wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Central Heating 6035-02 | Part 6

Total questions: 40

Worksheet time: 21mins

Name
Class
Date
1.

To be compliant with Building Regulations part L, what type of oil boiler now needs to be installed?

a)

Combination boiler

b)

Condensing oil boiler

c)

System oil boiler

d)

Conventional oil boiler

2.

Soft coiled microbore pipes are what grade of copper?

a)

R220

b)

R250

c)

R290

3.

STATEMENT: A programmer often has a 'boost' or 'override' button to allow the system to operate outside of the programmed timings.

a)

True

b)

False

4.

What term describes, the termostat shuts the boiler down if it detects a flow above 85°C, stopping it from overheating.

a)

Locking out

b)

Aeration

c)

Bypass

d)

Zonal control

5.

The pipe that should be connected to this air separator at point A is?

a)

Open vent pipe

b)

Flow to the system

c)

Flow from the boiler

d)

Return from the boiler

6.

Which of the following is a disadvantage of the condensing boilers?

a)

Disposal of acid condensate

b)

Quiet in operation

c)

High efficiency

d)

Part L compliant

7.

In what appliance is a diverter valve commonly found?

a)

Unvented cylinder

b)

F&E cistern

c)

Combination boiler

d)

Hot water cylinder

8.

What is the component shown?

a)

Radiator key

b)

Radiator valve spanner

c)

Radiator bleed key

d)

Allen key

9.

STATEMENT: Just like the F&E cistern, the CWSC operates at atmospheric pressure due to the open vent pipe.

a)

True

b)

False

10.

Of the following locations, where would the air vents be located on a central heating system?

a)

Immediately above the circulator

b)

At the top of every radiator

c)

Just prior to each zone valve

d)

On the cold feed to the air separator

11.

What type of protection does the filling loop offer regarding protecting mains water?

a)

Single check valve

b)

Double check valve

c)

RPZ valve

d)

Air gap

12.

Upon switching off the fused spur, what else should be done to ensure a safe isolation? (Choose 2)

a)

Removal of the fuse

b)

Flushing the system

c)

Locking off the fuse holder

d)

Fill the system

13.

Which of the following is NOT an advantage of the two pipe semi gravity system?

a)

Uncontrolled heat throughout the system

b)

All heat emitters reach the same temperature

c)

It is cheaper to run

d)

Being a two pipe system, it is quicker to heat up

14.

STATEMENT: The biggest cause of corrosion within a central heating system is aeration throughout the system.

a)

True

b)

False

15.

The expansion vessel is used on a sealed system to take up the expansion of heated water. What is the percentage of water expansion?

a)

2%

b)

4%

c)

15%

d)

1600%

16.

Which of the following is commonly found with the top and side grills an optional availability on radiators?

a)

Rolled top

b)

Compact

c)

Seam top

17.

Which British Standard covers preparation, commissioning and maintenance of domestic heating and cooling water systems?

a)

BS EN 442

b)

BS EN 12828

c)

BS 7593

d)

BS EN 14336

18.

How efficient is SEDBUK rated B boiler?

a)

10-15%

b)

50-55%

c)

86-90%

d)

90-99%

19.

Approximately how much of the heat is convected via the fins welded to the back of the radiators?

a)

50%

b)

70%

c)

85%

d)

100%

20.

Which of the following require TRVs to be fitted on central heating systems? (Choose 2)

a)

Building Regs part L

b)

Compliant Persons Certificate

c)

Heating Compliance Guide

d)

Building Regs part G

21.

What system is fed from the F&E cistern which is located at a high level and can be fully pumped or gravity fed?

a)

Low pressure, open vented system

b)

Sealed, pressurised system

22.

What is the common size of the feed & expansion cistern?

a)

18 litres

b)

26 litres

c)

50 litres

d)

100 litres

23.

What tool is used to secure radiator valves in position?

a)

Radiator bleed key

b)

Adjustable spanner

c)

Radiator key

d)

Stillson wrench

24.

Building Regulations state that which of the following radiators should not contain a TRV?

a)

The radiator in the same room as the room stat

b)

The radiator that has been identified as 'index radiator'

c)

The radiator that is located in the customers "decorator room"

d)

All of the above

25.

What is the component shown here?

a)

Panel radiator

b)

Fan convector

c)

Skirting convector

d)

Kickspace heater

26.

The purpose of insulation around vulnerable areas is to? (Select 3)

a)

Stop cold getting to the pipe

b)

Stop heat leaving the pipe

c)

Stop heat transferring

d)

Stop leaks from occuring

27.

What is the 'main purpose' of central heating within a property?

a)

Providing a means of thermal comfort

b)

Heating up the primary circuit within the hot water system

c)

Provide adequate heating for one specific room

d)

To prevent other pipework within the property from freezing

28.

What would be the Delta T temperature between a system with a flow temperature of 60°C, a return temperature of 40°C, and an ambient air temperature of 20°C?

a)

10°C

b)

20°C

c)

25°C

d)

30°C

29.

Commercial insulation uses what material around the insulation to deflect heat or coldness?

a)

Lead

b)

Foil

c)

Asbestos

d)

Copper

30.

Which of the following could be used to measure the temperatures of the flow and return pipes?

a)

Digital thermostat

b)

Boiler thermostat

c)

Room thermostat

d)

Cylinder thermostat

31.

If maintenance is required on a circulator pump, what is closed to allow the pump to be removed without draining the system?

a)

The cold feed gate valve

b)

The F&E service valve

c)

The pump flanges

d)

The mains stop valve

32.

Which of the following can be caused by aeation within the heating system?

a)

Iron oxide producing magnetite

b)

System noise being heard

c)

The circulator can be burned out

d)

All of the above

33.

STATEMENT: The C plan two pipe semi gravity system was outdated by its predecessor, the two pipe semi gravity system.

a)

True

b)

False

34.

What are the clipping distances for polybutylene when water at 60°C is plumbed to pass through 15mm?

a)

Horizontal - 1.2m, Vertical - 1.8m

b)

Horizontal - 2.4m, Vertical - 3.0m

c)

Horizontal - 0.6m, Vertical - 1.0m

d)

Horizontal - 0.4m, Vertical - 0.6m

35.

The connection method for pipework to radiators that is rarely found today, except on some one-pipe systems is?

a)

TBSE : Top-Bottom-Same Ends

b)

BBOE : Bottom-Bottom-Opposite Ends

c)

TTOE : Top-Top-Opposite Ends

d)

TBOE : Top -Bottom-Opposite Ends

36.

STATEMENT: An open fire provides just as much heat throughout a property as a central heating system.

a)

True

b)

False

37.

Which of the following is installed on a fully pumped system to control the circulation of heated water?

a)

Cylinder stat

b)

Room stat

c)

Zone valves

d)

All of the above

38.

What is the maximum temperature that the cylinder thermostat is commonly set to?

a)

48°C

b)

60°C

c)

65°C

d)

80°C

39.

STATEMENT: The more columns that a column radiator has, the greater the heat output.

a)

True

b)

False

40.

What is the component shown?

a)

Panel radiator

b)

Low surface temperature radiator

c)

Skirting convector

d)

Kickspace heater