Font size
WorksheetsBasic Electrical Engineering-Internals
Total questions: 26
Worksheet time: 20mins
KVL and KCL deals with the conservation of
Mass
Momentum
Charge
Energy
The sum of all the voltages over any closed loop is equal to
1V
0V
infinity
Supply voltage
What is the basic law used to analyze any circuit
Kirchhoff's laws
Amperes's law
Faraday's law
Newton's law
In superposition theorem, when we consider the effect of one voltage source, all the other voltage sources are:
Undisturbed
Shorted
Opened
Altered
Thevenin's voltage is the:
Open circuited voltage
Short circuited voltage
Voltage across the load
None of the above
Norton's current is the:
Short circuit current
Open circuit current
None of the above
Current through the load resistor
Maximum power is transferred from the source to the load when:
Source and load impedances match
Source and load elements are passive
Source admittance matches with load impedance
Source and load admittances match
Short circuit test in transformers are used to identify
Copper losses
Winding losses
Current losses
Voltage losses
What happens to the current in a series circuit if the resistance is doubled?
Current doubles
Current is reduced to half of its original value
No change
KWh is unit of
Power
Energy
Variance
Efficiency
An autotransformer has only one winding on its core.
TRUE
FALSE
The power dissipated as heat in the primary and secondary windings of a transformer due to its winding resistance is called copper loss because:
This loss occurs in the copper windings of the transformer
Copper is also lost in the windings because of heat
Losses in the transformer due to alternating flux in the core is called:
Core loss
Copper loss
Short Circuit Loss
Core loss in transformers are also called:
Copper Loss
Iron Loss
Hysteresis loss is caused due to magnetization and demagnetization in the transformer core.
True
False
Iron loss comprises of:
(choose all that apply)
Hysteresis Loss
Eddy Current Loss
Copper Loss
Power Loss
kVA represents the apparent power of an electrical system.
True
False
Actual power, kW is defined as:
kVA X Power Factor
Power FactorkVA
kVAPower Factor
For DC Circuits kVA and kW are equal because
Power Factor for DC circuits is unity
Power Factor for DC circuits is less than 1
Power Factor for DC circuits is greater than 1
Power factor is the measure of how effectively the incoming power is used in the electrical system.
True
False
__________ is defined as the cosine of the angle between voltage and current
Power Factor
Power
Variance
Impedance
Which among the following are inductive loads:
(choose all that apply)
Incandescent Lamps
Power Generators
Motors
Buried cables
Speakers
The theorem used for analyzing electric circuits that contains two or more active sources is:
Super position Theorem
Reciprocity theorem
Thevenin's theorem
Norton's theorem
Capacitive loads have leading power factor because
Current leads voltage
Voltage leads Current
Voltage and Current increases proportionally
Voltage and Current decreases proportionally
For an incandescent lamp the power factor is:
Unity
Greater than 1
Less than 1
Cannot be pre determined
Inductive loads have:
Leading power factor
Lagging power factor
Unity power factor
