WorksheetsDrainage Systems 6035-02 | Part 5
Total questions: 32
Worksheet time: 45mins
Select the correct trap seal loss: When it discharges, a plug of water is formed; as the plug moves down the waste pipe, a negative pressure is created pulling the trap out.
Capillary action
Evaporation
Momentum
Self-siphonage
If a branch has a single appliance on the ventilated branch system, what size must the branch be?
25mm
28mm
32mm
40mm
Select the answer that states the disadvantage to the combined system.
Maintenance is easier
All drains are flushed by rainwater
Impossible to make an incorrect connection
More expensive for the water authority to treat the additional rainwater
The trap seal depth(mm) for washing machines or dishwashers are?
50mm
75mm
The size of waste pipe for a washing machine or dishwasher is?
32mm
40mm
75mm
100mm
In the Victorian period, what was a common material used in guttering?
Cast iron
Plastic
Asbestos
Pressed steel
The fittings must be inserted up to the this line for what reason?
Improves the efficiency
Thermal expansion
Frost condensing
What is the minimum trap seal depth for a gulley?
28mm
38mm
45mm
54mm
The component shown is?
Bath trap
Pedestal trap
In-line trap
Which part of BS EN 12056 deals with the layout and design of sanitary pipework systems?
Part 1
Part 2
Part 3
Part 4
Before you start work, what should you inspect is straight and level?
Brickwork
Fascia boards
Gutter clips
Downpipe
What is the component shown?
Bath trap
Shower trap
In-line trap
Identify the strap boss.
Disposing of any wastes needs to be done in the safest and most hygienic way to avoid?
Health problems
Customer satisfaction
Future inconveniences
Which of the following appliances does not reuse the water for grey water recycling?
Basins
Washing machines
Baths
WCs
A soil stack or section of soil stack may be taken out of service for a short period of time whilst work is carried out: is known as?
Temporary decommissioning
Permanent decommissioning
The average sized rainwater harvesting storage capacity is 5000 litres, but which of the following is not a supporting reason for having adequate capacity to cope with using the system?
Cisten capacity on the WC
Rainfall intensity
Roof area
Number of outlets
Prior to any major permanent decommissioning, what must take place?
Inform the Water Undertake
Inform the Local Authority
Do a risk assessment
Do a temporary decommission before
Select the correct component from a drain rod set: Plunger
Identify what is being represented here.
A primary ventilated stack
A secondary ventilated stack
A ventilated stub stack
A ventilated branch system
The stub stack only requires ventilation when the highest appliance is above?
1.3 metres
1.5 metres
2 metres
3.5 metres
What is the maximum length the waste pipe can be for sinks?
1.7m
3.0m
6.0mm
The component shown is specifically designed for the use on what appliance?
Sinks
WCs
Bidets
Basins
Of the following, which appliances water waste does not fall under 'foul water'?
Baths
Washing machines
Bidets
Sinks
Which of the following should this type of PPE be used when work is needed carrying out? (Choose 2)
WCs
Guttering
Kitchen sinks
Used soil stacks
Select the option that does not state a 'true' benefit to having a self-sealing waterless valve.
No water seal, no possible siphonage
Operation is louder
Gradient is not restricted
Pipework length is not restricted
Which of the following would not fall under an important activity when performing a Planned Preventative Maintenance?
Checking pipework for any leaks
Checking the domical cages and vent cowls
Lubrication of any internal threads
Reporting of any leaks to the Water Undertaker
Select the correct component: Shower trap
Select the swan neck pan connector
WRITTEN ANSWER: Fill in the missing section. (In Metres)
1.7m
3.0m
6.0m
To overcome crossflow, what size waste pipe is used for the parallel junction?
32mm
40mm
50mm
75mm
Select the correct trap seal loss: When a WC is discharged from the first floor, it falls rapidly down the soil stack.
Induced siphonage
Capillary action
Wavering out
Compression