Central Heating 6035-02 | Part 5

Total questions: 40

Worksheet time: 21mins

Name
Class
Date
1.

Which of the following cannot be a fuel type on a fully pumped system?

a)

Natural gas

b)

LPG

c)

Oil

d)

Solid fuel

2.

If the installation does not follow the correct sequence and the circulator works under negative pressure, what will happen if air is drawn in to the system?

a)

The system will have excess water

b)

The system will corrode

c)

The system will lack water

d)

The system will require an additional circulator

3.

Which of the following activates the hot water?

a)

Cylinder thermostat

b)

Room thermostat

c)

Programmer

d)

Boiler thermostat

4.

Which of the following is used with light low carbon steel pipes?

a)

Steam and fire systems

b)

Heating and oil lines

c)

Gas

5.

Which of the following is supplied to the property via the national grid? (Choose 2)

a)

Natural gas

b)

LPG

c)

Solid fuel

d)

Electricity

6.

Which of the following is NOT incorporated into a sealed system?

a)

Expansion vessel

b)

Filling connection

c)

Filling loop

d)

Feed & expansion cistern

7.

Which of the following systems cannot achieve the customer’s desired comfort temperature when the outside temperature is -1°C?

a)

Selective central heating

b)

Background central heating

c)

Full central heating

8.

Which of the following tends to offer background heating?

a)

Panel radiator

b)

Fan convector

c)

Skirting convector

d)

Kickspace heater

9.

What is the image shown?

a)

School grading scale

b)

Energy efficiency rating

c)

SEDBUK rating

10.

Due to resistance from pipework, fitings and/or types of bends, which of the following radiators is likely to stay cool within a system?

a)

First radiator in the circuit

b)

Third radiator in the circuit

c)

Forth radiator in the circuit

d)

Heat sink radiator in the circuit

11.

What must be installed prior to the installation of the FOV to allow for any maintenance?

a)

Single check valve

b)

Double check valve

c)

Full-way gate valve

d)

Service valve

12.

Which of the following jointing methods are not for a microbored manifold?

a)

Compression

b)

Push-fit

c)

Soldered

d)

Solvent weld

13.

What is the component shown?

a)

Automatic bypass valve

b)

Thermostatic radiator valve head

c)

Automatic air release valve

d)

Circulator

14.

In a situation in which the radiators TRV is covered by, e.g. long curtains or a sofa, what could be installed?

a)

A remote head

b)

A wheel head valve

c)

A lockshield valve

d)

None, move the obstructions (curtains/furniture)

15.

What can be added via the F&E or a radiator to protect the central heating system?

a)

Chemical inhibitor

b)

Magnetic system cleaner

c)

Anti-freeze

d)

Pipe thermostat

16.

STATEMENT: Although it is known as a 'Y-plan', it is also referred to as a 'mid-position valve'.

a)

True

b)

False

17.

What would be an advantage of having a two pipe semi gravity with heat sink?

a)

Heat control is restricted

b)

Building Regulations part L compliant

c)

Can only be used on open vented systems

d)

Possibility for system to overheat

18.

What would need to be added to the system if the property is over 150m²?

a)

An additional service valve

b)

An additional boiler

c)

An additional heating zone valve

d)

An additional cylinder

19.

If a room thermostat is installed, it must not be on an outside wall. How far up the wall should it be situated?

a)

1.5 metres

b)

2 metres

c)

3 metres

d)

4.5 metres

20.

Which of the following is an advantage to having underfloor heating?

a)

Takes longer to heat up a room

b)

Not suited for every situation

c)

Even heat over the floor area

d)

High installation costs

21.

The colour of medium graded low carbon steel is labelled as?

a)

Red

b)

Blue

c)

Brown

d)

Yellow

22.

Which of the following is NOT a disadvantage of the one pipe gravity system?

a)

Non-compliant with Building regulation Part L

b)

Uncontrolled room temperature

c)

Cheap to install

d)

Low efficiency boilers

23.

What was a 'drawback' to having a one pipe gravity system installed?

a)

Each heat emitter entered the main ring

b)

As re-enters the main ring it would cool down the flow

c)

Causing each radiator to be cooler than the one before

d)

All of the above

24.

Which of the following can be used to activate a two-port zone valve allowing circuits on either hot water or central heating? (Choose 2)

a)

Expansion vessel

b)

Circulator pump

c)

Room thermostat

d)

Cylinder thermostat

25.

Which system is recommended for larger properties?

a)

Y-plan

b)

S-plan

c)

W-plan

26.

Where would the phial be attached to that indicated when the system is up to temperature?

a)

Flow pipe of the boiler

b)

Return pipe of the boiler

c)

Open vent pipe of the F&E cistern

d)

Hot distribution pipe

27.

How far should the pipes connected to the hot water vessel, including the vent be insulated for?

a)

0.45 metres

b)

0.6 metres

c)

0.8 metres

d)

1 metre

28.

The low surface temperature radiators are not accepted in which kind of building?

a)

Nurseries

b)

Homes for the elderly

c)

Industrial factories

d)

Schools

29.

When installing an conventional boiler, which of the following components are included within the boiler?

a)

Circulator

b)

Automatic bypass valve

c)

Expansion vessel

d)

None, individual installations required

30.

Which of the following boilers use two heat exchangers to heat up the latent heat within the system?

a)

Condensing boilers

b)

Traditional boilers

c)

Convectional boilers

31.

What should be placed on a TRV when decortating is scheduled to take place?

a)

Wheel head valve

b)

Lock shield cap

c)

Decorators cap

d)

Wheel head cap

32.

The imporance of balancing the system is?

a)

The radiators need to warm up uniformly

b)

So the flow and return are not mistakenly installed backwards

c)

To meet the required 20°C temperature difference between flow and return

d)

All of the above

33.

The three port mid-position valve is labeled with AB, A and B. But what is the B for?

a)

Flow for the boiler

b)

Hot water 

c)

Central heating

34.

Which of the following can only be installed by Competent Persons?

a)

17th edition IET

b)

OFTEC

c)

HETAS

d)

All of the above

35.

STATEMENT: The F&E should be located a minimum of 1 metre above the circulator.

a)

True

b)

False

36.

You could install what alternative instead of an air separator?

a)

Galvanic cell scale inhibitor

b)

Line strainer

c)

3-port zone valve

d)

H frame configuration

37.

Which of the following is used to safely discharge the excess pressure from the expansion vessel?

a)

Automatic bypass valve

b)

Pressure reducing valve

c)

Pressure relief valve

d)

Temperature relief valve

38.

Which of the following reacts to ambient air temperature?

a)

b)

c)

39.

To prevent the possibility of back siphonage of central heating water into mains water, what is installed?

a)

Single check valve

b)

Expansion vessel

c)

Double check valve

d)

Filling loop

40.

BS 1192 recognises the symbol shown here as?

a)

Drain off valve

b)

Single check valve

c)

Automatic air vent

d)

Radiator valve