wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Electrical Principles 6035-02 | Part 4

Total questions: 40

Worksheet time: 21mins

Name
Class
Date
1.

Under what regulation do you as a plumber, not have to be qualified by what Building Regulation to replace a like-for-like component, unless it is in a danger zone?

a)

Part L

b)

Part P

c)

Part G

d)

Part E

2.

What is the component shown here?

a)

Pillar terminal

b)

Claw type terminal

c)

Screw/nut head terminal

d)

Strip connector

3.

The live conductor in fixed-cable installations is identified by the insulation being coloured?

a)

Red

b)

Green/yellow

c)

Blue

d)

Brown

4.

The image shown here is?

a)

TNCS from neutral

b)

TNS from armoured cable

c)

TT from electrode

5.

If a person has suffered an electric shock, who may need to be called?

a)

First aiders

b)

Qualified electricians

c)

Supervisors

6.

Which of the following is considered a danger zone in regards to the boiler?

a)

Boilers located in the loft

b)

Boilers located in the kitchen

7.

STATEMENT: A polarity test must first be carried out dead before allowing any electricity.

a)

True

b)

False

8.

What would be the resistance of a domestic appliance if the fuse size was 4 amp?

a)

76.7 ohms

b)

57.5 ohms

c)

46 ohms

d)

38.3 ohms

9.

In the case of any critical fault, who is your 'responsible person' that you must advise?

a)

First aiders

b)

Qualified electricians

c)

Supervisors

10.

The residual current breaker with overload is identified by which of the following images?

a)
b)
c)

11.

The fused spur is used to connect appliance to the ring final, giving?

a)

The correct voltage

b)

The correct ampere

c)

The safest method of resistance in the circuit

d)

A point of isolation

12.

What is the component shown here?

a)

Multimeter

b)

Manometer

c)

Socket tester

13.

For supplementary bonding the earth cable used is what size?

a)

2mm²

b)

4mm²

c)

6mm²

d)

10mm²

14.

What type of flex is used on an immersion heater?

a)

Trunking

b)

Typical flex

c)

Armoured cable

d)

Heat resistant flex

15.

Which of the following is not a result of poor workmanship?

a)

RCDs being installed

b)

Incorrect flex sizes

c)

Incorrect fuse sizes

d)

Bad installations

16.

What is the most common timer that a plumber would come across?

a)

Programmable room thermostats

b)

Central heating programmer

c)

Consumer units

d)

Astronomic timers

17.

Which of the following does not use heat resistant flex?

a)

Kettles

b)

Irons

c)

Immersion heaters

d)

Extension leads

18.

What size MCB is used in the protection of ring finals?

a)

6 amp

b)

16 amp

c)

32 amp

d)

32-45 amp

19.

Of the following, select the flush mounted switch.

a)

b)

c)

d)

20.

The maximum fuse size that a domestic 3 pin plug can have is?

a)

8amp

b)

9amp

c)

10amp

d)

13amp

21.

To protect the consumer from electric shocks, which of the following would not be used as an insulator?

a)

Rubber

b)

Plastic

c)

Glass

d)

Brass

22.

On the image displayed, what terminal is the arrow pointing to?

a)

Earth

b)

Live

c)

Neutral

23.

What size earth cable is used on cross bonding?

a)

2mm²

b)

4mm²

c)

6mm²

d)

10mm²

24.

Which of the following does not require an electrical safe isolation before any kind of work starts?

a)

Thermostats

b)

Immersion heaters

c)

Gate valves

d)

Plugs and spurs

25.

Which type of cable would large electric showers(11kW) use?

a)

1.5mm twin and earth

b)

2mm twin and earth

c)

6mm twin and earth

d)

10mm twin and earth

26.

In which current includes cathodes and anodes, in which the cathode eats away at the anode?

a)

AC - alternating current

b)

DC - direct current

27.

What must all modern circuits be protected by?

a)

An additional fuse

b)

An increase fuse size

c)

Inclusion of an RCD

d)

Replacing all MCB's with RCD's

28.

What is the use for the type of cable shown?

a)

For the use of all on-site situations

b)

Additional protection in possible vulnerability

c)

The CPC requires the use in any ceiling work

29.

The supplementary bonding earth clips are made to which British Standard?

a)

BS 6700

b)

BS 8000

c)

BS 7272

d)

BS 951

30.

What component is the arrow pointing to in the image shown?

a)

Residual current device

b)

Miniature circuit breaker

c)

Main earth bar

d)

Main consumer unit

31.

Name the major electrical control part that is missing that would exist on an S-plan system.

Programmer, Cylinder thermostat, Room thermostat, Boiler thermostat, (a)   , Zone valves.

32.

When plugging in a socket tester, how many lights should come on to confirm that the socket is 'fine'?

a)

None

b)

One, the middle light

c)

Two, both side lights

d)

All three

33.

STATEMENT: The need to remove any paint over pipework is not needed as the temporary continuity bonding clips will work sufficiently when placed over the paint, keeping the plumber safe.

a)

True

b)

False

34.

Faulty installations could lead to which of the following consequences?

a)

Fire

b)

Component failure

c)

Reduced life of components

d)

All of the above

35.

Temporary de-commissioning can be done at:

a)

The consumer unit

b)

The appliance

36.

STATEMENT: When performing safe isloation, you must prove the appliance is dead by using the voltage indicator between all combinations. L-N, L-CPC and N-CPC.

a)

True

b)

False

37.

Isolators for electric showers in the bathroom are considered to be in a 'danger zone' and will have which pull cord?

a)

Single pole isolator

b)

Double pole isolator

38.

Which of the following is described as, "the ampere and can be defined as the unit of quantity or volume passing down a conductor?

a)

Voltage

b)

Current

c)

Resistance

39.

What type of electrical component would use 2.5mm twin and earth on typical cable?

a)

Lightings

b)

Ring mains

c)

Small electric showers

d)

Larger electric showers

40.

What is the component shown here?

a)

Equipotential bonding

b)

Supplementary bonding

c)

Cross bonding

d)

Temporary continuity bonding