1.

A structural system without complete vertical local carrying space frame

a)

Braced frame

b)

Bearing wall system

c)

Rigid component

d)

Concentric braced frame

2.

A component including its attachments having fundamental period less than or equal to 0.06 sec

a)

Braced frame

b)

Bearing wall system

c)

Rigid component

d)

Flexible component

3.

A component including its attachments having fundamental period greater than 0.60 sec

a)

Braced frame

b)

Bearing wall system

c)

Rigid component

d)

Flexible component

4.

A complete record of test of materials and of concrete shall be available for inspection during the progress of work and ____ years after completion of the project and shall be preserved by the inspecting engineer or architect for that purpose

a)

2 years

b)

5 years

c)

10 years

d)

15 years

5.

The minimum bend diameter for 10 mm Ø through 25 mm Ø bars

a)

12 db

b)

6 db

c)

8 db

d)

10 db

6.

The minimum bend diameter for 28 mm Ø through 36 mm Ø bars

a)

12 db

b)

6 db

c)

8 db

d)

10 db

7.

In spirally reinforced or tied reinforced compression members, clear distance between longitudinal bars shall not be less than?

a)

2.0 db

b)

2.15 db

c)

1.50 db

d)

1.75 db

8.

In walls and slabs other than concrete joist construction, primary flexural reinforcement shall not be spaced farther apart than 3 times wall or slab thickness not farther than

a)

375 mm

b)

450 mm

c)

500 mm

d)

300 mm

9.

Groups of parallel reinforcing bars bundled in contact to act as one unit shall be united to _____ pieces in one bundle.

a)

4

b)

3

c)

2

d)

5

10.

Bars larger than _____ mm shall not be bundled in beams.

a)

25 mm

b)

16 mm

c)

28 mm

d)

36 mm

11.

Individual bars within a bundle terminated within the span of flexural members shall terminate at different points with at least _______

a)

12 db

b)

10 db

c)

50 db

d)

40 db

12.

Minimum concrete cover cast against and permanently exposed to earth

a)

100 mm

b)

75 mm

c)

50 mm

d)

150 mm

13.

The minimum clear concrete covering for cast in place slab

a)

20 mm

b)

25 mm

c)

40 mm

d)

50 mm

14.

In ultimate strength design, the strength reduction factor Ø for flexure without axial loads.

a)

0.85

b)

0.75

c)

0.90

d)

0.70

15.

In ultimate strength design, the strength reduction factor Ø for shear and torsion

a)

0.85

b)

0.75

c)

0.90

d)

0.70

16.

The minimum one way slab thickness which is simply supported at the ends only

a)

L / 20

b)

L / 24

c)

L / 28

d)

L / 10

17.

The minimum one way slab thickness for a one end continuous slab

a)

L / 20

b)

L / 24

c)

L / 28

d)

L / 10

18.

The minimum one way slab thickness for a both ends continuous slab

a)

L / 20

b)

L / 24

c)

L / 28

d)

L / 10

19.

The minimum cantilevered slab thickness

a)

L / 20

b)

L / 24

c)

L / 28

d)

L / 10

20.

Deep continuous flexural members has overall depth to clear span ratio greater than

a)

0.40

b)

0.60

c)

0.75

d)

0.70

21.

Deep simple span flexural members has overall depth to clear span ratio greater than

a)

0.40

b)

0.60

c)

0.75

d)

0.70

22.

Spacing of shear reinforcement placed perpendicular to axis of non-prestressed member shall not exceed

a)

d / 2

b)

d / 4

c)

3/4 d

d)

d / 5

23.

Development length for deformed bars in tension shall be less than

a)

300 mm

b)

250 mm

c)

200 mm

d)

350 mm

24.

An essentially vertical truss system of the concentric or eccentric type that is provided to resist lateral forces

a)

Building frame system

b)

Braced frame

c)

Diaphragm

d)

Collector

25.

A horizontal or nearly horizontal system activity to transmit lateral forces to the vertical resisting elements

a)

Building frame system

b)

Braced frame

c)

Diaphragm

d)

Collector

26.

A frame in which members and joints are capable of resisting forces primarily by flexture

a)

Moment resisting frame

b)

Ordinary braced frame

c)

Truss

d)

Eccentric braced frame

27.

In the determination of seismic dead load with a minimum of _______ of floor live load shall be applicable for storage and warehouse occupancies.

a)

50%

b)

25%

c)

30%

d)

35%

28.

The slope of cut surfaces shall be no steeper than ______ slope.

a)

50%

b)

60%

c)

30%

d)

40%

29.

Before commencing the excavation work, the person making the excavation shall notify in writing the owner of the adjoining building not less than _______ days before such excavation is to be made.

a)

15

b)

10

c)

30

d)

60

30.

Fill slopes shall not be constructed on natural slopes steeper than _____% slope.

a)

50

b)

10

c)

20

d)

60

31.

The minimum distance that the toe of fill slope made to the site boundary line

a)

0.80 m

b)

0.60 m

c)

1.50 m

d)

2.00 m

32.

The maximum distance that the toe of fill slope made to the site boundary

a)

0.80 m

b)

0.60 m

c)

6.00 m

d)

1.00 m

33.

In using sand backfill in the annular space around column not embedded in poured footings, the sand shall be thoroughly compacted by tamping in layers not more than ____ mm in depth

a)

500 mm

b)

400 mm

c)

200 mm

d)

300 mm

34.

In using a concrete backfill in the annular space around column not embedded in poured footings, the concrete shall have ultimate strength of __________ at 28 days.

a)

30 Mpa

b)

15 Mpa

c)

10 Mpa

d)

5 Mpa

35.

When grillage footings of structural steel shapes are used on soils, they shall be completely embedded in concrete. Concrete cover shall be at least _____ mm on the bottom.

a)

100 mm

b)

200 mm

c)

150 mm

36.

Temporary open air portable bleachers may be supported upon wood sills or steel plates placed directly upon the ground surface, provided soil pressure does not exceed ______.

a)

100 Kpa

b)

50 Kpa

c)

150 Kpa

d)

200 Kpa

37.

The minimum nominal diameter of steel bolts when wood plates or sill shall be bolted to foundation wall in zone 2 seismic area in the Philippines

a)

10 mm

b)

12 mm

c)

16 mm

d)

20 mm

38.

The minimum nominal diameter of steel bolts when wood plates or sill shall be bolted to foundation wall in zone 4 seismic area in the Philippines

a)

10 mm

b)

12 mm

c)

16 mm

d)

20 mm

39.

Individual pile caps and caissons of every structure subjected to seismic forces shall be interconnected by ties. Such ties shall be capable of resisting in tension or compression a minimum horizontal force equal to ____% of the largest column vertical load.

a)

15%

b)

20%

c)

10%

d)

25%

40.

Such piles into firm ground may be considered fixed and laterally supported at _____ meters below the ground surface.

a)

1.50 meters

b)

2.00 meters

c)

2.50 meters

d)

3.00 meters

41.

Such piles into soft ground may be considered fixed and laterally supported at _____ meters below the ground surface.

a)

1.50 meters

b)

2.00 meters

c)

2.50 meters

d)

3.00 meters

42.

The maximum length of cast in place piles/bored piles shall be _____ times the average diameter of the pile

a)

10

b)

20

c)

30

d)

15

43.

Cast in place/bored piles shall have a specific compressive strength of not less than _________.

a)

17.50 Mpa

b)

20 Mpa

c)

15 Mpa

d)

25 Mpa

44.

Pre-cast concrete piles shall have a specific compressive strength of not less than _________.

a)

17.50 Mpa

b)

20 Mpa

c)

15 Mpa

d)

25 Mpa

45.

The maximum spacing of ties and spirals in a driven pre-cast concrete pile center to center

a)

75 mm

b)

100 mm

c)

125 mm

d)

150 mm

46.

Pre-cast pre-stressed concrete piles shall have a specified compressive strength of not less than ________.

a)

20 Mpa

b)

15 Mpa

c)

25 Mpa

d)

35 Mpa

47.

The minimum outside diameter of pipe piles when used must be

a)

300 mm

b)

250 mm

c)

350 mm

d)

400 mm

48.

Occupancy of aviation control towers

a)

Special occupancy structures

b)

Essential facilities

c)

Hazardous facilities

d)

Standard occupancy

49.

Occupancy type of private garages, carports, sheds, agricultural buildings

a)

Miscellaneous occupancy

b)

Essential facilities

c)

Special occupancy

d)

Hazardous facility

50.

Buildings used for college or adult education with a capacity of 500 or more students fall to what type of occupancy?

a)

Miscellaneous occupancy

b)

Essential facilities

c)

Special occupancy

d)

Hazardous facility