Total questions: 69
Worksheet time: 35mins
There is less vibration than from a reciprocating compressor.
Both scrolls remain stationary during operation.
There are more moving parts than in reciprocating compressors.
They are noisy.
starves the evaporator
floods the evaporator
cools the evaporator
none of the above
boiler room
furnace room
unconditioned attic
bedroom
As oulet pressure decreases
As outlet pressure increases
As oulet temperature decreases
As outlet temperature increases
It is recommended to compress the vibration absorber while installing
The flexible absorber should be fastened to the unit or to a wall at the end pointing away from the vibration source
Only one should be placed on line
They should not be placed on compressor suction lines near the condenser
decrease
increase
double
triple
manometer
hygrometer
pitot tube
anemometer
cooling system
circulating system
high side
low side
16 inches
18 inches
24 inches
30 inches
required clearances from combustible construction
type of fuel approved
control schematic
fuel rating in Btu/h
between objects that are indirectly connected
between materials that are insulated
from larger to smaller objects
from warmer to colder objects
return
supply
makeup
combustion
surge tanks
check valves
solenoid valves
two temperature valves
the flue collar of the appliance it serves
3 inches
4 inches
6 inches
240,000 BTU per day
288,000 BTU per day
300,000 BTU per day
360,000 BTU per day
saturates the evaporator with refrigerant
liquid in suction line
a high suction pressure
a starved evaporator
34 degrees F
40 degrees F
45 degrees F
55 degrees F
All louvers must have a 50% free area.
All louvers must be in a fixed open position.
Metal louvers will have a 25% free area and wood louvers will have a 75% free area.
Wood louvers will have a 25% free opening and metal louvers will have a 75% free opening.
N (nitrogen)
CH4 (methane)
CO (carbon monoxide)
CO2 (carbon dioxide)
1-1/2 inches
1-1/4 inches
2 inches
1-3/4 inches
an intermittent pilot
an interrupted pilot
a purge
an interlock
temperature and dew point
heat and cold
gain and drops
wet bulb and dry bulb
spread of smoke through the duct in an air-handling system
discharge of smoke through smoke-evacuation systems in atriums
operating temperature of unlisted high-heat solid-fuel-burning appliances
amount of smoke exhausted by commercial kitchen hood-ventilation systems
brine
an element
a refrigerant
a sodium solution
18 gauge
20 gauge
22 gauge
16 gauge
Crank the seal with a metal rod.
Tap the regulator with wrench to loosen any dust or dirt on it.
Open the valve quickly until a cracking sound is heard.
Open the valve slightly and close it immediately.
.003"
.033"
.300"
.303"
create temperature lag
short cycle
overshoot the intended destination
overcurrent
mercury switch
range adjustment
thermostatic adjustment
differential adjustment control
72 degrees F
65 degrees F
48 degrees F
32 degrees F
it changes the state of a substance without changing its temperature
it changes the temperature of a substance without changing its state
it changes both the state of a substance and its temperature
it does not change the temperature or the state of a substance
275 degrees F
255 degrees F
235 degrees F
215 degrees F
brazed joints
galvanic fittings
welded joints
di-electric fittings
5
10
15
20
the reduction of oxygen would make it hard to breath
heat generated could injure personnel
flourocarbons may become toxic
carbon monoxide may form
be drawn to scale
have three or more sets
be submitted electronically
be drawn on paper or canvas
line size and refrigerant type.
refrigerant type only.
line size only.
oil type only.
low pressure
low ambient control
discharge relief valve
crankcase pressure regulator
water cooled condenser
air cooled condenser
evaporative condenser
coil and shell condenser
hydrometer
pedometer
odometer
anemometer
The evaporator will frost.
The evaporator will have a colder temperature.
The evaporator will have a warmer temperature.
The evaporator will alternately be overfed and starved.
freon
helium
water
nitrogen
fire sprinkler piping
foam plastic insulation
pneumatic tubing
wiring
open service valves and liquid line valve
charge system
check voltage
jumper out low pressure control
be securely anchored and supported
have no more than 2 elbows
terminate within 60 inches of the floor
have a minimum diameter of 1"
0
1
2
3
Shut system down.
Install a thermostatic expansion valve.
Cycle system several times.
Service the evaporator.
file points
replace it
lubricate slide
clean terminals
electric solenoid valve
capillary tube
automatic expansion valve
thermostatic expansion valve
1/4 the amount of heat
1/3 the amount of heat
3/8 the amount of heat
1/2 the amount of heat
not be limited in length
limited to 6 feet in length
limited to 12 feet in length
limited to 15 feet in length