FIRE PRO SEMINAR SERIES

Total questions: 45

Worksheet time: 23mins

Name
Class
Date
1.

WHAT IS NFPA

a)

National Fire Protection Association

b)

National Fire Protection Assessment

c)

National Fire Philippine Association

d)

National Fire Protection Acadamy

2.

NFPA 13

a)

Standard for the Installation of Standpipe and Hose Systems

b)

Standard for Water Tanks for Private Fire Protection

c)

Standard for the Installation of Sprinkler Systems

d)

Standard for the Installation of Foam-Water Sprinkler and Foam Water Spray

3.

It is the rapid oxidation of a material in the exothermic chemical process of combustion, releasing heat, light, and various reaction products.

a)

Fire

b)

Water

c)

Oil

d)

Heat

4.

Classification of Fire that involves energized electrical equipment

a)

Class A

b)

Class B

c)

Class C

d)

Class D

5.

Type of Fire Protection System that Compartmentalize the fire room or space to control the fire spread.

a)

Active Fire Protection System

b)

Passive Fire Protection System

c)

Preventive Fire Protection System

d)

Automated Fire Protection System

6.

A fire suppression or control device that operates automatically when its heat activated element is heated to its thermal rating or above, allowing water to discharge over a specified area.

a)

Automatic Sprinkler

b)

Fire Extinguisher

c)

Fire Hose

d)

Strobe Light

7.

Sharply reducing the heat release rate of a fire and preventing its regrowth by means of direct and sufficient application of water through the fire plume to the burning fuel surface.

a)

Fire Prevention

b)

Fire Protection

c)

Fire Suppression

d)

Fire Detection

8.

A device designed for the purpose of reducing, regulating, controlling, or restricting water pressure. Examples include pressure reducing valves, pressure control valves, and pressure restricting devices.

a)

Pressure Regulating Device

b)

Pressure Restricting Device

c)

Hydrostatic Test

d)

Flushing Test

9.

Shall be defined as occupancies or portions of other occupancies where combustibility is low, quantity of combustibles is moderate, stockpiles of combustibles do not exceed 8 ft (2.4m), and fires with moderate rates of heat release are expected.

a)

Ordinary Hazard Group 1

b)

Ordinary Hazard Group 2

c)

Ordinary Hazard Group 3

d)

Ordinary Hazard Group 4

10.

A ________ is a part of a fire sprinkler system's water supply and powered by electric or diesel.

a)

fire pump

b)

fire extinguisher

c)

fire sprinkler

d)

fire cabinet

11.

The BUREAU OF FIRE PROTECTION was created by virtue of?

a)

RA 6977

b)

RA 6975

c)

RA 6957

d)

RA 6675

12.

Automatic Sprinkle design shall be in accordance with NFPA 20, Standard for the Installation of Sprinkler System.

a)

TRUE

b)

FALSE

13.

required where energized electrical equipment can be encountered that would require a non conducting extinguishing medium.

a)

Fire extinguishers with Class A

b)

Fire extinguishers with Class B

c)

Fire extinguishers with Class C

d)

None of the above

14.

defined as occupancies or portions of other occupancies where the quantity and/or combustibility of contents is low and fires with relatively low rates of heat release are expected.

a)

Light hazard

b)

Ordinary hazard (Group 1)

c)

Ordinary hazard (Group 2)

d)

Extra hazard (Group 1)

15.

an enclosure where, under normal circumstances, persons are present.

a)

Normally Unoccupied

b)

Abnormally Unoccupied

c)

Abnormally Occupied

d)

Normally Occupied

16.

Any liquid having a flash point at or above thirty seven and eight tenths degrees Celsius (37.8°C)

a)

Flammable Liquid

b)

Combustible Liquid

c)

Flammable Solid

d)

Combustible Solid

17.

A test performed by the flow and measurement of water from one hydrant and the static and residual pressures from an adjacent hydrant for the purpose of determining the available water supply at that location.

a)

Flow Test

b)

Flushing Test

c)

Hydrostatic Test

d)

All of the Above

18.

A test of a piping system using high velocity flows to remove debris from the piping system prior to it being placed in service.

a)

Flow Test

b)

Flushing Test

c)

Hydrostatic Test

d)

All of the above

19.

A test of a closed piping system and its attached appurtenances consisting of subjecting the piping to an increased internal pressure for a specified period of duration to verify system integrity and leak rates

a)

Flow Test

b)

Flushing Test

c)

Hydrostatic Test

d)

All of the Above

20.

This standard provides the minimum requirements for the design, construction, installation, and maintenance of tanks and accessory equipment that supply water for private fire protection.

a)

NFPA 13

b)

NFPA 72

c)

NFPA 70

d)

NFPA 22

21.

An American organization that write and establish standard for fire protection:

a)

PSME

b)

BFP

c)

NFPA

d)

DepEd

22.

1. An Act ESTABLISHING A COMPREHENSIVE FIRE CODE OF THE PHILIPPINES is:

a)

PD 1185

b)

RA 9514

c)

RA 6678

d)

PD 2020

23.

1. What documents issued to Fire Volunteers, Fire Volunteer Organizations and Fire Safety Practitioners after completion of the mandatory training and competency evaluation conducted by the BFP?

a)

NCII

b)

COC

c)

CEM

d)

FSEC

24.

The actual reading on a gage, does not account for atmospheric pressure

a)

Gauge Pressure

b)

Atmospheric Pressure

c)

Absolute Pressure

d)

Working Pressure

25.

1. A type of fire involving cooking oils or fats is:

a)

Class A

b)

Class B

c)

Class C

d)

Class K

26.

What is the NFPA Standard for the Installation of Private Fire Service Mains and Their Appurtenances?

a)

NFPA 13

b)

NFPA 14

c)

NFPA 20

d)

NFPA 24

27.

A fire protection system that take direct physical action to reduce the growth rate of fire or the migration of smoke and intended to extinguish or control the fire is:

a)

Water-based fire protection system

b)

Fire Detection and Alarm System

c)

Passive Fire protection System

d)

Active Fire Protection system

28.

A type of fire involving flammable or combustible liquid or gaseous fuels is:

a)

Class A

b)

Class B

c)

Class D

d)

Class C

29.

A type of fire that occur when a solid, organic material such as wood, cloth, rubber, or some plastics become heated to their flash point and ignite is:

a)

Class A

b)

Class B

c)

Class C

d)

Class D

30.

An integrated system of underground and overhead piping designed in accordance with fire protection engineering standards is:

a)

Fire Pump

b)

Private Fire Service Main

c)

Sprinkler System

d)

Fire Hydrant System

31.

An alarm devices use to detect a pressure increase or decrease in sprinkler system is:

a)

Pressure Gauge

b)

Water Flow Detector

c)

Supervisory Switch

d)

Pressure Switch

32.

A sprinkler system employing automatic sprinklers attached to a piping system containing water and connected to a water supply so that water discharges immediately from sprinklers opened by heat from a fire is:

a)

Wet Pipe

b)

Dry Pipe

c)

Preaction

d)

Deluge

33.

A sprinkler system recommended to prevent water damage due to mechanical damage to system piping is:

a)

Wet Pipe

b)

Dry Pipe

c)

Preaction

d)

Deluge

34.

A pump connected to a fire sprinkler system and is intended to maintain pressure in a fire protection piping system is:

a)

Fire Pump

b)

Jockey Pump

c)

Booster Pump

d)

Transfer Pump

35.

A sprinkler component that is hydraulically operated outdoor alarm designed for use with fire protection system waterflow detection valve is?

a)

Sprinkler Heads

b)

Alarm Check Valve

c)

Pressure Switch

d)

Water Motor Alarm

36.

The heart of the control system. It contains the system’s central processing unit, power supply, and other primary components is:

a)

Smoke Detector

b)

Initiating Device

c)

Notification Appliance

d)

Control Panel

37.

A standpipe system having piping containing water at all times is:

a)

Wet Standpipe

b)

Dry Standpipe

c)

Sprinkler System

d)

Fire Hose Cabinet

38.

A sprinkler system recommended to prevent water damage due to mechanical damage to system piping is:

a)

Wet Pipe

b)

Dry Pipe

c)

Preaction

d)

Deluge

39.

Where the suction pipe and pump suction flange are not of the same size, they shall be connected with what type of fitting:

a)

Flange

b)

Elbow

c)

Concentric Reducer

d)

Eccentric Reducer

40.

A fire alarm system component that provides audible, tactile, or visible output, or any combination thereof is:

a)

Sprinkler System

b)

Initiating Devices

c)

Notification Appliances

d)

Fire Alarm System

41.

A type of fire alarm system used to indicate the location of a fire on a zone basis is:

a)

Conventional

b)

Addressable

c)

Class A

d)

Class B

42.

Who officially developed and used sprinkler heads in 1874 to protect his piano factory?

a)

Henry Parmalee

b)

John Carey

c)

Colonel William Congreve

d)

Engr. Janice Bayas

43.

A wet pipe sprinkler components designed to automatically actuate electrically and/or hydraulically operated alarms when there is a steady flow of water into the system which is equivalent to discharge rate of one or more sprinklers is:

a)

Sprinkler Heads

b)

Alarm Check Valve

c)

Pressure Switch

d)

Water Motor Alarm

44.

What is the NFPA Standard for the Installation of Private Fire Service Mains and Their Appurtenances

a)

NFPA 14

b)

NFPA 13

c)

NFPA 20

d)

NFPA 24

45.

A type of centrifugal pump that is characterized by a housing that is split parallel to the shaft is:

a)

Vertical Turbine Fire Pump

b)

Horizontal Slip-case Fire Pump

c)

End-suction Fire Pump

d)

Vertical In-line Fire Pump