wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Day 1 AP-GRAS Seminar

Total questions: 20

Worksheet time: 10mins

Name
Class
Date
1.

What is the design principle a Measurement Microphone is based on?

a)

Carbon Microphone Principle

b)

Dynamic Microphone Principle

c)

Ribbon Microphone Principle

d)

Condenser Microphone Principle

2.

What is the output of a Measurement Microphone?

a)

It´s a current output proportional to the pressure fluctuation obtained by the diaphragm 

b)

It´s a voltage output proportional to the pressure fluctuation obtained by the diaphragm 

c)

It´s a charge output proportional to the pressure fluctuation obtained by the diaphragm 

3.

What is the maximum output voltage swing of CCP Microphone Sets?

a)

28 V peak - peak

b)

8 V peak

c)

13 V peak - peak

4.

What is the microphone polarization voltage required from the DAQ/Analyzer to drive a pre-polarized microphone set?

a)

+200 VDC

b)

+100 VDC

c)

0 VDC

d)

+200 VAC

5.

The larger the diaphragm of the microphone is...

a)

The lower the sensitivity and the higher the frequency range

b)

The higher the sensitivity and lower frequency range

c)

The size of a microphone´s diaphragm has nothing to do with the sensitivity and frequency range

6.

What is a WS3F measurement microphone?

a)

It´s a 3" working standard measurement microphone according to IEC 61094

b)

It´s a 1/2" working standard free-field microphone according to IEC 61094

c)

It´s a 1/4" working standard free-field microphone according to IEC 61094

7.

. What will happen with the frequency response if you have a lot of dirt and dust on the diaphragm?

a)

The upper cut-off frequency will increase

b)

The upper cut-off frequency will decrease

c)

Nothing will happen, as the mass of the diaphragm is 100 times higher than the mass of the dirt and dust

8.

Where will you normally use a Free-Field microphone?

a)

When measuring in couplers, closed and small cavities

b)

When measuring in places with many sound sources and rooms with a lot of reverberation

c)

When measuring in anechoic chambers or typical applications requiring a sound level meter such as occupational noise

9.

Where will you normally use a Pressure microphone?

a)

When measuring in couplers, closed and small cavities and/or close to a boundary

b)

When measuring inside an anechoic chamber

c)

When measuring inside a reverberant chamber

10.

What is the consequence of blocking the venting hole of a measurement microphone?

a)

There are no consequences

b)

The microphone´s preamplifier will overheat due to lack of ventilation

c)

The microphone won´t be able to equalize the static pressure inside the mic capsule with the static pressure in the environment and the measured results will be erroneous

11.

Why do we need preamplifiers?

a)

We need them to amplify the signal to higher voltages that can be detected by the DAQ/Analyzer´s input

b)

They are not absolutely necessary if we don´t want to increase the signal gain

c)

The preamplifier converts the microphone capsule´s high impedance output into a low impedance output that can be fed into a cable and drive the input of the DAQ/Analyzer

12.

What controls the Microphone Capsule´s Low Frequency Cut-off?

a)

It is controlled by a filter in the preamplifier

b)

It is controlled by the size of the venting hole of the capsule, the smaller the venting, the lower the freq cut-off

c)

It is controlled by the capacitance of the microphone, a higher capacitance will results in a lower freq cut-off

13.

What is controlling the electrical Low Frequency Cut-off of a Microphone Set?

a)

It is controlled by the electrical design of the preamplifier

b)

It is controlled by the microphone and the size of its venting hole

c)

It is controlled by the capacitance of the microphone capsule and the input impedance of the preamplifier

14.

Which preamplifier technology will you choose if you have a Pre-polarized microphone capsule?

a)

Traditional LEMO preamplifier

b)

CCP/ICP/IEPE Preamplifier

c)

Both technologies mentioned above will work

15.

Which preamplifier technology will you choose if you have an Externally Polarized Microphone Capsule?

a)

CCP/ICP/IEPE preamplifier

b)

Traditional LEMO preamplifier

c)

Both technologies mentioned above will work

16.

What is the purpose of the TEDS technology?

a)

It stores valuable data from the sensor such as sensor type, sensitivity, calibration date, among others.

b)

It´s a technology that allows for on-site acoustical calibration of the microphone

c)

It´s a technology used to improve the frequency response of the sensor

17.

What is the highest performing AP´s audio analyzer?

a)

APx517

b)

APx555

c)

APx511

d)

APx515

18.

What is the model number of the Transducer Test Interface

a)

APx511

b)

IMP-1

c)

APx1701

d)

AUX-0100

19.

Which of the Measurements below can be performed "Open Loop"

a)

Stepped Frequency Sweep

b)

Loudspeaker Production Test

c)

Transfer Function

d)

Acoustic Response

20.

What is the name of the Utility used to combine Near Field and Far Field data

a)

MERGE

b)

SPLIT

c)

SPLICE

d)

COMBINE