WorksheetsELECTRICAL METHODS (IP & SP)
Total questions: 20
Worksheet time: 11mins
Which of these statements are TRUE for IP?
i. Saline water exhibit very high IP response
ii. Pyrite has higher chargeability than hematite
iii. IP effects increases with decreasing porosity
iv. IP effects decreases if water in the ground has a low conductivity
i and iii
i and iv
iii and iv
ii and iii
Which of these statements are FALSE for IP?
i. Can be surveyed with various electrode configurations
ii. Cannot detect and characterize disseminated mineralizations
iii. IP effects is greater if the metallic ore or clay is massive
iv. IP effects decreases with increasing porosity
i and iii
i and iv
iii and iv
ii and iii
Which one of these statements is FALSE?
Time domain IP method measures the resulting voltage following a change in the injected current
Injection currents for IP need to be much higher than normal DC resistivity measurement to ensure good voltage signals
Time domain IP and Frequency domain IP used the same measurement device
IP is sensitive to telluric noise
All electrode arrays used for resistivity survey can be used for IP survey as well. But there is one electrode array that is the most commonly used for IP survey. This electrode array is
Wenner array
Dipole-dipole array
Pole-dipole array
Pole-pole array
Which one of these has the lowest chargeability?
Schist
Alluvium
Gravel
Quartzites
Small semi massive sulphide bodies generally have a high IP response.
TRUE
FALSE
SP method is rank as the cheapest geophysical method.
TRUE
FALSE
The same field set up of electrical resistivity can be used to acquire for IP data too.
TRUE
FALSE
SP method does require electric current to be injected into the ground as in resistivity and IP methods.
TRUE
FALSE
SP anomalies are often interpreted quantitatively.
TRUE
FALSE
Some of the applications of SP are listed below EXCEPT:
Mapping seepage flow
Delineate shear zones
Delineate near-surface zones
Disseminated gold explorations
If you are using zinc electrode for the SP survey, which saturated solution you should use?
Copper sulphate
Zinc sulphate
Silver chloride
Which of these statements are TRUE for SP?
i. Base electrode is positive and rover electrode is negative
ii. The porous pot have no effect on the SP readings
iii. Large negative SP anomalies can be observed particularly over deposits of pyrite, chalcopyrite and magnetite
iv. SP anomalies are often interpreted by its profile shape and its amplitude
i and iii
i and iv
iii and iv
ii and iii
In ___________________ IP, it use alternating current (AC) to induce electric charges in the subsurface and the apparent resistivity is measured at different AC frequencies.
Time domain
Frequency domain
What is the unit for chargeability?
mhos/cm
ms
In SP, top of ore body is assumed to lie directly beneath the position of _________________ potential.
Maximum
Minimum
Injected current for IP survey is the same as in resistivity survey.
TRUE
FALSE
The principles types of source mechanism of SP are as follows EXCEPT:
Electrokinetic potential
Electric potential
Electrochemical potential
Mineral potential
Which are the factors that affecting SP data?
i. Power lines
ii. Temperature
iii. Ground vibration
iv. Sunlight
i, ii, and iii
ii, iii, and iv
i, ii, and iv
All of the above
SP anomalies are interpreted using these:
i. Profile shape
ii. Polarity
iii. Contour pattern
iv. Potential values
i, ii, and iii
ii, iii, and iv
i, ii, and iv
All of the above
