Worksheetsfajardo 11 plumbing ventilation
Total questions: 43
Worksheet time: 1hrs 5mins
____ of a plumbing system, is that portion of the drainage pipe installation, designed to maintain a balance atmospheric pressure inside the system to prevent problems like:
1. Trap seal loss
2. Retardation of flow
3. Deterioration of the materials
Ventilation
Pressure valve
Among the most common and serious problem being
encountered in a drainage system is the ____.
_____ can be attributed to inadequate ventilation
of the trap and the subsequent minus and plus pressures
inside the system.
Trap Seal Loss
back pressure
_____ is the result of minus pressure in the drainage system. If the trap of a common seal is open and exposed to the atmosphere, both the inlet and the outlet orifices will be under balance atmospheric pressure. As such, the tendency of water seal to move is remote.
Siphonage
Back pressure
When the water seal escape from
the P-trap, it is called ____
Trap Seal Loss.
Self Siphoning
_____ occur in unventilated traps ,which serves as oval bottom fixtures like lavatories or slop sink. Self siphonage is created when a rapid flow of water passing through the pipe siphon down the water seal inside the traps with no vent provision.
Direct or Self Siphoning
Indirect or Momentum Siphoning
____ is the result of a minus pressure in the pipe created by heavy discharge of water from a fixture installed on a line serving another fixture at a lower floor.
Indirect or Momentum Siphoning
Self siphonage
_____ is caused by plus pressure. When large
amount of water flow drops downward rapidly forming a
slug like, the air inside the pipe will be compressed
downward.
Back Pressure
Indirect or Momentum Siphoning
In the absence of adequate ventilation, the
compressed air will be forced to find its away out through a weaker point. The trap seal being the weakest point, will give way and blow out of the fixture
Back Pressure
Evaporation
This process is considered a minor problem and is less probable to drain the water inside the trap.
however, happen only on floor drain which are not regularly used to admit water, but exposed to extreme temperature.
Evaporation
Wind Effect
A wind velocity passing over the top of
the soil pipe may affect the trap seal. This kind of trap seal
loss is one improbable thing to happen by removing the
entire water seal inside the P-irap.
Wind Effect
Capillary action
This kind of trap seal loss also seldom happen and is rarely experienced by homeowners.
this action is draining of the water seal caused by foreign objects like thread or string suspended and extended over the outlet arm of the trap.
Capillary Action.
Wind effect
The vent pipe used to ventilate the soil and waste
pipes are the _____
Main Soil and Waste Vents.
soil stack and Waste branch
The main vent and other subsidiary form of relief vents, are classified according to the functions they perform, and they are called _____
This type of ventilation, only serve the fixture trap indirectly. Their main function is to maintain the balance atmospheric pressure inside the waste pipe system.
Relief and Yoke
Vent.
Vent stack ang branch vent
“ All roof exiensions of soil or waste stack shall run full
size at least _____ above the roof and when the
roof is used for other purposes than weather protection,
such extension shall not be less than _____ the
roof... the roof terminal of any stack or vent, if within 3.00
30 centimeters and
2.00 meters above
60 centimeters
and
2.00 meters above
The main vent is that potion of the vent pipe system,
serving as terminal for the smaller forms of individual and
grouped fixture trap ventilation. It is sometimes referred to
as______
Collecting Vent Line.
Terminal of vent line
The_____ is a combination of waste pipe,
vent pipe, and water supply. The efficiency of one is dependent on the other.
drainage system
plumbing system
Individual vent is sometimes referred to as _____.
It is that portion of the vent pipe system that serves as a single trap. It is connected closer to the trap directly underneath and back of the fixture, and reconnected into the main vent above the overflow line of the fixture it serves.
Back Vent
relief vent
So far, _____, is the most effective means
of venting fixture trap to prevent minus or plus pressure.
individual venting
vent with trap
No trap seal shall be placed more than _____
horizontal developed length from its vent.
1.50 meters
.6 meters
The vent opening from the soil or waste pipe, except for _____ and similar fixtures, should not be the dip of the trap.
water closets
kitchen sink
individual vent for
bathtub and shower
kitchen sink and laboratory basin
individual vent for
water closet and lavoratory
bath tub
“No vent shall be less than 38 min (1 1/2") diameter except for a 32 mm (1%") diameter _____.
waste pipe
soil pipe
The vent pipe shall be of the same diameter size as the waste pipe, and in no case must a branch or main vent have a diameter less than 1/2 that of the soil or waste pipe served, nor shall the length of a branch vent of given diameter
exceed the maximum length permitted for the main vent
serving the same size of _____.”
vent stack
branch vent
the vent pipe must rise vertically or at angle ___ to the vertical up io the point of 15 centimeters above the fixture it is venting before offsetting
horizontally or connecting to the branch main waste or
soil vent”
45°
60°
unit vent for water closet
unit vent for floor drain
is defined as; that portion of a vent pipe system that ventilates two fixture traps that discharges into a sanitary cross with deflectors.
Unit vent
back vent
It is classified as another form of individual vent, with identical form of back venting, having the same principles in functions. This type of venting is common to fixture trap serving apartment and hotel toilet particularly, on fixtures with identical position and measurements.
unit vent
yoke vent
unit vent for bathtub
individual vent for bathtub
_____ is employed where two or more
fixture traps are installed on a horizontal soil or waste
branch. Generally, the use of circuit vent reduces the cost
of plumbing installation. This type of ventilation is com-
monly used in buildings with more facilities, and battery
of fixtures.
Circuit or Loop Vent
yoke vent
On Circuit Vent for a battery of water closets, the
Code says that:
“No more than 8 water closets or other
fixtures shall be allowed on any circuit or loop vent. If
there are 14 or 16 water closets which are to be vented,
two pieces of ____ pipe should be installed.”
100 mm
150 mm
For Circuit or Loop Vents, the Code also provides that:
Circuit or Loop Vent is permitted provided that a branch
soil or waste pipe to which two and not more than ______, pedestal urinals, trap standard slop sinks, or shower stalls are connected in a series, may be vented by
a circuit or loop vent, which should be taken off in front of
the last fixture connection.
8 water
closets
6 water
closets
_____ is installed to ventilate the soil and waste
pipe and the connecting branches rather than the fixture traps.
Relief Vent
Circuit vent
Waste branches which are circuit vented, shall be
provided with ____
relief vent.
stack vent
The base of the soil stack on tall building installation is susceptible to back pressure, due to the large volume of water rushing down inside the pipe.
Hence, a ____ in this portion of the installa-
tion is necessary.
Relief Vent
circuit vent
may be installed at interval on the soil
pipe having changes in directions.
Relief Vent
Loop vent
On long vertical soil pipe, a Relief Vent is installed
at 3 to 5 floor intervals. In this manner of installation, the relief vent is sometimes referred to as
_______
Yoke or By-Pass Ventilation.
Circuit vent
Relief Vent serving a circuit vented branch, should
have at least _____the diameter of the said
soil pipe, but in no case, be less than 38 mm diameter.
one half (1/2)
one third (1/3)
For instance, if the soil pipe is 100 mm. the
relief vent is____ but in no case, be less than 38
mm diameter.
50 mm
75 mm
Yoke Vent between the main vent and the soil pipe
at 5 floor intervals must have equal pipe diameter,
as the ____.
main vent
main branch
_____ is one type of ventilation use on fixtures
in a room away from partitions. This is common to beauty parlor, barber shop, dental clinic and operating room. The use of looped vent is not practical, but sometimes tolerated, only when other methods of ventilation could not be
possible.
Looped Vent
yoke vent
The size of looped vent is also determined in the same manner as that of the ____.
individual vent
relief vent
is defined as that portion of the vent-pipe system where liquid waste regularly flows.
Wet Ventilation
dry Ventilation