wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Electrician 3rd Sem Module 5 Alternator

Total questions: 25

Worksheet time: 13mins

Name
Class
Date
1.
Which formula is used to calculate EMF/phase in a ideal alternator?
a)

E=ϕFT2.22E=\frac{\phi FT}{2.22}  

b)

E=ϕFT4.44E=\frac{\phi FT}{4.44}  

c)

E=2.22ϕFTE=2.22\phi FT  

d)

E=4.44ϕFTE=4.44\phi FT  

2.
Which rule is used to find the direction of induced emf in an alternator?
a)
Cork screw rule
b)
Right hand palm rule
c)
Fleming’s left hand rule
d)
Fleming’s right hand rule
3.
What is the name of the part of alternator?<br />
a)
Stator
b)
Exciter
c)
Salient pole rotor
d)
Smooth cylindrical rotor
4.
What is the formula to calculate emf equation of an alternator?
a)

E=4.44KdKcTɸmE=4.44K_dK_cTɸm  

b)

E=2.22KdKcFɸmE=2.22K_dK_cFɸm  

c)

E=4.44KdKcFTɸmE=4.44K_dK_cFTɸm  

d)

E=1.11KdKcFɸmE=1.11K_dK_cFɸm  

5.
How alternators are rated?
a)
KVA
b)
KW
c)
MW
d)
KV
6.
Which formula is used to calculate the<br />percentage voltage regulation in alternator?
a)

VFLVNLVFL×100\frac{V_{FL}-V_{NL}}{V_{FL}}\times100  

b)

VNLVFLVFL×100\frac{V_{NL}-V_{FL}}{V_{FL}}\times100  

c)

VNLVFLVNL×100\frac{V_{NL}-V_{FL}}{V_{NL}}\times100  

d)

VFLVNLVNL×100\frac{V_{FL}-V_{NL}}{V_{NL}}\times100  

7.
What is the supply frequency of an alternator having 6 poles runs at 1000 rpm?
a)
25 Hz
b)
40 Hz
c)
50 Hz
d)
60 Hz
8.
Calculate the speed of an alternator having 2 poles at a frequency of 50 Hz?
a)
1500 rpm
b)
2500 rpm
c)
3000 rpm
d)
6000 rpm
9.
What condition the lamps become dark in dark lamp method of parallel operation of two alternators?
a)
Terminal voltages are equal
b)
Voltage and frequency are equal
c)
Voltage and power rating are equal
d)
Frequency are same in both alternator
10.
How to compensate de-magnetizing effect due to armature reaction in an alternator?
a)
Reducing the speed of alternator
b)
Reducing field excitation current
c)
Increasing field excitation current
d)
Increasing the speed of alternator
11.
What is the use of synchroscope?
a)
Adjust the output voltage
b)
Adjust the phase sequence
c)
Adjust the supply frequency
d)
Indicate the correct instant for paralleling
12.
What is the name of the equipment that provides D.C to the rotor of alternator?
a)
Exciter
b)
Inverter
c)
Converter
d)
Synchroniser
13.
What is the purpose of damper winding in alternator?
a)
Reduces the copper loss
b)
Reduces windage losses
c)
Reduces the hunting effect
d)
Improves the voltage regulation
14.
Which condition is to be satisfied before parallel operation of alternators?
a)
Rating must be same
b)
Phase sequence must be same
c)
Rotor impedance must be same
d)
Stator impedance must be same
15.
What is the speed of an alternator connected with a supply frequency of 50 Hz at rated voltage having 4 poles?
a)
1000 rpm
b)
1500 rpm
c)
3000 rpm
d)
4500 rpm
16.
What condition the two lamps become bright and one lamp dark during paralleling of two alternators?
a)
Terminal voltages are equal
b)
Voltages and frequencies are equal
c)
Voltages and phase sequence are equal
d)
Both the alternators receive same frequency
17.
What causes the terminal voltage of an alternator reduces, if the load increases?
a)
Field resistance
b)
Armature reaction
c)
Inductive reactance
d)
Armature resistance
18.
What is the purpose of using damper winding in AC generator?
a)
Prevents heating
b)
Reduces copper loss
c)
Reduces windage loss
d)
Prevents the hunting effect
19.
What is the type of alternator?
a)
Brushless alternator
b)
Three phase alternator
c)
Single phase alternator
d)
Salient pole type alternator
20.
Calculate the speed in r.p.s of the 2 pole, 50Hz alternator?
a)
50 rps
b)
100 rps
c)
1500 rps
d)
3000 rps
21.
What is the advantage of using rotating field type alternator?
a)
Easy to locate the faults in the field
b)
Easy to connect the load with alternator
c)
Easy to dissipate the heat during running
d)
Two slip rings only required irrespective of No. of phases
22.
What is the effect in increasing the field excitation current in alternator?
a)
Prevents demagnetizing
b)
Over voltage protection
c)
Dead short circuit protection
d)
Alternator will be over loaded
23.
Calculate the pitch factor (KP) for a winding having 36 stator slots 4 pole with angle (α) is 30° in alternator?
a)
0.942
b)
0.965
c)
0.978
d)
0.985
24.
What is the cause for hunting effect in alternators?
a)
Due to over load
b)
Running without load
c)
Running with fluctuation of speed
d)
Due to continuous fluctuation in load
25.
Calculate the voltage regulation in percentage if the load is removed from an alternator, the voltage rises from 480V to 660V?
a)

27.2%

b)

32.5%

c)

37.5%

d)

38.5%