wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Central Heating revision | 6035

Total questions: 22

Worksheet time: 12mins

Name
Class
Date
1.

Identify what type of system is shown here.

a)

C plan plus

b)

Semi gravity system

c)

Unvented system

d)

Full gravity pumped system

2.

To conform with European standard, all radiators manufacture must comply with:

a)

BS 4422

b)

BS 6700

c)

BS EN 442

d)

BS EN 104

3.

The type of system shown can be identified as?

a)

W-plan system

b)

S-plan system

c)

Y-plan system

d)

Combination boiler system

4.

On a three port mid-position valve, what does port 'A' supply?

a)

The boiler

b)

Central heating circuit

c)

F&E cistern

d)

Hot water circuit

5.

The most common arrangement of radiator valve is:

a)

BBOE

b)

TBOE

c)

TBSE

d)

TTOE

6.

The type of radiator shown here is?

a)

Double panel with single convector

b)

Single panel with double convector

c)

Double panel

d)

Single panel with single convector

7.

Dependant of the skirting, what is the typical height that you should install radiators from floor level?

a)

100mm

b)

150mm

c)

200mm

d)

250mm

8.

The symbol shown here can be identified as?

a)

Single check valve

b)

Double check valve

c)

Service valve

d)

Circulator

9.

How does the component circled here work?

a)

Filling loop - Allows the boiler to be topped up when the pressure has dropped

b)

Pressure relief valve - Relieves the system of any build-up of pressure

c)

Bypass valve - Allows a flow of water through a boiler to reduce the chance of over-heating

d)

Automatic air vent - Allows the air within the system to be released through all high points

10.

The diagram shown can be identified as?

a)

Unvented system

b)

Semi gravity system

c)

Combination boiler

d)

Fully pumped system

11.

If the circulator is installed after the vent pipe but before the cold feed, what error has occurred?

a)

The system is working under negative pressure, pushing water back into the cistern

b)

The system is working under positive pressure, pushing water back into the cistern

c)

The system is working under negative pressure, pumping over the vent pipe

d)

The system is working under positive pressure, pumping water to the neutral zone

12.

Although not the most common arrangements of radiator valves, the most efficient setup is?

a)

TBSE

b)

TTOE

c)

BBOE

d)

TBOE

13.

The most common material used for insulation is?

a)

Felt lagging

b)

Polyester

c)

Fibreglass

d)

Asbestos

14.

The type of radiator shown here is?

a)

Column radiator with towel rail

b)

Fan convector with towel rail

c)

LST radiator with towel rail

d)

Panel radiator with towel rail

15.

Building Regulations part L covers the conservation of fuel and energy. What is the Northern Ireland equivalent?

a)

Specific Guidance part L

b)

Technical Guidance part L

c)

Regulated Guidance part L

d)

Building Guidance part L

16.

The function of the zone valves is?

a)

To allow simultaneous control of both hot water and central heating circuits

b)

To allow control for either hot or cold water circuits

c)

To allow control of either hot water or central heating circuits

17.

Before work commences, what procedure must be carried out?

a)

Informing the customer of the water being shut off

b)

Safe isolation procedure

c)

Boiler interlock procedure

d)

Thermal lockout procedure

18.
a)

W-plan system

b)

S-plan system

c)

Y-plan system

d)

Combination boiler system

19.

The component circled can be identified as?

a)

Automatic air vent

b)

Expansion vessel

c)

Automatic bypass valve

d)

Filling loop

20.

Domestic steel pipework would be:

a)

Light grade

b)

Medium grade

c)

Heavy grade

21.

A 22mm copper pipe on the central heating system would be:

a)

R220

b)

R250

c)

R290

d)

R300

22.

On a W-plan or combination boiler, what would the three-port diverter valve give water priority to?

a)

Cold water

b)

Central heating

c)

Hot water

d)

Primary flow