ICIT: Revision (Fire Alarm)

Total questions: 30

Worksheet time: 15mins

Name
Class
Date
1.

A fire alarm system is required in a building for

a)

protection of life.

b)

protection of earth fault.

c)

protection of short-circuit.

d)

protection of overload.

2.

The purpose of a fire alarm is to provide an immediate alarm and so

a)

prevent loss of life

b)

prevent spared of fire.

c)

eanble the staff to isolate the zone.

d)

enable staff to rectify the fault.

3.

The colour for all fire alarm panels, bells, conduit, trunking and manual call points shall be

a)

RED

b)

BLUE

c)

GREEN

d)

YELLOW

4.

The purpose of a fire alarm is to Secure the immediate attention of fire fighting staff / authority

a)

True

b)

False

5.

The type of system is determined by the type of remoteactuating device employed, namely:

a)

close-circuit system and open-circuit system.

b)

Series circuit system and paralle circuit sytem.

c)

star-connected system and delta connected system.

d)

ring circuit system and radia circuit system.

6.

If an alarm condition is identified then the main alram panel

a)

activates the sounders

b)

turn-on all lighting.

c)

trip the main supply intake

d)

turn-off all lighting.

7.

The fire alarm panel must always be situated in a position where the FireBrigade can easily see and find it.

a)

True

b)

False

8.

The color used for fire alarm indication is

a)

red

b)

blue

c)

green

d)

yellow

9.

The color for system fault indication in fire alarm system is

a)

red

b)

blue

c)

yellow

d)

green

10.

The color used for System energization indication in fire alarm system is

a)

red

b)

blue

c)

green

d)

yellow

11.

The color used for Isolate indicator in fire alarm system must be any colour other than

a)

red

b)

green

c)

blue and yellow

d)

red and green.

12.

The Isolation facility in the fire alarm system is to

a)

isolate alarm zone.

b)

test the fire alarm system.

c)

activate the sounder.

d)

reset the alram system

13.

Isolation facility can only access by building management appointedauthorised personnel.

a)

True

b)

False

14.

The indicating lamps of a fire alram panel used two filament lamps connected in

a)

delta.

b)

star.

c)

series.

d)

parallel.

15.

The fire alarm panel of the fire alarm system monitors the detection wiring and devices for faults and operation.

a)

True

b)

False

16.

The connections of fire service signalling transmitter completely enclosedand not accessible to unauthorised persons

a)

True

b)

False

17.

A separate alarm zone shall be provided of protected floor area for every

a)

1000m2

b)

2000m2

c)

3000m2

d)

4000m2

18.

A separate alarm zone is required for each fire compartment and each

a)

room.

b)

floor.

c)

school.

d)

department.

19.

The detectors used in a fire alarm system are automatic detectors and used to constantly monitor the surroundings.

a)

True.

b)

False.

20.

identify the part used in the fire alarm system.

a)

Exit point.

b)

Flame Detector.

c)

Smoke Detector.

d)

Manual Call Point.

21.

The capacity of the battery in the fire alarm system shall be able to maintain the system for at least

a)

1 hour.

b)

6 hour.

c)

12 hour.

d)

24 hour.

22.

The battery capacity must able to supplying the full emergency evacuation alarm load for a period of at least

a)

5 minutes.

b)

10 minutes.

c)

30 minutes.

d)

60 minutes.

23.

PVC insulated cable shall not be used in where the ambienttemperature likely to exceed

a)

45ºC.

b)

65ºC.

c)

75ºC.

d)

95ºC.

24.

Rigid PVC conduit system may be used situations in less than

a)

50ºC .

b)

60ºC .

c)

70ºC .

d)

90ºC .

25.

The Code of Practice for Installation and Servicing of Electrical Fire Alarm Systems is

a)

SS 638:2018

b)

SS 641:2019

c)

SS 645 : 2019

d)

SS 650 - 1 : 2019

26.

Identify the symbol used in fire alarm system.

a)

flame detector.

b)

heat detector.

c)

smoke detector.

d)

manual call point.

27.

identify the symbol used in fire alarm system

a)

auto detector.

b)

heat detector.

c)

smoke detector.

d)

manual call point.

28.

PVC insulated cable for fire alarm system shall be laid in

a)

PVC conduit

b)

PVC trunking

c)

metal conduit

d)

metal cable tray

29.

Identify the fire alarm system component shown below.

a)

Beam Sensor

b)

heat detactor

c)

Smoke Detector

d)

Manual Call Point

30.

The colour for fault indicator designated "Fault" is

a)

blue

b)

green

c)

red

d)

yellow