wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

DH Digital Imaging

Total questions: 19

Worksheet time: 10mins

Name
Class
Date
1.

It is part of the professional's responsibility to thoroughly explain the reason dental images are needed and encourage patients to have images taken when it is deemed necessary.

a)

True

b)

False

2.

In our clinic, students are allowed 1 retake for extra oral images. They are allowed 2 retakes for a full mouth series done with digital sensors.

a)

both statements are true

b)

first is true and second is false

c)

first is false and second is true

d)

both statements are false

3.

An example of direct imaging is a PSP. An example of indirect imaging is digital sensor.

a)

both statements are true

b)

first is true and second is false

c)

first is false and second is true

d)

both statements are false

4.

What kinds of imaging can be done with a NOMAD Pro 2?

A) digital sensor

B) PSP

C) analog

a)

A only

b)

B only

c)

C only

d)

A & B

e)

all of the above

5.

__________ means to reverse the grey scale as an image is viewed (radiolucent to radiopaque, and vice versa).

a)

digital imaging

b)

digital subtraction

c)

digitize

d)

analog image

6.

_______ is a solid-state silicon chip detector that converts light or x-ray photons into an electrical charge or signal. It is found in the sensor.

a)

analog image

b)

charge-coupled device (CCD)

c)

pixel

d)

storage phosphor imaging

7.

_____ is a discrete unit of information. Digital information is contained in, and presented as, discrete units of information (also called picture element).

a)

voxel

b)

sensor

c)

analog image

d)

pixel

8.

How does radiation exposure of CBCT compare to FMS?

a)

equivalent to 3-4 FMS

b)

equivalent to 4-5 FMS

c)

less than that of 3-4 FMS

d)

less than that of 4-5 FMS

9.

What does CBCT stand for?

a)

cone beam calculated topography

b)

cone beam computed topography

c)

cone beam computed tomography

d)

computed beam cone tomography

10.

Some primary uses of CBCT include:

A) implants

B) TMJ evaluation

C) trauma

D) sinus evalutaion

a)

all of the above

b)

A, B, & C

c)

B, C & D

d)

A, C, & D

e)

A, B, & D

11.

To address infection control when doing digital imaging, you must make sure to cover the sensor or PSP with a sleeve. This is especially important because you cannot disinfect the sensors or PSP.

a)

both statements are true

b)

first is true and second is false

c)

first is false and second is true

d)

both statements are false.

12.

What are the two phases that CBCT is comprised of?

a)

data distribution

b)

data acquisition

c)

data reconstruction

d)

data configuration

13.

The first phase of CBCT involves an x-ray unit connected to an x-ray detector that circles the had of a patient producing 2D images. The second phase involves reconstructing those images into 3D information.

a)

both statements are true

b)

first is true and second is false

c)

first is false and second is true

d)

both statements are false

14.

FOV represents the area on to which the x-ray beam is projected.

a)

true

b)

false

15.

About what percentage of dental offices have moved to digital imaging?

a)

50-60

b)

60-70

c)

70-80

d)

80-90

16.

At what point do you need to put your mask on while exposing digital images?

a)

you don't need one

b)

you only need one when you are cleaning the room

c)

immediately prior to processing

d)

after washing your hands, before putting your gloves on.

17.

What types of image receptors are used in digital radiography?

A) charged-coupled device (CCD) sensor

B) complementary metal oxide semiconductor (CMOS)/active pixel sensor (APS)

C) photostimulable phosphor (PSP) plate

D) analog film

a)

all of the above

b)

A, B, & C

c)

A, B, & D

d)

A & B

e)

A & C

18.

Comparing PSP images to sensor images, the PSP images are lower resolution/quality when looking at line pairs per millimeter (lp/mm). PSPs can produce 15-20 lp/mm where sensors can produce 24 lp/mm at the maximum resolution settings.

a)

both statements are true

b)

first is true and second is false

c)

first is false and second is true

d)

both statements are false

19.

When working with PSP plates, after exposing the plate you need to use Scan-X to scan into Dexis. You must open Dentrix for patient information.

a)

both statements are true

b)

first is true and second is false

c)

first is false and second is true

d)

both statements are false