NEW
Font size
WorksheetsMotor Control- 8 Reversing Motor Controls
Total questions: 25
Worksheet time: 13mins
NEMA and IEC recommend reversing motor connections T1 and _________________ to reverse the direction of rotation for a three-phase motor.
T2
T3
L2
L3
Two common methods used to reverse a three-phase motor are reversing magnetic motor starter and _________________ switches.
Limit
Pressure
Drum
Pushbutton
A drum switch provides a(n) __________________ method to change the direction of rotation for a motor.
Automatic
Switching
Stopping
Manual
A drum switch contains moveable contacts on an insulated ____________________.
Actuator
Rod
Shaft
Switch
Drum switches do not have _________________ protection to protect the motor.
Overload
Circuit
Overdraft
Voltage
A reversing magnetic motor starter has ________________ relay Coils.
Two
Three
One
Four
Each relay in a reversing magnetic motor starter has its own set of _____________________________.
Controls
Contacts
Motors
Limit Switches
When connecting to the reverse side of a magnetic motor starter, L1 is connected to ______________________
L3
L2
T2
T3
When connecting to the forward side of a magnetic motor starter, L2 is connected to _________________.
L3
L1
T1
T2
When connecting to the reverse side of a magnetic motor starter, L3 is connected to _____________
T1
T2
T3
L1
To avoid ____________________ both coils of a reversing magnetic motor starter at the same time, interlocks are used.
Disabling
Energizing
Stopping
Starting
The __________________ method of interlocking is the most common method. It uses the normally closed auxiliary contacts of the reversing magnetic motor starter.
T1 to L3
ON/OFF
Auxiliary Contact
Mechanical
The __________________ method of interlocking uses two double-pole Single-throw (DPST) pushbuttons to create the interlock.
Control Relay
Limit Switch
Drum Switch
Pushbutton
The _____________________ method of interlock uses a lever to physically prevent the armature of one of the coils from moving.
Pushbutton
Auxiliary Contact
Mechanical
Physical
Electrical interlocking is often used with mechanical interlocking to protect the coils from damage
True
False
In the manual mode of machine operation, operators often _____________ an actuator to position it.
Run
Reverse
Jog
Start
The manual mode is most often used during machine set-up and _____________________.
Normal operation
Maintenance
Troubleshooting
Skeet Shooting
A(n) ___________________ circuit uses a locking pushbutton to switch between manual and automatic modes.
Pushbutton
Auxiliary
Selector Switch
Lock-Step
A(n) __________________ switch is often used to select modes of operation.
Pushbutton
Limit
Pressure
Selector
The _________________ mode repeatedly cycles a machine.
Manual
Rinse Cycle
Automatic
Remote
The motor automatically runs continuously in the ______________________ mode.
Automatic
HAND
ON/ON
ON/RUN
A(n) ___________________ circuit provides a continually operating motor mode, Off mode, and automatic mode,
Jog-Off-Run
HAND
Hand-Off-Automatic
ON/ON
A(n) ___________________ circuit provides a jog mode, off mode, and automatic mode.
Hand-Off-Automatic
ON/ON
ON/OFF
Jog-Off-Run
A common application for the H-O-A circuit is a(n) __________________ system for crops.
Harvesting
Fertilizing
Planting
Irrigation
When the automatic mode is selected in a H-O-A circuit, the motor will not run until certain conditions are met.
True