Electrical installation 203 2

Total questions: 20

Worksheet time: 10mins

Name
Class
Date
1.

Which flexible cable would you use for connecting a boiler or electric heater?

a)

90 degree heat resistant thermoplastic PVC

b)

SWA

c)

185 degree glass fibre insulated braided cable

d)

Mineral Insulated cable

2.

Which type of cable would be the best for mechanical protection outdoors

a)

Mineral Insulated

b)

FP 200

c)

HOFR flex

d)

SWA

3.

What colour is a 30 A 3036 fuse?

a)

Blue

b)

White

c)

Red

d)

Green

4.

What is the main use of an RCD in a standard domestic installation?

a)

Additional protection

b)

Automatic disconnection of supply

c)

Class 2 fittings

d)

Supplementary bonding

5.

Where would you most likely use metal trunking?

a)

For data cables in a commercial setting

b)

Industrial installation with singles wiring

c)

Embedded in a wall behind plasterboard

d)

Instead of skirting board in a house

6.

What will affect PVC conduit factor apart from length?

a)

Number of bends in conduit

b)

Type of conduit

c)

The colour of the conduit

d)

the amount of saddles used

7.

When do you need a ferrule on FP200 cable?

a)

Always

b)

If used in wet areas

c)

If it has a silicone inner sheath

d)

Only on red FP200

8.

What does LSF stand for as in cable type?

a)

Lots of small filings

b)

light sheath fire

c)

Low smoke and fume

d)

lots of stranded fibres

9.

What is the disconnection time for a circuit with a 6A MCB?

a)

0.4 seconds

b)

7 seconds

c)

5 seconds

d)

6 seconds

10.

What type of support is the best for lots of small cables?

a)

Basket tray

b)

Conduit

c)

Trunking

d)

Clipped direct

11.

What type of fuse is a BS 3036?

a)

Plug top

b)

cartridge fuse

c)

GM fuse

d)

rewireable fuse

12.

What type of fuse is a BS 1362?

a)

Rewireable fuse

b)

plug top fuse

c)

GM fuse

d)

Cartridge fuse

13.

What rating needs to be equal or higher than the In rating?

a)

Rated current of the protective device

b)

Current carrying capacity due to installation conditions

c)

Design current

d)

Fuse/ MCB breaking capacity

14.

Which one of the following do you not need to consider for cable correction factors?

a)

Ambient temperature

b)

If the cable is buried

c)

If there are more than one cable ran together

d)

How many bends are in the cable

15.

What is the maximum volt drop allowed for power circuits?

a)

10%

b)

3%

c)

5%

d)

8%

16.

What is the maximum volt drop allowed for lighting circuits?

a)

5%

b)

10%

c)

3%

d)

8%

17.

What causes an RCD to operate?

a)

Heat

b)

Magnetism

c)

humidity

d)

time

18.

What must be connected to main bonding conductors?

a)

Incoming metal water and gas pipes

b)

Incoming plastic water and gas pipes

c)

metal heating system pipes

d)

metal taps and sinks

19.

On a TNS earthing system is the earth.....

a)

Separate to the supply neutral coming in

b)

Combined with the neutral cable coming into the property

c)

provided by the customer

d)

Not available

20.

What is a BSEN 60898?

a)

RCBO

b)

RCD

c)

MCB

d)

Rewireable fuse