Font size
WorksheetsQuizz-FT Optix Day3
Total questions: 20
Worksheet time: 10mins
You are configuring events and methods for an object in your FactoryTalkOptix project.
Which of the following statements are true about events?
An object could have more than one method, but only one event per object is configurable
Any property of an object in FactoryTalkS Optix Studio has all three
configurable events: Changed, Transitioned, and Range Transitioned Events
Any object in FactoryTalk Optix Studio contains Predefined Events
An object could have more than one event configured
In FactoryTalkOptix rproject, Which object is not containing predefined events?
Trend
Button
Panel
Rectangle
FactoryTalk Optix Studio Objects may also include properties with configurable events, except:
Modified value
Changed event
Transitioned event
Range Transioned event
You are creating a FactoryTalk& Optix project and are incorporating animations in the
graphics. Which type of animation that animated graphic object with a simple transition occuring all at the same time?
Numeric animation
Sequential animation
Parallel animation
Cutomized animation
You are creating a FactoryTalk Optix project and want to include graphic objects that can
be animated. Which of these groups you choose objects from?
Containers
Base controls
Contents
Data controls
You are configuring converters in a FactoryTalk Optix project to transform a source value
into a slope and intercept output. Which of these converters would you use to perform this
operation?
Key-value converter
Conditional converter
Linear converter
Engineering unit converter
You are configuring converters in a FactoryTalk Optix project to transform source values.
Which of these converters uses a table to perform this operation?
Engineering unit converter
Conditional converter
Key-value converter
Linear converter
You are configuring converters in a FactoryTalk Optix project. Which of these is a
necessary part to configure during the process?
Accordion
Panel
Screen
Complex Dynamic Link
You are working on a FactoryTalk Optix project and you need to access to some objects
from a remote library in a Git repository. Which of the following functionalities in the
Templates Library window allows you to do so?
Commit
Pull
Push
Add
You are in the Project View pane in FactoryTalkOptix and you wish to add an object to a
Local Library. Which of the following is the correct procedure?
In the Templates Library window, select the correct Local Library, click the Push icon, and then select the object
Drag the object to the correct Local Library in the Templates Library window
Right-click the object, then select the correct Local Library
Click Add in the Templates Library window after you have selected the object
You have created a database for a FactoryTaIk Optix project, and now want to export the
table. Which format is the correct extension for this type of action?
CSV
ACD
CRM
SQL
You are creating a database for a FactoryTalk Optix project. Which of these database types
is not recommended as a listed option for the application?
Microsoft SQL Server
MySQL
Microsoft Access
None of the answers are recommended ODBC databases
Your FactoryTalk Optix project requires using a data grid. Which of these items does the
data grid retrieve information from? (Two answers are correct.)
Project node
Trend
List box
Database
To display real time data from multiple variables at runtime. Which of the following objects would you add to plot a value on the trend chart?
Dynamic link
Label
Data grid
pen
To displays model or database data. Which of the following data control objects would you add to display 2-dimensional data in a chart?
XY chart
Histogram chart
Trend
Pie chart
Which of the following objects would you add to display alarm status at runtime?
Alarm type
Alarm variable
Alarm event
Alarm grid
you want to create instances of an alarm type that has
different values instead of creating multiple alarms. Which of the following alarms would you
create?
Level alarm
Deviation alarm
Digital alarm
Custom alarm type
You want to link an alarm to a switch. When the switch is on the alarm should show a message. Which of the following alarm options would you select?
Deviation alarm
Digital alarm
Level alarm
Rate of change alarm
Which of these is the first step in creating the logger?
Create the Event logger
Create a database
Add a data grid
Create a container
Which of these properties would be used to record only the events generated by user interactions with the application?
Non-interactive sessions excluded
Event configurations
Event Source
Locales