Font size
WorksheetsQuality Management quiz 2
Total questions: 20
Worksheet time: 12mins
Quality management consist of ......
Quality control
Quality assurance
Quality check-up
Quality of life
QC goals are....
minimize dose to machine
optimize image quality
establish baseline of machine
save energy
Quality assurance monitor....
proper patient scheduling
reception of patient
preparation of machine
image interpretation
10 steps QA program
Assign responsibility
Delineate scope of care.
Establish limits of the scope of assessment.
Communicate information to organization-wide quality assurance programs
Major Instrument And Qc Test Tool
Dose meter
Multi meter
beam allignment test tool
cassette
Which is TRUE about the device?
FILM CONGRUENCE experiment
BEAM ALIGNMENT experiment
linearity experiment
exposure reproducibility experiment
Which of the following is TRUE about this experiment
congruence less than 1 %
perpendicularity less than 2 degrees
leakage radiation
survey meter is not perpendicular
Name this toolbox......
multimeter
survey meter
collimator test tool
radiation leakage test tool
Describe step by step measurement of x-ray output.
collimate the x-ray field to the smallest reasonable size
perform measurement at the middle of the x-ray field
ensure leveling of the x-ray tube
off the x-ray machine
accuracy and linearity kV .....
kV affect the x-ray beam quality
kV affect the patient exposure
kV affect the motion artifact
kV affect the contrast density of film
LINEARITY kV means.....
sequential increases in mAs should produce the same sequential increase in the exposure measured.
increase dose
inversely proportion with mAs
purpose of accuracy and linearity test....
to determine constancy and linearity of radiation output
to determine the dose receive by patient
Which result of test is this?
leakage radiation test
reproducibility test
kVp linearity test
beam allignment test
Reproducibility of exposure is ...
A simple test which measures the ability of the multimeter to faithfully deliver the same output when the same mAs are used
A simple test which measures the ability of the x-ray generator to faithfully deliver the same kvp when the same mAs are used
A simple test which measures the ability of the x-ray generator to faithfully deliver the same output when the same exposure factors are used
Purpose of 'reproducibility of exposure test is'
To determine the variation in average mAs over a number of exposures at the same generator setting
To determine the variation in average kVp over a number of exposures at the same generator setting
In reproducibility test, which factor that is maintain..
kVp
mAs
output
Which of the following is TRUE about Focal spot test?
using pinhole camera
using star test pattern
using focal spot test tool
State the test.
Half value layer test
Linearity test
Accuracy test
Reproducibility test
State the thickness of aluminium for HVL test .
1mm
2mm
2.75 mm
3 mm
Do you want to be a QC personnel?
Yes
No