1.

When installing plastic materials it is important we allow for......

a)

time to install them correctly.

b)

expansion of the plastic.

c)

the correct jointing method.

d)

the right type of plastic.

2.

The main purpose of a dual flush WC cistern is to

a)

increase the volume of water to flush the pan

b)

allow the cistern to be connected to a siphonic pan

c)

prevent the possibility of the cistern overflowing.

d)

significantly improve water conservation

3.

What is the recommended flushing volumes of a dual flush wc cistern

a)

6 and 5 litres

b)

6 and 4 litres

c)

8 and 4 litres

d)

9 and 4.5 litres

4.

Name the flushing mechanism in the cistern shown.

a)

Siphon flushing mechanism

b)

Drop valve flushing mechanism

c)

Air valve flushing mechanism

d)

Electronic valve flushing mechanism

5.

Name the WC Pan shown

a)

Washdown pan with single trap

b)

Double trap siphonic pan

c)

Single trap siphonic pan

6.

Name the WC Pan shown

a)

Washdown pan with single trap

b)

Double trap siphonic pan

c)

Single trap siphonic pan

7.

Name the WC Pan shown

a)

Washdown pan with single trap

b)

Double trap siphonic pan

c)

Single trap siphonic pan

8.

Which part of the Bulding Regulations Approved Documents deals with the installation of Sanitary pipework?

a)

Approved document B

b)

Approved document E

c)

Approved document G

d)

Approved document H

9.

This picture shows a?

a)

Waste manifold

b)

Long radius bend

c)

Strap boss

d)

intumescent collar

10.

The lowest connection to the soil stack must be a minimum of how many mm for a two story building?

a)

150 mm

b)

300 mm

c)

450 mm

d)

750 mm

11.

What is the name of the section referred to in the image shown?

a)

The vent pipe

b)

The soil pipe

12.

Select the correct PVCu profile: Half round

a)

b)

c)

d)

13.

Identify the diagram shown.

a)

A primary ventilated stack

b)

A secondary ventilated stack

c)

A ventilated branch system

d)

A stub stack

14.

Identify this stack system

a)

Stub System

b)

Primary Stack System

c)

Secondary Ventilated System

d)

Ventilated Discharge Branch system

15.

Identify this stack system

a)

Stub System

b)

Primary Stack System

c)

Secondary Ventilated System

d)

Ventilated Discharge Branch system

16.

Identify this stack system

a)

Stub System

b)

Primary Stack System

c)

Secondary Ventilated System

d)

Ventilated Discharge Branch system

17.
  1. Identify this below ground drain system

a)

Combined system

b)

Separate system

c)

Partially separate system

18.
  1. Identify this below ground drain system

a)

Combined system

b)

Separate system

c)

Partially separate system

19.
  1. Identify this below ground drain system

a)

Combined system

b)

Separate system

c)

Partially separate system

20.

Where does the overflow normally discharge to in a new WC fitted with a drop valve mechanism?

a)

To the outside air

b)

To the toilet pan

c)

To the toilet cistern

d)

   To the basin waste

21.

What type of sanitary pipework system will normally be used in a two storey house with all appliances closely grouped around the stack?

a)

Primary ventilated stack system

b)

Secondary ventilated stack system

c)

Ventilated branch discharge system

d)

Stub stack system

22.

What is the maximum length of a WC branch?

a)

2m

b)

4m

c)

6m

d)

8m

23.

What is the Trap Seal Depth when fitted to a primary ventilated system (BS EN 12056-02) of a Wash Basin pipe size of 32mm Diameter

a)

75mm

b)

50mm

c)

25mm

d)

100mm

24.

What is the Trap Seal Depth when fitted to a primary ventilated system (BS EN 12056-02) of a Bath pipe size 40mm Diameter

a)

75mm

b)

50mm

c)

25mm

d)

100mm

25.

The lowest connection to the soil stack must be a minimum of how many mm for a two story building?

a)

150 mm

b)

300 mm

c)

450 mm

d)

750 mm

26.

Name the flushing mechanism in the cistern shown.

a)

Siphon flushing mechanism

b)

Drop valve flushing mechanism

c)

Air valve flushing mechanism

d)

Electronic valve flushing mechanism

27.

Name the flushing mechanism in the cistern shown.

a)

Siphon flushing mechanism

b)

Drop valve flushing mechanism

c)

Air valve flushing mechanism

d)

Electronic valve flushing mechanism

28.

A kitchen sink waste should use what size waste pipe

a)

50mm

b)

32mm

c)

40mm

d)

110mm

29.

What size waste pipe is used to connect a bath waste to a soilstack

a)

110mm

b)

32mm

c)

40mm

d)

50mm

30.

The size of a waste pipe for a soilstack is

a)

110mm

b)

50mm

c)

32mm

d)

40mm

31.

On a ventilated branch system, each branch is ventilated no more than how far from the appliances?

a)

500mm

b)

750mm

c)

1000mm

d)

1250mm

32.

What is shown in the image?

a)

Stop Valve

b)

Water Valve

c)

AAV

d)

Max Trap

33.

How is trap seal loss measured?

a)

Using a take measure

b)

Using your finger

c)

Using a plunger

d)

Using a dipstick

34.

Identify the type of trap

a)

P trap

b)

S trap

c)

running trap

d)

bath trap

35.

Identify the type of trap

a)

P trap

b)

S trap

c)

running trap

d)

bath trap

36.

Identify the type of trap seal loss

a)

compression

b)

wavering out

c)

capillary action

d)

momentum

e)

self siphonage

37.

Identify the type of trap seal loss

a)

compression

b)

wavering out

c)

capillary action

d)

momentum

e)

self siphonage

38.

Identify the type of trap seal loss

a)

compression

b)

wavering out

c)

capillary action

d)

momentum

e)

self siphonage

39.

Identify the type of trap seal loss

a)

compression

b)

wavering out

c)

capillary action

d)

momentum

e)

self siphonage

40.

Identify the type of trap seal loss

a)

evaporation

b)

wavering out

c)

capillary action

d)

momentum

e)

induced siphonage

41.

Identify the type of trap seal loss

a)

evaporation

b)

wavering out

c)

capillary action

d)

momentum

e)

induced siphonage

42.

Identify the type of trap seal loss

a)

evaporation

b)

wavering out

c)

capillary action

d)

momentum

e)

induced siphonage

43.

What is shown in the image?

a)

Pigmy Trap

b)

Straight Trap

c)

Waterless Trap

d)

French Flange Trap

44.

What is shown in the image?

a)

P Trap

b)

S Trap

c)

Bath Trap

d)

Running Trap

45.

What is the Trap Seal Depth when fitted to a primary ventilated system (BS EN 12056-02) of a Bath pipe size 40mm Diameter

a)

75mm

b)

50mm

c)

25mm

d)

100mm

46.

What is the Trap Seal Depth when fitted to a primary ventilated system (BS EN 12056-02) of a Wash Basin pipe size of 32mm Diameter

a)

75mm

b)

50mm

c)

25mm

d)

100mm

47.

This picture shows a?

a)

Waste manifold

b)

Long radius bend

c)

Strap boss

d)

intumescent collar

48.

This picture shows a?

a)

Waste manifold

b)

Long radius bend

c)

Strap boss

d)

intumescent collar

49.

This picture shows a?

a)

Waste manifold

b)

Long radius bend

c)

Strap boss

d)

intumescent collar

50.

The fall on a soil stack must be?

a)

90 degrees

b)

45 degrees

c)

Self cleaning

d)

7 mm per metre

51.

What should be the minimum pipe size used if multiple appliances are connected to a single discharge pipe?

a)

32mm

b)

40mm

c)

50mm

d)

60mm

52.

What can assist with the problem of trap seal loss due to wind?

a)

Tightening the pipes

b)

Installing a wind cowl

c)

Using heavier water

d)

Decreasing the size of the soil stack

53.

What causes the water levels in the appliance traps to bob up and down, leading to trap seal loss?

a)

Changes in water temperature

b)

Wind passing over the top of a soil stack

c)

Clogs in the plumbing system

d)

Faulty plumbing fixtures

54.

Which of the following is not a reason for trap seal loss?

a)

Momentum

b)

Compression

c)

Self-siphonage

d)

Water filtration

55.

What is the minimum distance from the permitted opposing connection in the soil stack to the branch connection?

a)

200mm

b)

250mm

c)

300mm

d)

2.5 times the diameter of the pipe

56.

How does a self-sealing waterless valve function after the discharge has finished?

a)

The membrane remains open

b)

The membrane closes

c)

The valve seals with water

d)

The valve releases water

57.

Why are bottle traps not suitable as a sink trap?

a)

They are too large for a sink.

b)

They are not visually appealing.

c)

They are restrictive to the flow of water.

d)

They are too expensive.

58.

What is the trap shown on the left side of the image called?

a)

P-trap

b)

Bottle trap

c)

Slimline 'S' trap

d)

Running trap

59.

When is a 'P' trap commonly installed?

a)

When the discharge branch is vertical to the appliance

b)

When multiple appliances are served by one discharge branch

c)

When the discharge branch is horizontal to the appliance

d)

When the initial waste pipe is vertical

60.

When doing a soundness test, how long do you need to test for?

a)

15 mins

b)

1 hour

c)

3 mins

d)

2 mins

61.

When carrying out a soundness test, what level should the water in the gauge be at?

a)

38mm

b)

40mm

c)

32mm

d)

3mm

62.

What testing instrument is used for a soundness test?

a)

Medium

b)

Manometer

c)

Multimeter

d)

Analyser

63.

Which test checks that trap seal depth is maintained?

a)

Leak test

b)

Tightness Test

c)

Soundness Test

d)

Performance Test

64.

What is the minimum trap seal depth permitted after testing?

a)

75mm

b)

32mm

c)

50mm

d)

25mm

65.

How many times should a performance test be carried out?

a)

3 times

b)

Once

c)

Twice

d)

4 Times

66.

What is the purpose of a stub stack in plumbing?

a)

To provide ventilation to the appliances

b)

To allow appliances to be connected directly to the drain

c)

To measure the water pressure

d)

To prevent water from flowing back into the appliances

67.

Where can a soil stack terminate?

a)

Inside the loft area

b)

Outside the property to atmosphere

c)

Both inside the loft area and outside the property to atmosphere

d)

None of the above

68.

When installing gutter angle fittings, how far should stop ends and unions, fascia brackets be fitted from these fittings to provide additional support?

a)

Within 50mm of either side

b)

Within 150mm of either side

c)

Within 250mm of either side

d)

Within 350mm of either side

69.

What is the first step in the gutter installation process according to the document?

a)

Measure the overall length of the gutter

b)

Establish the position of the outlet

c)

Tie a string line on the first fascia bracket

d)

Fix the first fascia bracket at the high position of the gutter

70.

What should be done after establishing the high position of the gutter?

a)

Measure the overall length of the gutter

b)

Establish the position of the outlet

c)

Tie a string line on the first fascia bracket

d)

Fix the first fascia bracket at this point

71.

How should the fall of the gutter be calculated?

a)

Using a 1:200 fall

b)

Using a 1:600 fall

c)

Using a 1:400 fall

d)

Using a 1:800 fall

72.

The gradient for a bath waste should be between?

a)

18 - 90

b)

18 - 22

c)

18

d)

18 - 75

73.

No connection are allowed to be made opposite a WC connection within how many mm?

a)

150

b)

200

c)

250

d)

300

74.

A soil pipe must rise at least 900 mm above a window when it is within?

a)

1 m

b)

1.5 m

c)

2.5 m

d)

3 m

75.

The building regulation that covers drainage is?

a)

F

b)

H

c)

G

d)

A