Total questions: 22
Worksheet time: 11mins
What is the main purpose of a central heating system?
To heat up the core of the building
To provide thermal comfort to a property
To supply heating to a single room
To provide heat to a number of properties
1. What type of heating system incorporates a three-port valve that gives priority to the hot water system?
Y plan
S plan
S plan+
W plan
What is this component?
Blank cap
Bleed valve
Automatic air vent
Expansion vessel
Name this component
BS 1212 part 1 FOV
BS 1212 part 2 FOV
BS 1212 part 3 FOV
BS 1212 part 4 FOV
Name this component
Room thermostat
Programmer
Cylinder thermostat
Remote sensor
Identify this component
Pressure relief valve
Radiator valve
Lockshield valve
Automatic air vent
Which system of control would this item be used with?
C plan
C plan +
S paln
Y plan
This is an underfloor heating manifold
True
False
The purpose of fitting a bypass valve is to
Allow water to circulate through the radiators after the motorized valve has closed.
Allow water to circulate between the flow and return from the boiler after the motorized valve has closed.
Allow water to circulate through the cylinder after the motorized valve has closed.
Allow water to circulate through the boiler to balance the system.
The type of system a Honeywell 'S' plan is....
3 port mid position valve
3 port diverter valve
2 x 2 port zone valves
3 x 2 port zone valves
The purpose of this is to ....
Allow for the expansion of the system pipework
Allow for the expansion of the water in the system
Allow for the expansion of steam in the system
Allow for the expansion of the air in the system
What type of system can generate Heat and power
Combination Boiler
Combined Heat and power system
A Biomass heating system
Heat only boiler
How would you join more that one boiler together
Two Pumps
High Loss Header
Low Loss header
4" copper pipe
This picture shows a?
Circulator
Two port valve
Three port valve
Programmer
Under floor heating works at approximately what temperature?
60
43
35
21
The types of system used in commercial and industrial buildings include?
two-pipe parallel return, two-pipe reverse return and pumped primary and secondary
two-pipe parallel return, two-pipe reverse return and Gravity primary and secondary
two-pipe parallel return, One-pipe reverse return and pumped primary and secondary
One-pipe parallel return, two-pipe reverse return and pumped primary and secondary
In what type of system is there no requirement for balancing because the system ‘self balances?
Two-pipe reverse return systems
Two-pipe parallel return systems
Pumped primary/pumped secondary systems
Combi system
Multiple boiler installations often incorporate a?
Second pump
Low loss header
High gain header
Turbo speed pump inducer
Which system is designed to control the temperature passing through the heat emitters to compensate for external environmental conditions?
Two pipe reverser returned
Constant volume/variable temperature compensated heating circuit
Multiple boiler plantroom with low loss header
Compensated heating control
This picture shows a?
In-line twin centrifugal pump set
In-line triple centrifugal pump set
In-line twin shower pump set
Double regulating valve with binder test points
This picture shows a?
In-line twin centrifugal pump set
In-line triple centrifugal pump set
In-line twin shower pump set
Double regulating valve with binder test points
This image shows a?
Radiant heat emitters
Above floor heating
Panel radiator
Fan convector