MEDICAL EQUIPMENT FINAL EXAM

EEG (Electroencephalograph) is related to the activities of _______.

a)

Nerve fiber

b)

Muscle

c)

Brain

d)

skin

2.

What biological measurement is done by the Spirometer?

a)

Blood pressure measurement

b)

Blood Flow measurement

c)

Respiratory volume measurements

d)

Blood sugar measurement

3.

Which of the following statements is true about Needle electrodes?

a)

They are designed to measure bioelectric potentials near or within the cell.

b)

They are designed to penetrate the skin so that they can record biopotentials like EEG signals from the brain.

c)

They are designed to measure biopotentials from the surface of the skin.

d)

Typical examples include the metal microelectrodes and micropipette.

4.

Choose the correct option

a)

sharps containers

b)

latex

c)

waste

d)

oxygen tank

5.

Who can install, maintain and repair medical equipment and medical devices?

a)

speech therapist 

b)

dental hygienist

c)

medical technician

d)

specialist

6.

Defibrillator

a)
b)
c)
d)
7.

Sphygmomanometer

a)
b)
c)
d)
8.

What is the name of this device

a)

Pulse oximeter / SpO2 monitor 

b)

X-ray machine

c)

Thermometer

d)

Blood Glucose Monitor

9.

What is the name of this device

a)

Pulse oximeter / SpO2 monitor 

b)

X-ray machine

c)

Thermometer

d)

Blood Glucose Monitor

10.

What is the name of this device

a)

Pulse oximeter / SpO2 monitor 

b)

X-ray machine

c)

Thermometer

d)

Blood Glucose Monitor

11.

What is the name of this device

a)

Pulse oximeter / SpO2 monitor 

b)

X-ray machine

c)

Thermometer

d)

Blood Glucose Monitor

12.

Capture the images of bones 

a)

Pulse oximeter / SpO2 monitor 

b)

X-ray machine

c)

Thermometer

d)

Blood Glucose Monitor

13.

Measures blood oxygen

a)

Pulse oximeter / SpO2 monitor 

b)

X-ray machine

c)

Thermometer

d)

Blood Glucose Monitor

14.

Device that measures body temperature

a)

Pulse oximeter / SpO2 monitor 

b)

X-ray machine

c)

Thermometer

d)

Blood Glucose Monitor

15.

Measures blood sugar

a)

Pulse oximeter / SpO2 monitor 

b)

X-ray machine

c)

Thermometer

d)

Blood Glucose Monitor

16.

What does troubleshooting mean?

a)

It is the process of solving an issue to repair failed products

b)

It is a fight between two different equipments

c)

It means..trouble ปัญหา, shoooting การยิง

17.

To troubleshoot an equipment the technician should...

a)

fully understand the manufacturer work as well as the possible designs

b)

fully understand the hospital as well as the personnel.

c)

fully understand the equipment work as well as the possible failures

d)

fully understand the personnel work as well as the salary they earn.

18.

What is the first step to troubleshoot a Pulse Oximeter.

Problem: No power from mains socket/ (Battery (if present) is discharged Electrical cable fault

a)

Recharge or replace battery

b)

Check power switch is on

c)

Replace fuse

d)

Try cable on another piece of equipment

19.

What is the second step to troubleshoot a Pulse Oximeter.

Problem: No power from mains socket/ (Battery (if present) is discharged Electrical cable fault

a)

Check mains power is present at socket using equipment known to be working

b)

Recharge or replace battery

c)

Replace fuse

d)

Check power switch is on

20.

What is the third step to troubleshoot a Pulse Oximeter.

Problem: No power from mains socket/ (Battery (if present) is discharged Electrical cable fault

a)

Recharge or replace battery

b)

Check power switch is on

c)

Try cable on another piece of equipment

d)

Check mains power is present at socket using equipment known to be working

21.

What is the fourth step to troubleshoot a Pulse Oximeter.

Problem: No power from mains socket/ (Battery (if present) is discharged Electrical cable fault

a)

Recharge or replace battery

b)

Replace fuse

c)

Check power switch is on

d)

Try cable on another piece of equipment

22.

What is the last step to troubleshoot a Pulse Oximeter.

Problem: No power from mains socket/ (Battery (if present) is discharged Electrical cable fault

a)

Check mains power is present at socket using equipment known to be working

b)

Replace fuse

c)

Recharge or replace battery

d)

Try cable on another piece of equipment

23.

Scheduled maintenance to ensure the performance and reliability of all biomedical equipment are at optimum level as standard set by the manufacturer.

a)

Parts per million

b)

Productive preventive maintenance

c)

Pre-planned preventive maintenance

d)

Plan preventive maintenance (PPM)

24.

Work request by the user when defect or failure in the operation are detected.                              

a)

Service Maintenance

b)

Breakdown Maintenance

c)

Engineer Maintenance

d)

Machinaire Maintenance

25.

Action following a breakdown which is indented to make the medical equipment work for a long time (as opposed to just fixing it and only providing a temporary solution)

a)

Quality Control

b)

Corrective Maintenance

c)

Monitoring Technology

d)

Security Alarm

26.

We have ____________ form at break-down of machines                                                   

a)

Maintenance form

b)

Bio-medical service request form

c)

Break reporting form

d)

Emergency form

27.

On call situation where engineer or technician responsible come and solve problem.                                             

a)

Emergency Maintenance

b)

Bio-medical service Maintenance

c)

Break reporting

d)

Emergency form

28.

What does a medical alarm means?       

a)

Alarm in medical

b)

Required urgent attention

c)

Negligence

d)

Security Alarm

29.

What does a medical alarm means?       

a)

Alarm in medical

b)

Required urgent attention

c)

Negligence

d)

Security Alarm

30.

Document containing PPM procedure and safety analyzer report. 

a)

Support Services

b)

Acceptance testing

c)

Service report

31.

Into what pathway does a biomedical equipment technician fit?

a)

Acceptance testing

b)

Service report

c)

Support Services

d)

Plan preventive maintenance

32.

What does a biomedical technician do?

a)

Maintain, adjust, and repair the equipment

b)

Perform for new equipment to ensure equipment meet the specifications.

c)

Schedule maintenance to ensure the clean-up and order of all equipment

33.

In what 3 locations can a biomedical equipment technician work?

a)

Stretchers, LP 12 monitors, blood glucose monitors

b)

electric wheelchairs, defibrillators, patient monitors

c)

hospitals, health care clinics, private practice offices

34.

What are the Corrective maintenance works procedure activities?

a)

Receive request. Respond to request. Evaluation & classify request. Approve request. Allocation of resources. Carry out service + Performance test + Safety test. Notify user +Arrange for delivery + User verification. Close work order file documents.

b)

Identify equipment. Prepare PPM required. Inform user. Allocation of resources. Execute PPM. User verification. Document work.

35.

What does MER mean?

__________ __________ Repairer

(a)