbow
Concentric Reducer
Eccentric Reducer
A fire alarm system component that provides audible, tactile, or visible output, or any combination thereof is:
Sprinkler System
Initiating Devices
Notification Appliances
Fire Alarm System
A type of fire alarm system used to indicate the location of a fire on a zone basis is:
Conventional
Addressable
Class A
Class B
Who officially developed and used sprinkler heads in 1874 to protect his piano factory?
Henry Parmalee
John Carey
Colonel William Congreve
Engr. Janice Bayas
A wet pipe sprinkler components designed to automatically actuate electrically and/or hydraulically operated alarms when there is a steady flow of water into the system which is equivalent to discharge rate of one or more sprinklers is:
Sprinkler Heads
Alarm Check Valve
Pressure Switch
Water Motor Alarm
What is the NFPA Standard for the Installation of Private Fire Service Mains and Their Appurtenances
NFPA 14
NFPA 13
NFPA 20
NFPA 24
A type of centrifugal pump that is characterized by a housing that is split parallel to the shaft is:
Vertical Turbine Fire Pump
Horizontal Slip-case Fire Pump
End-suction Fire Pump
Vertical In-line Fire Pump