Phase 2 Cold Water

Total questions: 41

Worksheet time: 23mins

Name
Class
Date
1.

What is a form of non-mechanical backflow prevention

a)

Drain off valve

b)

Double Check Valve

c)

Air gap

d)

isolation valve

2.

What are the 3 types of water saving urinal flushing devices?

a)

Hydraulic impulse valve

b)

Time operated switch

c)

Sensor solenoid valve

d)

Automatic flushing syphon

3.

What is the minimum depth MDPE should be buried at?

a)

750

b)

1650

c)

850

d)

1350

4.

What are the 2 types of cold-water systems?

a)

Direct

b)

Indirect

c)

Hose fed

d)

multi fed

5.

What fluid category do washing machines and dishwashers come under?

a)

3

b)

1

c)

5

d)

4

6.

Water Regs state that a CWSC must be capable of providing Wholesome/Potable water

a)

TRUE

b)

FALSE

7.

At 4 degrees, 1 litre of water weighs 1kg

a)

TRUE

b)

FALSE

8.

How much clearance is needed above a CWSC to allow for maintenance and cleaning purposes

a)

650mm

b)

420mm

c)

350mm

d)

400mm

9.

What is the minimum distance between the F.O.V and the top of the CWSC

a)

25mm

b)

100mm

c)

75mm

d)

50mm

10.

The cold feed outlet on an indirect system should be a minimum of how high up in a CWSC

a)

25mm

b)

100mm

c)

50mm

d)

80mm

11.

The base supporting the CWSC must be 150mm larger all the way round than the base of the CWSC

a)

TRUE

b)

FALSE

12.

What is the minimum capacity for cold water only storage

a)

110L

b)

130L

c)

240L

d)

230L

13.

If a CWSC is for hot and cold storage its minimum capacity is?

a)

230L

b)

200L

c)

190L

d)

400L

14.

On a CWSC over a 1000L it must have both an overflow and a warning pipe, what is the minimum distance between the invert levels?

a)

15mm

b)

25mm

c)

50mm

d)

40mm

15.

Which BS1212 F.O.V is manufactured from plastic

a)

Part 1

b)

Part 2

c)

Part 3

16.

On an indirect system, what size pipework feeds the bath outlets

a)

15mm

b)

22mm

c)

28mm

17.

Which are the 2 advantages of a Direct system

a)

Cheaper to install

b)

No stored water

c)

Good pressure at all outlets

d)

Water hammer

18.

Which are 2 disadvantages of an indirect system

a)

Increased cost of install

b)

Stored water

c)

Less chance of backflow

d)

Larger pipework needed

19.

What is the minimum size distribution pipe from the CWSC to a hot water storage cylinder?

a)

15mm

b)

22mm

c)

28mm

d)

35mm

20.

Which Building Regs must temperature control of hot water to a bath in new dwellings conform to?

a)

Part A

b)

Part F

c)

Part G

d)

Part P

21.

Which valve must conform to BS1010

a)

Screw down stop tap

b)

Drain off

c)

Gate valve

d)

1/4 turn lever valve

22.

How should a hole be made in a CWSC for an outlet?

a)

Hole saw

b)

Warmed up copper pipe

c)

Tank cutter

d)

Pad saw

23.

What is the correct clipping distances for 15mm copper pipe

a)

Horizontal

1.2m

b)

Horizontal

1.5m

c)

Vertical

1.8m

d)

Vertical

2.1m

24.

What is the correct clipping distances for 22mm copper pipe

a)

Vertical

1.6m

b)

Horizontal

1.8m

c)

Horizontal

2.3m

d)

Vertical

2.4m

25.

Which solder should be used on a cold water system

a)

Lead Solder

b)

Lead-free Solder

26.

What fitting would be used to connect lead to copper

a)

Soldered socket

b)

Compression socket

c)

Lead Lock

d)

Push fit socket

27.

Cold water pipework should not exceed what temperature

a)

28

b)

25

c)

30

d)

20

28.

Cold water in a CWSC should not exceed what temperature

a)

15

b)

20

c)

25

d)

30

29.

When running hot and cold water pipework, which pipe should always be on the bottom

a)

Cold

b)

Hot

30.

What is the maximum depth MDPE should be buried at

a)

1450

b)

1300

c)

1350

d)

1150

31.

Where should a drain off be in a system

a)

Lowest point

b)

highest point

c)

under the floorboards

32.

What is the minimum head requirement for a gravity fed shower

a)

1,000mm

b)

1,250mm

c)

1,300mm

d)

950mm

33.

Which one of the following types of taps typically requires a single check valve to protect against backflow from cross-connection with fluid category 2 water?

a)

High neck pillar tap

b)

Bib tap

c)

Mixer tap

d)

Bi-flow mixer tap

34.

Which one of the following mechanical backflow prevention devices would be used when installing a replacement hose union bib tap?

a)

HC

b)

HUK1

c)

AG

d)

AB

35.

Fluid category 1 is best described as

a)

Slight health hazard

b)

Wholesome

c)

Aesthetically impaired

d)

Serious health hazard

36.

Fluid category 5 is best described as

a)

Serious health hazard

b)

Slight health hazard

c)

aesthetically impaired

d)

significant health hazard

37.

What fluid risk category is a kitchen sink

a)

2

b)

4

c)

5

d)

3

38.

Which air gap does an animal drinking trough use

a)

AB

b)

AG

c)

AF

d)

AUK3

39.

Which air gap is usually located at the kitchen sink

a)

Auk3

b)

Auk2

c)

Auk1

d)

HUK1

40.

If water begins to backflow upwards because of back siphonage, air will be admitted to break the siphonic action......... Which form of mechanical backflow prevention does this best describe

a)

DC pipe interrupter

b)

Double check valve

c)

non-verifiable double check valve

d)

RPZ valve

41.

How many check valves are incorporated in an RPZ valve

a)

one

b)

two

c)

three