Level 2 - Central Heating MEGA QUIZ

Total questions: 62

Worksheet time: 34mins

Name
Class
Date
1.

Which document gives advice on how to satisfy the requirements of L1a and L1b regarding the design efficiency of domestic CH systems?

a)

BS EN 442

b)

BS EN 12828

c)

Manufacturers’ instructions

d)

Domestic Heating Compliance Guide (DHCG)

2.

What is the main purpose of central heating?

a)

To provide cooling in every room

b)

To provide lighting in every room

c)

To provide ventilation in every room

d)

To provide thermal comfort within a property

3.

When the outside temperature is −1⁰C, what type of central heating allows all rooms in a property to be heated at the same time to a specific temperature set by the customer?

a)

Full central heating

b)

Background central heating

c)

Pumped heating with gravity hot water

d)

Selective central heating

4.

What type of system is installed mainly on a cost basis and uses a smaller boiler or heat emitters to only take the chill out of the rooms and heat the rooms to a lower temperature?

a)

Sealed, pressurised systems

b)

Pumped heating with gravity hot water

c)

Background central heating

d)

Fully pumped system

5.

What has central heating been replaced with over the past 10 years?

a)

Open fire in each room

b)

Gravity hot water system

c)

heat pumps

d)

Electric storage heaters

6.

What type of modern domestic central heating system is fed from a feed-and-expansion cistern located at high level?

a)

Sealed, pressurised systems

b)

Low-pressure, open-vented systems

c)

Fully pumped system

d)

Pumped heating with gravity hot water

7.

What type of modern domestic central heating system is fed directly from the mains cold water and incorporates an expansion vessel to take up the expansion of the heated water?

a)

Low-pressure, open-vented systems

b)

Sealed, pressurised systems

c)

Fully pumped system

d)

Pumped heating with gravity hot water

8.

What is the advantage of a C plan two-pipe semi-gravity central heating system?

a)

Not compliant with Building Regulations L1b

b)

Limited control on heating and hot water

c)

Lower efficiency

d)

Quicker heat-up time and compliant to building regulations L1B

9.

What is the purpose of a heat sink in a two-pipe semi-gravity central heating system?

a)

To increase the efficiency of the boiler

b)

To regulate the air pressure in the system

c)

To control the flow and return temperature

d)

To dissipate heat without overheating the boiler

10.

What type of system uses a pump to circulate heated water around the hot water and heating circuits?

a)

C plan two-pipe semi-gravity

b)

Two-pipe semi-gravity with heat sink

c)

Pumped central heating only

d)

Fully pumped systems

11.

What is the purpose of an automatic bypass valve in a fully pumped mid-position valve system?

a)

To prevent lock out and prolong circulator life

b)

To control the flow of water to the hot water cylinder

c)

To increase the system pressure when circuits close down

d)

To isolate the flow of water

12.

Which type of system uses one zone valve to control the hot water and a second zone valve to control the heating circuit?

a)

Fully pumped two two-port valves – S plan system

b)

Fully pumped mid-position valve – Y plan system

c)

Pumped central heating only

d)

Two-pipe semi-gravity with heat sink

13.

What is the purpose of locking out in a boiler?

a)

To increase the efficiency of the boiler

b)

To regulate the air pressure in the system

c)

To protect the boiler from overheating

d)

To control the flow and return temperature

14.

What is the cause of corrosion within a central heating system?

a)

Aeration

b)

Overheating

c)

Low system pressure

d)

Excessive water flow

15.

What is the purpose of a sealed expansion vessel in a sealed heating system?

a)

To isolate the flow of water

b)

To prevent lock out and prolong circulator life

c)

To control the flow of water to the hot water cylinder

d)

To accommodate the increase in volume as the water heats up

16.

What is the purpose of a pressure relief valve in a sealed heating system?

a)

To discharge pressure to a safe location if required

b)

To isolate the flow of water

c)

To prevent lock out and prolong circulator life

d)

To control the flow of water to the hot water cylinder

17.

What is this component called

a)

Central heating booster pump

b)

Central heating circulation pump

c)

Central heating control valve

d)

Shower booster pump

18.

What building regulation covers central heating systems?

a)

Part G

b)

Part L

c)

Part A

d)

Part H

19.

The main problem with the one pipe system is that

a)

They are prone to blockages

b)

They can't be used in a bungalow

c)

They are expensive to run

d)

The earlier radiators pass cooler water back into the circuit

20.

When positioning a single room thermostat, it’s recommended height from ground level is

a)

1m

b)

1.5m

c)

2m

d)

2.5m

21.

When setting the water level in a feed and expansion cistern, the allowance that should be

made for the expansion of water in the heating system is

a)

4 %

b)

6 %

c)

10 %

d)

1600 times its volume

22.

The recommended test pressure for a hydraulic test on a central heating system is

a)

normal working pressure

b)

1.5 times normal working pressure

c)

twice the normal working pressure

d)

3 bar pressure

23.

What is the image shown used for?

a)

Clearing the pump

b)

Venting the boiler interlock

c)

Charging the radiators

d)

Bleeding the radiators

24.

What is this

a)

TRV

b)

Bypass valve

c)

Thermostatic mixing valve

d)

High temperature relief valve

25.

What does this component do?

a)

controls the hot water temperature

b)

controls the room temperature

c)

controls the boiler

d)

none of the above

26.

What type of system is this?

a)

C plan

b)

Y plan

c)

S plan plus

d)

S plan

27.

Name the component

a)

programmer

b)

cylinder thermostat

c)

boiler thermostat

d)

room thermostat

28.

name the component

a)

wheel head radiator valve

b)

thermostatic radiator valve

c)

lock shield radiator valve

d)

gate valve

29.

What type if radiator can you see?

a)

single panel

b)

double panel

c)

double panel single convector

d)

column radiator

30.

What is this component used for?

a)

connecting to taps

b)

connecting cold water to a central heating system to fill

c)

connecting to an expansion vessel

d)

back flow prevention device

31.

What kind of boiler can you see here?

a)

system boiler

b)

conventional boiler

c)

combination boiler

d)

thermal store

32.

A property above how many m2 should have more than 1 zone?

a)

100 m2

b)

150 m2

c)

200 m2

d)

250 m2

33.

A heating system not open to the atmosphere is know as a?

a)

Un vented system

b)

Mains feed system

c)

Sealed system

d)

Fully pumped system

34.
Question Image

Match the following

a)

A

1.

System under negative pressure

b)

B

2.

System under positive pressure

c)

C

3.

Correct arrangement

35.

What type if radiator can you see?

a)

single panel

b)

double panel

c)

double panel single convector

d)

column radiator

36.

A drawback to a one pipe system is?

a)

It is expensive to install

b)

The radiators get too hot

c)

The return water travels to the following radiator

d)

It needs 2 F&E cisterns

37.

Match the following Heat exchangers to the correct boiler description

a)
1.

Regular Boiler

(BBU)

b)
2.

Regular Boiler (System)

c)
3.

Instantaneous (Combi Boiler)

d)
4.

Storage (Combination Boiler)

38.

What is the purpose of a Thermostatic valve on a radiator

a)

To control the temperature of the water in the radiator

b)

To turn off the radiator when the air temperature in the room is at the required level according to the setting on the valve head

c)

To turn off the radiator when the air temperature in the room is at the required level according to the room thermostat

d)

To turn on the radiator when the air temperature in the room is at the required level according to the setting on the valve head

39.

What is the name of this heating component

a)

Feeling loop

b)

Pressure loop

c)

Hula hoop

d)

Filling loop

40.

What is the name of this type of heating system

a)

Two pie

b)

Reversed return

c)

One pipe

d)

Secondary circulation

41.

What does a Magnaclean do

a)

Removes limescale in a boiler

b)

Remove iron oxides

c)

Collects iron oxide

d)

Reduces magnetic fields in a system

42.

What one of these components is NOT installed on a sealed heating system

a)
b)
c)
d)
43.

Which of the following types of heat emitters potentially has blocked fins due to dust build-up?

a)

Skirting convector

b)

Fan convector

c)

Kickspace heater

d)

LST radiators

44.

Which of the following is not a variation of connections for the radiator valves?

a)

TBOE

b)

BBOE

c)

TBSE

d)

TTOE

45.

The diagram shown can be identified as:

a)

Insulation plan

b)

Floor layout

c)

Underfloor heating system

d)

Trace heating system

46.

One radiator in the circuit must be left without a TRV fitted. Building Regulations state it should be the:

a)

Bathroom radiator

b)

Hallway radiator

c)

Front room radiator

d)

Kitchen radiator

47.

What is the cause of corrosion within a central heating system?

a)

Aeration

b)

Overheating

c)

Low system pressure

d)

Excessive water flow

48.

Which one of the following would be included in a sealed central heating system?

a)

Expansion Vessel

b)

F& E System

c)

Pressure reducing valve

d)

Cold Water Storage Cistern

49.

when balancing a central heating system, what is the design temperature drop between flow and return pipework?

a)

20°c

b)

15°c

c)

4°c

d)

4.2°c

50.

When setting the water volume in an F and E cistern, what allowance should be made for expansion of water?

a)

2.5%

b)

4%

c)

10%

d)

12%

51.

What is the disadvantage of a two-pipe semi-gravity system in terms of heat control?

a)

Uncontrolled heat

b)

Controlled heat

c)

Heat is not distributed evenly

d)

Heat emitters do not reach the same temperature

52.

What is the advantage of a two-pipe semi-gravity system in terms of heat emitters?

a)

Heat emitters are not efficient

b)

All heat emitters reach the same temperature

c)

All heat emitters have different temperatures

d)

Heat emitters are not affected by the system

53.

What is the recommended minimum height for the open vent pipe in a one-pipe semi-gravity system?

a)

350mm

b)

450mm

c)

250mm

d)

150mm

54.

What is the primary function of the open vent pipe in a one-pipe semi-gravity system?

a)

To discharge steam/water in a fault condition

b)

To allow filling of the system from the F&E cistern

c)

To control room temperature

d)

allow for expansion and contraction to provide a safety outlet in case of overheating

55.

What is the drawback of a one-pipe semi-gravity system in terms of the temperature of each radiator?

a)

The temperature of the radiators is unpredictable

b)

Each radiator is progressively hotter than the previous

c)

Each radiator is progressively cooler than the previous

d)

All radiators have the same temperature

56.

Which radiator is a double panel double convector

a)
b)
c)
d)
57.

Balancing a heating system requires you to adjust what

a)

The thermostat

b)

The TRV

c)

The lock shield

d)

The thermometer

58.

Where is the neutral point

a)

At the edge of the Klingon empire

b)

Where the open vent connects to the circuit

c)

Where the primary flow becomes the return

d)

Where the cold feed connects to the circuit

59.

The main problem with the one pipe system is that

a)

They are prone to blockages

b)

They can't be used in a bungalow

c)

They are expensive to run

d)

The earlier radiators pass cooler water back into the circuit

60.

The cold water supply to a fully pumped open vented central heating system should be

isolated at the

a)

stop valve to the incoming cold water supply pipework

b)

Gate valve on the cold feed pipework from the F & E cistern

c)

service valve to the float operated valve to the CWS cistern

d)

service valve to the float operated valve to the F & E cistern.

61.

When setting the water level in a feed and expansion cistern, the allowance that should be

made for the expansion of water in the heating system is

a)

4 %

b)

6 %

c)

10 %

d)

1600 times its volume

62.

Gas Boilers should be installed by someone registered with

a)

Gas Safe

b)

HETAS

c)

OFTEC

d)

Ofsted