WorksheetsSivacon S8 Training Test
Total questions: 10
Worksheet time: 10mins
What is the meaning of MCC in typical LV switchboard cubicle?
Mounting Control Center
Motor Control Center
Module Control Center
Medium Control Center
What more attention during operated withdrawable units Sivacon S8?
Special keys & Rotary drive handle Off position
Area clean from materials
Special tool bag
Permit Works
While open the door withdrawable units, how indicator position withdrawable units?
Test Position
Connect Position
Disconnect Position
Mounting door to be closed
What to do while withdrawable units got problem during operation?
I don’t care
Make reported and call EHS team
Check alarm at location cubicle withdrawable units, Off ACB Breaker incoming cubicle & Off rotary drive handle disconnect or rack out withdrawable units & make report as investigation
Check Drawing
Withdrawable units on position(energizing), what to do if withdrawable units can’t open the door after off (disconnect position) emergency situation?
Use small pin & inserted to lower hole at rotary drive handle withdrawable units
Call Siemens representative and assignment to site location
Rotary drive handle to be check & Off position
Rotary drive handle to be check & Test position
What excellence Universal mounting design & Vertical distribution busbar at LV switchboard Sivacon S8?
A. Very difficult installation during process at site
B. Easy modified if any additional load in the future
C. Manifold connection optional for cubicle and busbar without drilling or punching
D. point B and C are correct answer
Sivacon S8 as new product by Siemens, what is applicable for this product?
A. Sivacon S8 are cubicle system for control, protection motor & safe running motor easy operated
B. Infrastructure applications (E.g. Building technology)
C. Process Industry (E.g. Chemical, Oil & Gas)
D. point B and C are correct answer
Power system LV Switchboard Sivacon S8, applicable for?
A. Phase to phase
B. Phase to neutral
C. 3 Pole and 4 Pole
D. point A, B, C are correct answer
How is universal mounting design in Sivacon S8?
Combination of various installation system, Fix mounted design withdrawable units and cable connection from the top, bottom and rear
Combination of various installation system
Fix mounted design
Medium Voltage System (MV)
Sivacon S8 is new product by Siemens very easy for modification required, how is engineering system usually in Sivacon S8?
A. Typical MCC use simocode for protection motor, main distribution board (MDB)
B. Communication system use profibus, modbus & profinet
C. Voltage system 400 Volt & 690 Volt AC
D. point A, B, C are correct answer
