central heating advanced questions

Total questions: 71

Worksheet time: 38mins

Name
Class
Date
1.

What type of boiler is this

a)

A system boiler

b)

A hot water only boiler

c)

Central heating only boiler

d)

A combination boiler

2.

What are these components called and what are they used for

a)

Automatic air release valves fitted at the lowest point of a central heating system to trap and release air build up in the system

b)

Automatic air release valves fitted at the highest point of a central heating system to trap and release air build up in the system

c)

Automatic siphon valves fitted at the high point of a central heating system to trap and release air build up in the system

d)

Drain off valve valves fitted at the lowest point of a central heating system to trap and release air build up in the system

3.

This component is called a:

a)

3 port actuator valves

b)

2 port actuator valves

c)

Automatic bi-pass valve

d)

Solenoid valve

4.

What is this photo indicating

a)

The paint is coming off the radiator

b)

The radiator is getting too hot

c)

Poor circulation due to a build up of iron-oxides

d)

Poor circulation due to a build up air

5.

What is this pipework component called

a)

Maxitee

b)

Manifold

c)

Bodge up

d)

Blending valve

6.

Which radiator has the highest output

a)
b)
c)
d)

You cant tell by looking, your need to consult the manufactures technical data

7.

What is the purpose of a Thermostatic valve on a radiator

a)

To control the temperature of the water in the radiator

b)

To turn off the radiator when the air temperature in the room is at the required level according to the setting on the valve head

c)

To turn off the radiator when the air temperature in the room is at the required level according to the room thermostat

d)

To turn on the radiator when the air temperature in the room is at the required level according to the setting on the valve head

8.

What type of boiler is this

a)

A system boiler

b)

A hot water only boiler

c)

Central heating only boiler

d)

A combination boiler

9.

What is the name of this central heating system component

a)

Feed and expansion tank

b)

Ventilation tank

c)

Feed and expansion cistern

d)

Cold water storage cistern

10.

What one of these components is NOT installed on a sealed heating system

a)
b)
c)
d)
11.

What is the name of this component

a)

Feed and expansion tank

b)

Pressure reservoir

c)

Expansion vessel

d)

Discharge valve

12.

Why are inhibitors added to a heating system

a)

To prevent iron oxide build ups

b)

To prevent the water from freezing

c)

To reduce noise in the system

d)

All the answers

e)

To prevent limescale build up in a boiler heat exchanger

13.

What is the name of this type of heating system

a)

Two pie

b)

Reversed return

c)

One pipe

d)

Secondary circulation

14.

Approximately how much heat is convected through the fins on the back of the radiators?

a)

100%

b)

85%

c)

50%

d)

25%

15.

Manufacturers recommend that depending on the height of the skirting, radiators should be fitted at least _____ from the floor.

a)

100mm

b)

150mm

c)

250mm

d)

400mm

16.

Which of the following is not a variation of connections for the radiator valves?

a)

TBOE

b)

BBOE

c)

TBSE

d)

TTOE

17.

Low surface temperature radiators are designed in order to keep the surface temperature low enough to not cause harm to any that touch. What temperature does it not exceed?

a)

75°C

b)

52°C

c)

43°C

d)

25°C

18.

Which of the following types of heat emitters potentially has blocked fins due to dust build-up?

a)

Skirting convector

b)

Fan convector

c)

Kickspace heater

d)

LST radiators

19.

The diagram shown can be identified as:

a)

Insulation plan

b)

Floor layout

c)

Underfloor heating system

d)

Trace heating system

20.

One radiator in the circuit must be left without a TRV fitted. Building Regulations state it should be the:

a)

Bathroom radiator

b)

Hallway radiator

c)

Front room radiator

d)

Kitchen radiator

21.

Which Building Regulation covers Central Heating

a)

part L

b)

part F

c)

Part J

d)

Part G

22.

Which type of boiler can meet the demand of both central heating & hot water

a)

Combination

b)

Heat only

c)

Regular

d)

System

23.

what does F&E stand for

a)

Float and expansion

b)

Feed and expansion

c)

Feed and evaluate

d)

Free and expansion

24.

what is an advantage to a one pipe system

a)

cheap to install

b)

looks nice

c)

doesn't require cleaning and maintenance

d)

each radiator progressively cools down

25.

what is the size of the primary pipework on a 2 pipe system incorporating a back boiler

a)

22mm

b)

28mm

c)

15mm

d)

54mm

26.

what is another name for a semi gravity two pipe system

a)

c plan

b)

s plan

c)

y plan

d)

f plan

27.

identify which components are needed to be added to the system to make a c plan a c plan plus

a)

zone valve

b)

cylinder stat

c)

TRV's

d)

Room stat

28.

Which system uses a 1 x 3 port Mid position valve

a)

Y plan

b)

S plan

c)

C plan

d)

F plan

29.

Which system uses 2 x 2 port zone valves

a)

S plan

b)

Y plan

c)

F plan

d)

C plan

30.

When a property has a floor area of over 150m2 it requires additional zoning. What type of system is this

a)

Y plan +

b)

S plan +

c)

C plan +

d)

F plan +

31.

On a three port mid position valve it is important to pipe up the correct port, which of the following is correct

a)

AB- flow from boiler

A- flow to heating circuit

B- flow to cylinder

b)

AB- flow to heating circuit
A- flow to cylinder
B- flow from boiler

c)

AB- flow to cylinder

A- flow to heating circuit

B- flow from boiler

32.

what is the purpose of central heating

a)

to provide thermal comfort

b)

keep you warm

c)

stop damp

d)

help indoor plants grow

33.

identify this system

a)

Y plan

b)

S plan

c)

C plan

d)

S plan +

34.

identify where this float operated valve would found in a heating system

a)

F&E tank

b)

CWSC

c)

Boiler

d)

Zone valve

35.

What should be done before working on any electrical component, including the boiler?

a)

Lock off the fuse holder ( safe isolation )

b)

Remove the fuse from the boiler

c)

Switch off the central heating system

d)

Switch off the boiler

36.

What is the purpose of balancing the system when the system is commissioned?

a)

To switch off the central heating system

b)

To remove hydrogen from the system

c)

To remove debris from the installation process

d)

To ensure uniform heating of radiators

37.

What is the recommended temperature difference between the flow and return pipework when the system is warm?

a)

10ºC

b)

9ºC

c)

8ºC

d)

11ºC

38.

What is the purpose of a hot flush in a central heating system?

a)

To remove debris from the installation process

b)

To remove hydrogen from the system

c)

To remove excess jointing compounds

d)

To remove excess flux residues and oils

39.

What is the purpose of a power flush in an older central heating system?

a)

To remove debris from the installation process

b)

To remove hydrogen from the system

c)

To remove excess jointing compounds

d)

To remove blockages in the system

40.

A heating system which relies completley on natural convection to work would be better known as......

a)

Semi gravity

b)

Fully pumped

c)

Full gravity

d)

C plan

41.

This type of system is known as a.........

a)

Fully pumped system

b)

Semi gravity system.

c)

Diverter valve system.

d)

Zone valve system.

42.

Building Regulations Approved Document L1A refers to what?

a)

Energy efficiency for new build properties

b)

Enegry efficiency in older properties.

c)

Energy efficiency for central heating systems.

d)

Energy efficiency in hot water systems.

43.

The 'bar' is used to measure what?

a)

Atmospheric pressure

b)

Water pressure

c)

System pressure

d)

Head of pressure

44.

The purpose of this is to ....

a)

Allow for the expansion of the system pipework

b)

Allow for the expansion of the water in the system

c)

Allow for the expansion of steam in the system

d)

Allow for the expansion of the air in the system

45.

The type of system a Honeywell 'S' plan is....

a)

3 port mid position valve

b)

3 port diverter valve

c)

2 x 2 port zone valves

d)

3 x 2 port zone valves

46.

A diverter valve system

a)

Gives central heating priority

b)

Gives hot water priority

c)

Gives heating and hot water the same priority

d)

Gives a mixture of central heating ans hot water priority

47.

A 'heat leak' radiator is used to .......

a)

Remove excess heat from the room.

b)

Allows more heat to come off the radiator.

c)

Remove excess heat from the system to prevent 'venting over'

d)

Remove excess heat from the system to prevent pipework from expanding too much.

48.

This type of fitting would be on a ......

a)

Small bore only system

b)

Small bore to microbore system

c)

Multi pipe system.

d)

One pipe system.

49.

How high should the open vent pipe on a central heating system extend?

a)

150mm above the water line

b)

250mm above the water line

c)

350mm above the water line

d)

450mm above the water line

50.

To calculate the height above the pump the F&E cistern should be installed we.....

a)

Divide the minimum head of the pump by 3

b)

Divide the medium head of the pump by 3

c)

Combine the minimum and maximum head of the pump and divide by 3

d)

Divide the maximum head of the pump by 3

51.

Yoou would find the neutral point in a system at....

a)

The boiler

b)

The last tee cylinder return at the boiler

c)

The pump

d)

Where the cold feed enters the central heating system

52.

The open vent and cold feed in a fully pumped system should not be installed further than........

a)

100mm apart

b)

125mm apart

c)

150mm apart

d)

175mm apart

53.

This fitting is called........

a)

Anti gravity valve

b)

Cytrol valve

c)

Air seperator

d)

Water seperator

54.

This type of heat emitter is known as......

a)

Towel rail

b)

Skirting heater

c)

Radiator

d)

Column radiator

55.

The valve is

a)

Anti gravity valve

b)

Cytrol vale

c)

2 Port valve

d)

Auto bypass valve

56.

This condition shown is known as

a)

Steaming

b)

Venting

c)

Pluming

d)

Cooling

57.

An F&E cistern need to comply with Byelaw 30

a)

True

b)

False

58.

The purpose of fitting a bypass valve is to

a)

Allow water to circulate through the radiators after the motorized valve has closed.

b)

Allow water to circulate between the flow and return from the boiler after the motorized valve has closed.

c)

Allow water to circulate through the cylinder after the motorized valve has closed.

d)

Allow water to circulate through the boiler to balance the system.

59.

Which of these is the correct order for the 3 Tee rule

a)

cold feed, open vent, cylinder return

b)

Cylinder return, cold feed, open vent

c)

open vent, cold feed, cylinder return

d)

open vent, cylinder return, cold feed

60.

The water in a central heating system will expand by...........

a)

14%

b)

Not at all

c)

10%

d)

4%

61.

The type of flue shown in the picture is known as..

a)

Natural draught

b)

Conventional flue

c)

Fan assisted flue

d)

Natural draught balanced flue

62.

The deposit on the inside of the pipe shown is..........

a)

Black sludge

b)

Iron oxide

c)

The black gunge

d)

Copper oxide

63.

This device is to......

a)

Control the temperature of hot water

b)

Control the temperature of central heating

c)

To stop the system from freezing

d)

Control the temperature of the boiler

64.

The name given to the series of controls which shuts down the system completely is .........

a)

System control locking

b)

Boiler control lock

c)

Boiler interlock

d)

Interlocking boiler

65.

What is the measurement of the U-value?

a)

w/m²K

b)

kj/m°C

c)

w/kg/K

d)

J/m³/K

66.

What are the likely effects of oversizing a heating system?

a)

Reduced energy usage, as systems produce enough heat quickly before shutting off for longer periods

b)

Reduced life expectancy of heat emitters, which often overheat due to higher temperatures

c)

Greater risk of burns/scalds, due to excess temperatures within the system and increased boiler combustion efficiency

d)

Reduced energy efficiency, as boilers ‘hunt’, and greater initial outlay costs

67.

What is the most suitable external design temperature for a house with normal sheltered exposure in England and Wales?

a)

-1°C

b)

-3°C

c)

-4°C

d)

-5°C

68.

What is the correct formula to determine the heat loss through a surface such as a wall or window?

a)

m² x Δt x 1.33

b)

m² x Δt x U-value

c)

m³ x QTY x Δt 0.33

d)

m³ x U-value x QTY x 3

69.

What is the term given to the radiator within a central heating system which is the furthest from the heat source?

a)

The content circuit

b)

The shunt circuit

c)

The hydraulic circuit

d)

The index circuit

70.

What is the purpose of a hot flush of the central heating system?

a)

To remove excess limescale deposits from the system

b)

To ensure that the system flow rates can be achieved throughout the installation

c)

To remove traces of the legionella bacteria from the system pipework

d)

To remove excess jointing compounds, fluxes and oils from the system

71.

A radiator has stopped working and is completely cold. All the other radiators in the system are hot and no air is present in the cold radiator. What is the most likely problem?

a)

Pin stuck within TRV

b)

Sludge blocking parts of the radiator

c)

Faulty pump

d)

System needs balancing