1.

To ensure compliance of the provisions of this Code, the professional services of a Registered and Licensed Master Plumber shall be enlisted in accordance with Republic Act No. 1378, the "_____".

a)

Plumbing Law

b)

Plumbing Code

2.

No permit shall be issued to any person, firm or corporation, to do or cause to be done any installation of plumbing work regulated by this Code, except to a Registered and Licensed Master Plumber, holding a valid, ______ as required by Republic Act No. 1378, as amended .

a)

unexpired and unrevoked certificate of registration

b)

Updated Cedula

3.

All plumbing plans, drawings. diagrams, design analyses/computations as required, technical specifications, bills of materials and other required documents for all types of occupancy shall be prepared, signed and sealed by a________and shall be submitted in six (6) sets of the aforementioned requirements with each application for a permit.

a)

Registered and Licensed Architect.

b)

Registered and Licensed Master Plumber. without limitations. pursuant to Republi~ Act 1378, as amended.

4.

_____ shall file an application at the Office of the Building Official in behalf of the building Owner for whom such work shall be done and shall till out the forms provided for that purpose.

a)

A Registered and Licensed Master Plumber

b)

Owner

5.

The______submitted shall comply with the provisions of existing standards of the National Building Code and this Code.

a)

technical specifications

b)

plumbing plan

6.

When the Administrative Authority issues the permit he shall endorse in writing or stamp the plans and specifications as "_____". Such approved plans and specifications shaH not be changed, modified or altered without authorization from the Administrative Authority and aU works shall be done in accordance with approved plans and specifications.

a)

APPROVED

b)

VALID

7.

The Administrative Authority may issue a ______ for the construction of a part of a large and/or complicated plumbing system before the entire plans and specifications for the whole system have been submitted or approved, provided adequate information and detailed statements have been filed, complying with all pertinent requirements of this Code.

a)

Partial Permit

b)

Temporary Permit

8.

The holder of such partial permit may proceed at his own risk _____ that the final permit for the entire building, structure or plumbing system will be granted.

a)

without assurance

b)

guaranteed

9.

Retention of Plans- One set of approved plans, specifications, computations and related data shall be retained by the Administrative Authority. _____sets of approved plans, specifications and data shall be returned to the applicant and Owner, one ( 1) set of which shall be kept at the jobsite at all times while the work is in progress.

a)

Two (2)

for owner

b)

one (1)

for owner

10.

A plumbing permit issued under the provisions of this Code shall expire and become null and void if the plumbing work authorized therein is not commenced within _____ from the date of such permit or if the plumbing work so authorized is suspended or abandoned at any time after having been commenced for a period of 120 days.

a)

one year

b)

120 days

11.

the plumbing work so authorized is suspended or abandoned at any time after having been commenced for a period of _____ days.

a)

120

b)

90

12.

administrative Personnel, Plumbing lnspector shall be a Registered and Licensed Master Plumber in accordance with the provision of Republic Act 378, otherwise, known as "___··.

a)

Plumbing Law

b)

Building Code

13.

The application, plans technical specifications and other required documents filed by an applicant for a permit shall be reviewed by the ___

a)

Administrative Authority

b)

Registered Master Plumber

14.

In case of renewal of a plumbing permit, a fee equivalent to ____ the amount of the original fee shall be paid.

a)

one-half

b)

one-third

15.

The Administrative Authority may, in writting, _____ a permit issued under the provisions of this Code whenever issued in error or on the basis of incorrect information supplied or in violation of pertinent ordinances, rules and regulations.

a)

suspend or revoke

b)

total demolition

16.

The ___ or his designated agent shall be responsible for the maintenance of plumbing systems.

a)

owner

b)

plumber

17.

Plumbing systems, which are part of buildings or structures in one place and moved into another Jurisdiction. shall comply with the provisions of this Code for _____.

a)

new installation

b)

asbuilt

18.

The ______ or his representative shalt not be liable for expenses incurred in the removal and replacement of materials required to warrant proper inspection.

a)

Administrative Authority

b)

Master Plumber

c)

Owner

19.

When the installation of a plumbing system is complete, ____ shall be made.

a)

additional and final inspection

b)

occupancy permit

20.

All plumbing systems shall be ____ as required by this Code or the Administrative Authority.

a)

tested and approved

b)

Checked and Approved

c)

Well operated

21.

no person shall install connections to any water supply line, sewer or storm drain systems as required by this Code and for which other applications and permits are also required from other Agencies before approval by the ____.

a)

Administrative Authority

b)

Owner

22.

________shall be a Registered and Licensed Master Plumber in accordance with the provision of Republic Act 1378, otherwise, known as "Plumbing Law··.

a)

all administrative Plumbing Personnel, plumbing Inspector

b)

Not all all administrative Plumbing Personnel, plumbing Inspector

23.

Administrative Authority not more than _____hours after such replacement work is completed and before any portion of such plumbing system is concealed by any permanent portion of the building.

a)

72 hours

b)

120 hours

24.

The ______or his representative shalt not be liable for expenses incurred in the removal and replacement of materials required to warrant proper inspection.

a)

Administrative Authority

b)

owner

25.

All _____ in accordance with the provisions of Republic Act No. 1378 shall secure for themselves a seal of the standard size and type as required.

a)

Licensed Master Plumbers registered

b)

Plumbers

26.

It shall be unlawful for any person, firm or corporation, whether acting as

principal, setvant, agent or employee, to do or cause to be done any plumbing or

drainage work for which a permit is required without securing prior permit from

the Office of lhe Building Official having jurisdiction _____

a)

under the Department of

Public Works and Highways, Department of Interior & Local Government or

City Mayors.

b)

under barangay councel and city mayor

27.

The technical specifications submitted shall comply with the provisions of

existing standards of the ____

a)

Plumbing Code and this Code.

b)

National Building Code and this Code.

28.

-One set of approved plans, specifications, computations and

related data shall be retained by the Administrative Authority.

-Two (2) sets of

approved plans, specifications and data shall be returned to the applicant a!ld

Owner,

- one ( 1) set of which shall be kept at the jobsite at all times while the work

is in progress.

a)

Retention of Plans

b)

Validity of Permit

29.

The ____ or his designated agent shall be responsible for the

maintenance of plumbing systems.

a)

master plumber

b)

owner

30.

all administrative plumbing Personnel, plumbing inspector shall be a Registered

and Licensed Master Plumber in accordance with the provision of

______, otherwise, known as "Plumbing Law"

a)

Republic Act 1378

b)

Republic Act 1398

31.

1. Registered and Licensed Master Plumber at upper portion of the round

seal.

2. Name of Registered and Licensed Master Plumber at the upper center.

3. The registration number shall appear at the center below the name.

4. Philippines, appearing at the lower portion of the round seat

a)

The seal

shall be round in shape and shall be inscribed

b)

The seal

shall be square in shape and shall be inscribed

32.

The issuance of a permit based on submitted plans. specifications or other documents shall not prevent the ______ from thereafter requiring the correction of errors on said plans, specifications and other documents . and from stopping an on-going plumbing installations violative of this Code or of other pertinent ordinances of this Jurisdiction.

a)

Administrative Authority

b)

Master Plumber

33.

The Administrative Authority may, in writing _____ a permit issued under the provisions of this Code whenever issued in error or on the basis of incorrect information supplied or in violation of pertinent ordinances, rules and regulations.

a)

suspend or revoke

b)

Warning letter

34.

may be made to any existing plumbing system provided the addition, alteration or repair works conform to requirements for a new plumbing system

a)

Additions, Alterations or Repain

b)

Changes in Building Occupancy

35.

shall not render an existing system unsafe, unsanitary or overloaded.

a)

Additions, alterations or repairs

b)

Changes in Building Occupancy

36.

Plumbing systems which are a part of any building or structure undergoing a change in use or occupancy, as defined in the National Building Code, shall comply with all requirements of this Code

a)

Changes in Building Occupancy

b)

Additions, Alterations or Repain

37.

No portion of any plumbing system shall be concealed until _____

a)

inspected and approved.

b)

permit released

38.

Plumbing systems regulated by this Code shall not be connected to the ______ supplies nor to the sewer system until authorized by the Administrative Authority and other Agencies concerned.

a)

water and energy fuel

b)

water and sanitary

39.

The Administrative Authority requires that every request for inspection be filed atleast _____ before such inspection is intended.

Such request shall be in writing and jointly signed by the Owner and the Registered and Licensed Master Plumber- Contractor.

a)

three (3) working days

b)

five (five) working days

40.

Each building shall be provided with sanitary facilities in accordance with best practice for ______ as provided in the National Building Code of the Philippines or by other government departments having jurisdiction

a)

mobility of disabled persons

b)

mobility of every persons

41.

_____shall be charged when the approved plans are not readily available to the Inspector, for failure to provide access and facility on the date when the inspection is requested, or for deviating from plans requiring the approval of the Administrative Authority.

a)

Re-inspection fees

b)

Re-application fees