A stream of high-velocity temperature-controlled air which is directed downward, across an opening
AIR COMBUSTION
AIR CURTAIN
AIR TIGHT
AIR VENT
A device designed to stop an elevator car or counterweight from descending beyond its normal limit of travel
THREAD
TRACK
BUMPER
STRIP
When the elevator car rest on its fully compressed buffer, there shall be a vertical clearance of not less than between the pit floor and the lowest structural or mechanical part.
510 mm
810 mm
710 mm
610 mm
There shall be installed in the pit of each elevator where the pit extend more than ___ below the sill of the pit access door
660 mm
760 mm
560 mm
860 mm
Device for heating water or generating steam above atmospheric pressure.
EVAPORATOR
HEATER
BOILER
HUMIDIFIER
Machine that decreases the volume and increases the pressure of a quantity of air by mechanical means.
PUMPING MACHINE
AIR PUMP
COMPRESSOR
MECHANICAL PUMP
Device that convert electrical energy into mechanical energy, by electromagnetic means.
GENERATOR
ALTERNATOR
ADAPTER
COMPRESSOR
A machine often provides the most convenient and economical means of transporting relatively small articles between levels.
PASSENGER ELEVATOR
SERVICE ELEVATOR
GARBAGE SHUTE
DUMBWAITER
An air-conditioning system in which the air is treated by equipment at one or more central locations outside the spaces served and conveyed to and from these spaces by means of fans and pumps through duct and pipes.
CENTRALIZED AIRCON
DUCT AIRCON
GENERAL AIRCON
ROOM AIRCON
The following are elements of centralized air-conditioning system except _______.
Central Cooling
Gradual Cooling
Method of cooling
Natural Cooling
It is the flow of heat through a material by transfer from warmer to cooler molecules in contact with each other.
Conduction
Combustion
Connection
Contraction
What is also known as a synthetic chemical refrigerant?
OXIDANT
PLENUM
AMMONIA
FREON
A process which refrigerant from liquid to gas
friction
evaporator
combustion
subduction
The art and practice of heating and cooling with water
sedation
boiling
hydronics
effluent
A controller sensitive to the degree of moisture in the
air
Humidistat
Hygrostat
Humidifier
Hoistropes
Steel wires used to compensate cars and counterweights
cable
coil
relay
hoist-ropes
A device that is basically a double throw switch of
generally 3-pole connection that will automatically transfer
the power from the standby generator to the building
circuitry during electrical power failure.
Automatic Transfer Switch
Toggle Switch
Safety Switch
Tab Switch
The effective room temperature in air-conditioning.
78-84 ˚F /25-31 deg. C
58-64 ˚F /15-20 deg. C
68-74 ˚F /20-23 deg. C
88-98 ˚F /30-38 deg. C
Heat rating for a fixed temperature heat detector.
125-187˚F
135-197˚F
115-177˚F
125-157˚F
Which is the following characterizes centrallized airconditioning
a. It uses ducts
b. Has cooling tower
c. Provided with air handling unit
d. All of these
A & D
B & C
C & A
A, B, C, D,
The total cooling output of an air-conditioner during its annual usage, in BTU/hr divided by the energy input during the same period, in watt-hours is known as_____.
Seasonal energy efficiency ratio
Trans-ratio
Limit ratio
Proportional ratio
A factor used in calculating cooling load that includes heat
transferred from walls, doors, ceilings, etc. is known as _____.
Factor load
Loading ratio
Thermal load
Trans-load
Which type of refrigerant is recommended for residential,
commercial, and industrial application using split type air-conditioning system?
R-57
R-42
R-34
R-22
The term impedance is used in transformers and other devices in AC is a combination of _______.
Receive and deceive
Reaction and effect
Resistance and reactance
Inlet and outlet
Kind of glass required in an escalator's balustrade
DOUBLE GLAZING TYPE GLASS
TEMPERED TYPE GLASS
ANNEALED TYPE GLASS
LAMINATED TYPE GLASS
Minimum angle of inclination of an escalator
35 degrees
25 degrees
15 degrees
20 degrees
Minimum for window type AC installed on ground floors
2.50 meters
1.95 meters
2.13 meters
2.20 meters
Mechanical equipment coupled with a central air conditioning system used to dehumidify and cool the airstream injected to the conditioned space
CENTRAL UNIT
GEAR UNIT
MOTOR UNIT
FAN COIL UNIT
An assembly consisting of a pulley wheel, side plates, shaft, and bearings over which a cable or roped is passed.
Sheave
Thread
Gear
Track
Under NBC, the maximum rated speed of an escalator along the angle of travel.
28 Meters/Min
38 Meters/Min
18 Meters/Min
45 Meters/Min