Gas Safety Regulations C&I l3p3/4

Total questions: 59

Worksheet time: 30mins

Name
Class
Date
1.

A separate emergency control valve is required on single cylinder installations...?

a)

True

b)

False

2.

The Gas Safety (Installation and Use) Regulations 1998 Code of Practice is approved by...?

a)

The Health and Safety Executive

b)

The Local Council

c)

British Standards

d)

The Institute of Gas Engineers and Managers (IGEM)

3.

The gas installer and the responsible person for a premise have duties to permanently identify pipework as carrying natural gas. This requirement does NOT apply to which type of premises...?

a)

Industrial gas installations

b)

Commercial installations

c)

Domestic installations

d)

Shops and offices

4.

Which one of the following is NOT defined as 'a supplier of gas'...?

a)

A landlord

b)

A person supplying gas to a premises through a primary meter

c)

A person who provides a supply of gas to a consumer by means of the filling or re-filling of a storage container

d)

A person who provides gas in a refillable cylinder

5.

According to The Gas Safety (Installation and Use) Regulations 1998, any reference to an 'appropriate standard' is a reference to any of the following which are current at the time of the work activity:

a)

A British Standard

b)

A relevant standard or code of practice of a national standards body of any n member state of the European Union (EU)

c)

Traditional procedures of manufacture of a member state of the EU where these are the subject of a written technical description sufficiently detailed to permit assessment of the goods or materials for the use specified

d)

All the above

6.

On what date did the Gas Safety (Installation and Use) Regulations 1998 come into force?

a)

1st Jan 1998

b)

31st July 1998

c)

1st October 1998

d)

31st October 1998

7.

The Gas Safety (Installation and Use) Regulations 1998 apply to 'gas fittings' used in...?

a)

Mines, quarries, agricultural premises, training and assessment establishments

b)

Self propelled vehicles, sea going ships and hovercraft

c)

Premises used for the treatment of sewage

d)

Domestic premises supplied by a gas distribution main or storage vessel

8.

Which of the following statements is INCORRECT when an LPG installation supplied by a vessel requires a regulator installing or adjusting

a)

Only the supplier can adjust and reseal the regulator

b)

Immediately after installation or adjustment the regulator is adequately sealed so as to prevent its setting from being interfered with without breaking of the seal.

c)

LPG Regulators are factory set and operatives are not allowed to break the seal, or adjust the regulator

d)

A person authorised by the supplier to act on his behalf can adjust and reseal the regulator

9.

Gas fittings shall be protected when they are exposed to environments containing...?

a)

Salt spray or corrosive chemicals

b)

Soot

c)

Dampness

d)

All of the above

10.

Which of the following statements are true in relation to existing gas fittings

a)

No person shall make any alteration to any premises if the alteration could affect the continued safe use of any gas fitting in the premises.

b)

No person shall do anything to any fitting, flue or means of ventilation which would cause the fittings etc. to constitute a danger.

c)

In relation to a place of work, an employer or self employed person shall ensure that as far as is reasonably practicable no alterations to fittings or premises shall be such that a they would constitute a danger

d)

All of the above

11.

When caravan or boat manufacturers install LPG appliances, they have the responsibilit for...?

a)

Checking that the gas fittings will not contravene the Gas Safety (Installation and Use) Regulations 1998.

b)

Checking that the gas supplies are in plastic pipework

c)

Ensuring that the caravan (or boat) will remain static for the duration of its usable life

d)

Ensuring that no gas fittings have been installed before the caravan (or boat) leaves the factory

12.

Which of the following statements is INCORRECT in relation to domestic meter installations...?

a)

A regulator must be fitted to control pressure

b)

Where the supply pressure is greater than 75mbar, a vent pipe fitted to the overpressure device must vent outside the premises

c)

A meter by-pass must always be fitted

d)

Where the supply pressure is greater than 75mbar, an over pressure shut off device must be fitted

13.

The gas supply to a fanned flued living flame gas fire correctly installed within the inner leaf of a cavity wall can be routed within the cavity provided that...?

a)

The pipe is wrapped with tape

b)

The pipe is installed in a gas tight sleeve, sealed at the point it enters the gas fire and the pipe is kept as short as possible

c)

Under no circumstances is this type of installation allowed

d)

The pipe is plastic coated and kept as short as possible and contained in a sleeve ventilated at both ends

14.

If there is a change of gas supplier to a domestic premises, who has the responsibility for updating emergency instructions / contact notices... ?

a)

The customer

b)

The Health and Safety Executive

c)

Gas Safe Register

d)

The new gas supplier

15.

The notice attached to an emergency control valve that is NOT fitted adjacent to a primary meter shall include which of the following details...?

a)

Indication that it is the gas emergency control valve

b)

How to shut off the gas supply in the event of an escape

c)

The emergency gas service contact telephone number and date the notice was attached

d)

All of the above are correct.

16.

Which of the following devices is NOT required to provide pressure protection for an LPG installation supplied by a vessel or more than two bottles... ?

a)

A device that will provide under pressure protection

b)

A device to measure the consumption of LP gas

c)

A device that will regulate the installation operating pressure

d)

A device that will provide over pressure protection

17.

Regulation 2 of the Gas Safety (Installation and Use) Regulations defines installation pipework as...?

a)

Pipework conveying gas from the meter to a gas appliance

b)

A pipe within a gas appliance

c)

A distribution main

d)

A distribution service

18.

When an operative encounters an installation where permanent equipotential bonding is missing, they should...?

a)

Ignore it

b)

Inform the customer that permanent equipotential bonding should be installed by a competent person

c)

Temporarily connect an earth cable joining together the main services of the premises

d)

Inform Gas Safe Register

19.

It is a contravention of the Gas Safety (Installation and Use) Regulations if an unqualified person...?

a)

All the above are correct

b)

Pretends to be a member of a class of persons approved by the HSE to undertake gas work

c)

Carries out gas work in domestic properties

d)

Pretends to be competent to undertake gas work

20.

A gas meter installed in premises with 2 or more floors above ground level shall not be sited...?

a)

Where it may adversely affect the escape route from a premise in the event of a fire

b)

For new installations, on or under stairways in premises where the stairway is the sole means of escape

c)

For existing installations, on or under stairways in premises where the stairway is the sole means of escape unless the meter is fire resistant or the meter is in fire resistant compartment with self closing doors, or the service is fitted with a thermal cut off device designed to stop the flow of gas if the device exceeds 950 C

d)

All of the above

21.

If an operative has reason to suspect that foreign matter may block or interfere with the safe operation of a fitting, they shall...?

a)

Inform Gas Safe Register

b)

Fit a suitable filter to the appliance inlet

c)

Fit a pressure vessel

d)

Fit a regulator

22.

You have correctly installed and commissioned a meter in a new house where the builder has already installed the pipework and appliances. What must you do next...?

a)

Issue a RIDDOR notice

b)

Leave the gas supply on and get the builder to commission the other appliances

c)

Test, purge and commission all installed pipework and appliances or seal off the supply and all outlet points

d)

Allow the customer to commission the appliances

23.

Organisations responsible for properties supplied with gas should ensure that any person they use to perform gas installation work is competent and

a)

Has at least 2 years relevant experience

b)

Has completed a relevant apprenticeship

c)

Is a member, or employed by a member of a class of persons approved by the HSE

d)

Is a member of a Trade Union

24.

An installation which contains one or more secondary meters must have?

a)

A credit meter as the primary meter

b)

A line diagram showing all meters, valves and pipework

c)

A label fitted to the primary meter showing the number of secondary meters fitted and each secondary meter needs to be labeled to show it is a secondary meter

d)

All of the above

25.

When installing a meter to a property for the first time, the engineer must ensure that the emergency control is appropriately sited, readily accessible and that...?

a)

All of the following are correct

b)

Any key or lever is securely attached and the key or lever is parallel to the pipe when in the open position and can only fall to the closed position

c)

The means of operating the key or lever to the open and closed position is permanently displayed on or near the valve

d)

Any wheel valve indicates the direction of opening and closing of the valve

26.

An employer of a person undertaking gas work shall ensure...?

a)

The person complies with the Gas Safety (Installation and Use) Regulations 1998

b)

All work is checked by the Health and Safety Executive

c)

The gas supplier is notified in writing of all work completed

d)

The person wears overalls

27.

A new meter installation shall be

a)

Fitted In a position that is readily accessible for inspection and maintenance

b)

Tested for tightness and examined to make sure that it is fitted in accordance with current regulations

c)

Purged in order to safely remove air (or purge gases)

d)

All of the above

28.

In order to carry out work on a gas fitting or storage vessel, an operative must...?

a)

Be registered with the Health and Safety Executive

b)

Be competent and a member of a class of persons approved by the Health and Safety Executive (either individually or by an employer)

c)

Be registered by the local authority

d)

Wear overalls

29.

Gas supplies may be installed through walls and floors or under the foundations of a building providing that...?

a)

They are copper

b)

The building is no more than 1 storey high

c)

They are protected against movement of the structure

d)

They are inaccessible

30.

In relation to LPG storage vessels, which of the following statements is INCORRECT...?

a)

No person may prohibit the storage of propane LPG cylinders in a cellar or basement

b)

No person shall install a gas storage vessel in a cellar or basement

c)

No person shall install an appliance fuelled by liquefied petroleum gas which has an automatic ignition device or a pilot li ht in a cellar or basement

d)

No person shall intentionally or recklessly interfere with a gas storage vessel or otherwise do anything which might affect a gas storage vessel so that the subsequent use of that vessel might cause a danger to an erson

31.

When installing gas pipework in new buildings, installers shall ensure that...?

a)

The structure is not affected and the fire resistance is not impaired

b)

All pipework and joints are concealed

c)

The pipework installed in the fabric of the building shall be plastic

d)

All pipework is surface mounted to provide for easy inspection

32.

Which of the following statements with regard to meter boxes and compounds Is correct?

a)

All of the following are correct

b)

For meter boxes and compounds that are lockable the customer must be provided with a suitably labelled key

c)

A meter box installed in or attached to the outer wall of a premise must be so constructed as to prevent any gas escaping within the box from entering the premise

d)

No person shall knowingly, store combustible materials in any meter box or meter compound

33.

When installing gas appliances, operatives shall ensure that...?

a)

All of the following conditions apply

b)

The appliance can be used without constituting a danger to any person

c)

That the appliance is not subject to any warning or prohibition notice

d)

Any second-hand or used appliance shall be verified that it is in a safe condition for further use

34.

If an appliance or fitting cannot be fully commissioned after installation or maintenance, what action must be taken...?

a)

Advise the customer to use the appliance or fitting for short periods only

b)

It must be sealed off from the gas supply with an appropriate fitting

c)

Turn off the appliance or fitting at the isolation valve

d)

The customer told not to use appliance or fitting

35.

All gas appliances shall have a means of isolation fitted to the inlet unless...?

a)

It is not reasonably practicable to fit one

b)

The appliance has a flexible connection

c)

The appliance is fitted with a multi-functional control valve

d)

A gas meter is fitted within 1m of the appliance

36.

Gas operatives cannot modify the appliance or amend or deface its data plate in a way which may affect the appliance safety... ?

a)

True

b)

False

37.

When carrying out "work" on gas appliances, in addition to checking its safe operation, gas installers shall ensure which of the following actions are examined...?

a)

All of the following should be examined

b)

The effectiveness of any flue

c)

The combustion air supply

d)

The operating pressure or heat input, or where necessary, both

38.

In what circumstances are the checks on appliances and installations as defined in Regulation 26 (9) NOT required...?

a)

When they have just been serviced

b)

If they have only just been installed

c)

When purging gas or air from an appliance or pipework has not adversely affected its safety

d)

Where the appliance or pipework installation appear to be in good condition

39.

In relation to flues for gas appliances, which of the following statements are correct...?

a)

Flues surrounded by an enclosure shall be sealed so that any spillage from the flue cannot enter any room other than where the appliance is fitted

b)

A powered flue must have a means of preventing the operation of the appliance if the flue draught fails

c)

Where a flue pipe enters a brick or masonry chimney it shall be easy to inspect

d)

All of the above

40.

Appliances installed in a bath or shower room must be....?

a)

Flueless below 7kW

b)

Room sealed

c)

Open flued below 7kW

d)

Open flued below 14kW

41.

An open flued appliance may be fitted in a bedroom providing that...?

a)

There is no restriction on open flued appliances fitted in bedrooms

b)

It is less than 14kW input and has an atmosphere sensing device fitted

c)

It has an overheat thermostat fitted

d)

It is less than 30kW input

42.

When inspecting a chimney serving a gas fire, you discover a damper plate is fitted, what action should you take...?

a)

No action is required

b)

Close it

c)

Permanently secure in the open position or remove it altogether

d)

All of the above statements are true

43.

When an operative installs a gas supply or appliance. Which of the following actions must be carried out...?

a)

Ensure that the Gas Safety (Installation and Use) Regulations 1998 have been complied with and the appliances and installations have been tested and purged

b)

Ensure manufacturers instructions have been followed and operating pressure, heat input, flue and combustion are correctly adjusted and the gas controls are tested and are working correctly and safely

c)

Ensure that all other appliances are commissioned and checked or disconnected and their connections sealed where commissioning cannot be completed

d)

All of the above actions must be completed as appropriate

44.

Where a new meter has been installed into a property that contains un-commissioned gas supplies and appliances, which of the following actions is then necessary

a)

Test and purge the meter and seal off the meter outlet with an appropriate fitting

b)

Test and purge the meter only, connect to internal pipework and leave the gas turned on

c)

Test and purge the meter only, connect to internal pipework and leave the gas turned off

d)

The meter must not be fitted

45.

A responsible person for a premise containing gas appliances/installations may be...?

a)

The occupier of the premise

b)

The owner of the premise

c)

Any person with authority for the time being to take appropriate action in relation to any gas fitting in the premise

d)

All of the above

46.

At a place of work, who has the duty for ensuring that any gas appliances, installations or flues are maintained in a safe condition...?

a)

Appliance manufacturer

b)

Installer

c)

Employer or self employed person

d)

Health and Safety Executive

47.

Regulation 36 defines a "tenant" as a person who occupies relevant premises...?

a)

where the relevant premises are occupied under a lease, the person who is entitled to the term of that lease

b)

where the relevant premises are occupied under a licence, the licensee

c)

in Scotland, the person for the time being entitled to the tenant's interest under a lease

d)

All the above

48.

Landlords must ensure that suitable checks confirming the safe operation and effectiveness of all relevant gas appliances, fittings and flues including their heat input and combustion ventilation are carried out...?

a)

by a competent person every 24 months, with records kept for 2 years

b)

by a competent person when the tenancy changes with records kept for 4 years

c)

by Local Authority Building control who keep records for a period to be determined by themselves

d)

by a competent person every 12 months with records kept for 2 years,

49.

Which of the following is NOT required by the Gas Safety (Installation & Use) Regulations 1998 to be recorded on a Landlord's Safe Report...?

a)

The name and address of the landlord

b)

The name and signature of the operative carrying out the check

c)

The tenants name(s)

d)

The name and Gas Safe registration number of the company or individual carrying out the check

50.

Where gas appliances are installed in a room that has been converted to sleeping accommodation after 1998, the landlord must ensure that...?

a)

Appliance(s) are room sealed or if open flued, below 14kw and fitted with atmosphere sensing devices

b)

The room is returned to its original use

c)

Appliances should be below 7kW heat input

d)

The landlord has no additional responsibilities if the room is converted into sleeping accommodation

51.

With regard to an escape of gas which of the following statements are CORRECT...?

a)

The supplier must stop the escape within 12 hours

b)

The responsible person for any premises must shut off the gas if he/she knows or suspects that gas is escaping

c)

If gas continues to escape or the smell persists after the gas has been shut off then the responsible person must inform the supplier of gas

d)

All of the above

52.

If a customer reports a smell of fumes from a specific appliance to the gas supplier, the gas supplier shall...?

a)

Tell the customer that it is not their problem

b)

Advise the customer on safe actions and the need to get a Gas registered business to investigate

c)

Advise the customer to install a CO detector

d)

Advise Centrica

53.

You have been called to a premise to investigate a smell of gas, after carrying out a satisfactory tightness test on the installation, the smell of gas persists. What is your responsibility

a)

Leave the gas supply on

b)

Tell the customer to call back if the smell gets stronger

c)

Do nothing if the customer accepts responsibility

d)

Inform the gas supplier

54.

Referring to Appendix 5 of the Gas Safety (Installation and Use) Regulations, which of the following letters indicate the correct position for an emergency meter control valve when the meter is fitted INSIDE the property...?

a)

A

b)

B

c)

C

d)

D

55.

Referring to Appendix 5 of the Gas Safety (Installation and Use) Regulations, which of the following letters indicate the correct position for an emergency meter control when the meter is fitted OUTSIDE the property, for example in a meter box... ?

a)

A

b)

B

c)

C

d)

D

56.

Referring to Appendix 5 of the Gas Safety (Installation and Use) Regulations, which of the following letters indicate the correct position(s) for an emergency meter control in blocks of flats where the service enters through the basement and then rises through the flats INSIDE the property

a)

A & B

b)

A & C

c)

B & C

d)

B & D

57.

Referring to Appendix 5 of the Gas Safety (Installation and Use) Regulations, which of the following letters indicate the correct position(s) for an emergency meter control in blocks of flats where the service runs up the OUTSIDE wall of the property and then enters each fiat separately

a)

A

b)

B

c)

C

d)

D

58.

Referring to Appendix 5 of the Gas Safety (Installation and Use) Regulations, which of the following letters indicate the correct position(s) for an emergency meter control in blocks of fiats where the meter is fitted away from the flat, for example in a meter house or basement...?

a)

A & B

b)

A & C

c)

B & C

d)

B & D

59.

Referring to Appendix 5 of the Gas Safety (Installation and Use) Regulations, which of the following letters indicate the correct position for an emergency meter control on the LPG installation...?

a)

A

b)

B

c)

C

d)

D