Жұмыс парақтары26408-20 HVAC Controls
Total сұрақ: 20
Worksheet time: 10mins
The MOST widely used fossil fuel is
Coal
Fuel oil
Propane
Natural gas
Which of the following principle states that heat is created in one place, and carried to another by means of air or water?
Heat-creation principal
Heat-transfer principal
Heat-movement principal
Heat-transplant principle
The tubing that carries heat-Laden refrigerant gas from the evaporator to the compressor is known as the
Discharge line
Liquid line
Hot gas line
Suction line
A conventional thermostat should NOT be thrown into a regular trash because it
May contain mercury
Is easy to repair
Has a 10-year warranty
Contains sulfuric acid
In the cooling system, the heat exchanger where the heat absorbed by the refrigerant is transferred to the cooler outdoor air is known as a(n)
Compressor
Condenser
Evaporator
Expansion device
Automatic changeover thermostats have a minimum interlock setting, also known as the
Differential
Compensator
Deadband
Evaporator
thermostats with bimetal, sensing elements typically use a combination of copper or brass and
Elinvar®️
Nickel
Invar®️
Aluminum
If a lockout relay becomes defective, it should be replaced with an exact duplicate, sometimes called a(n)
Induced-draft relay
Control relay
Time-delay, relay
Impedance relay
The thermostat terminal that is connected to the reversing valve control, and a heat pump is
O
G
R
Y
A limit switch that senses flame outside of the heat exchanger is known as a
Rollout switch
Thermocouple
Fire stat
Thermistor
What’s freezerstat is a
Normally closed switch
Normally open switch
Digital control
thermostat that has seized
In an air-to-air heat pump Defrost is accomplished by
Placing the unit in the cooling mode
Using electric heaters to warm the outdoor coil
Running hot water over the outdoor coil
Using electric heaters to warm the indoor coil
The purpose of the defrost cycle in a heat pump is to
Warm the units circuits For optimum, electrical operation
Prevent ice buildup on the indoor coil
Prevent build up on the outdoor coil
Remove frost buildup throughout the system ductwork
Which of the following occurs as soon as heating thermostat is closed
The flame rollout switch opens
The blower fan starts
The Inducer fan starts
The inducer pressure switch opens
Which of the following is an example of an external analog device
Lights
Thermistors
Switches
Relays
NEC Article 440 Part V covers
Requirements for motor compressor controls
The control and protection of fixed electric spaces heating equipment
Digital control systems
Resistors and reactors
Which of these devices can retain a high voltage charge after power has been removed
Control relays
Capacitors used in motor circuits
Compressor contactor
Compressor terminals
If lighting units and other appliances are also supplied the rating of cord and plug connected room, air conditioners must not exceed what percentage of the branch circuit rating
10%
30%
50%
70%
When refrigeration compressions are driven by conventional, (nonhermetic) motors, the motors and controls are subject to requirements in
NEC Article 420
NEC Article 430
NEC Article 440
NEC Article 450
Connecting at 120V, heating cable to a 240V circuit will
Produce only 25% of the rated cable wattage
Melt the cable
Cause the system to operate within acceptable standards, but less than efficiency
Enable the system to operate most efficiently