wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Electrical Installation and Maintenance Quiz

Total questions: 59

Worksheet time: 2hrs 47mins

Name
Class
Date
1.

PART OF AUXILLIARY DEVICE OF CCTV THAT MONITOR MOTION ONLY- CAMERA

4 lines
2.

COMMONLY USED TYPE OF CONDUIT IN SERVICE ENTRANCE

a)

RSC-RIGID STEEL CONDUIT

b)

IMC-INTERMEDIATE METALLIC CONDUIT

3.

DIAGRAM THAT SHOWS THE LOCATION AND ACTUAL TERMINATION OF THE AUXILLIARY DEVICES - WIRING DIAGRAM

4 lines
4.

GROUND HAS A LOWER RESISTANCE COMPARED TO THE BODY. SINCE CURRENT TENDS TO FLOW TO LOWER RESISTANCE, IF THERE IS A GROUNDING SYSTEM IT WILL PREVENT ELECTRIC SHOCK

4 lines
5.

CLASSIFICATION OF CURRENT

a)

DIRECT CURRENT-ONE DIRECTION

b)

ALTERNATING CURRENT-REVERSES A NUMBER OF TIME/SECOND

6.

TYPES OF CIRCUIT

a)

SERIES CIRCUIT

b)

PARALLEL CIRCUIT

c)

SERIES PARALLEL CIRCUIT

7.

FDAS - FIRE DETECTION ALARM SYSTEM COMPONENT:

4 lines
8.

CCTV - CLOSE CIRCUIT TELEVISION COMPONENTS:

4 lines
9.

HEIGHT OF SWITCHES

a)

MAXIMUM-1500mm

b)

MINIMUM – 1400 mm

10.

HEIGHT OF CONVENIENCE OUTLET

(a)  

11.

Panel Board

a)

180 CM – MINIMUM

b)

195 CM - MAXIMUM

12.

DIFFERENT TYPES OF CONDUIT

a)

METALLIC (RMC, IMC, EMT, FMC)

b)

NON METALLIC (PVC)

c)

NON-METALLIC FLEXIBLE CONDUIT

13.

PURPOSE OF PROVIDING TOOLBOX AND GUTTER

a)

CABLE PULLING AND SPLICING

b)

TERMINATING WIRE

14.

PURPOSE OF ELECTRICAL KNIFE INSTEAD OF PLIER

4 lines
15.

PPE-PERSONAL PROTECTIVE EQUIPMENT (FOR PERSONAL SAFEGUARDING)

a)

HARDHAT

b)

GLOVES

c)

SAFETY SHOES

d)

GOOGLES

16.

HOW TO PROTECT ELECTRICAL SYSTEM

a)

INSTALL TRANSIENT VOLTAGE SURGE SUPPRESSOR

b)

LIGHTNING ARRESTER

17.

OTHER TERM FOR VOLTAGE

4 lines
18.

WHAT WILL YOU DO IF THE INSTALLATION MANUAL FOR INSTALLING SELECTOR SWITCH IS NOT AVAILABLE

4 lines
19.

WHAT DO YOU MEAN BY ENCLOSURE

4 lines
20.

WHAT ARE THE TYPES OF SERVICES APPLIED IN A BUILDING

a)

SERVICE DROP CONDUCTOR FROM ELECTRICAL POLE TO RESIDENTIAL HOUSES

b)

SERVICE ENTRANCE CONDUCTOR

c)

SERVICE EQUIPMENT

21.

PEC

4 lines
22.

TECHNICAL TERM FOR THE TYPE THW WIRES

4 lines
23.

AMPACITY OF NO. 8.0 S.Q. MM THW WIRE

(a)  

24.

WHAT IS THE MAXIMUM LOAD OF 5.5 S.Q.MM TW WIRE INSIDE A CONDUIT PIPE WITH 80% LOADING?

(a)  

25.

AMOUNT OF CURRENT DRAWN BY INCANDESCENT BULB CONNECTED TO A 115V AND 264.5 OHMS

(a)  

26.

THE SIZE OF CIRCUIT BREAKER FOR 40A MOTOR FULL LOAD CURRENT

4 lines
27.

KAIC

4 lines
28.

AF-AMPERE FRAME

4 lines
29.

AT-AMPERE TRIP

4 lines
30.

TYPE OF FITTING USED FOR TIGHTENING BETWEEN THE BOXES AND RSC CONDUIT

4 lines
31.

BOX USED FOR CONVENIENCE OUTLET AND TYPICAL SWITCH

(a)  

32.

MINIMUM SIZE OF CONDUIT COMMONLY USED IN LAYING OUT OF AUXILLIARY DEVICES

4 lines
33.

KIND OF FITTING RESEMBLING A PIPE WITH A REMOVABLE COVER ACCESS TO CONDUIT

(a)  

34.

LOCKNUT, BUSHING AND CONNECTORS ARE EXAMPLES OF

(a)  

35.

DIAGRAM THAT IS USED IN DESIGNING OR TROUBLE SHOOTING ELECTRICAL INSTALLATION CONTROL EQUIPMENT ARRANGED TO FACILITATE THE TRACING OF THE CIRCUIT

4 lines
36.

AN ACCESSORY WHICH SERVES TO COMPLETE A CONDUIT SYSTEM, SUCH AS BUSHING AND ACCESS FITTINGS

(a)  

37.

THESE ARE SHEET METAL THROUGHS WITH HINGED OR REMOVABLE COVERS FOR HOUSING AND PROTECTING ELECTRICAL WIRES AND CABLES AND IN WHICH CONDUCTOR ARE LAID IN PLACE

(a)  

38.

MAJOR PART OF DOOR ACCESS

a)

MAGNETIC LOCK

b)

POWER SUPPLY

c)

BIOMETRIC READER AND CONTROLLER

d)

EMERGENCY BUTTON

e)

ACCESS CARD

39.

WHAT IS THE FUNCTION OF MOTION DETECTION IN CCTV?

4 lines
40.

WHAT IS A WIRING DIAGRAM IN AUXILLIARY DEVICE SYSTEM?

a)

A DIAGRAM THAT SHOWS THE LOCATION AND ACTUAL TERMINATION OF THE AUXILLIARY DEVICE

b)

IT HELPS TO UNDERSTAND THE WIRING CONNECTION OF AUXILLIARY DEVICE

41.

NAME AT LEAST 3 TYPES OF PROTECTIVE DEVICE TO BE WORN ON MOST JOB SITES

a)

HARDHAT

b)

SAFETY GLOVES

c)

GOGGLES

d)

SAFETY SHOES

e)

APRON

42.

IN STANDARD PRACTICE, WHY IS RUBBER TAPE COMMONLY USED IN INSULATING BARE CONDUCTOR ESPECIALLY IN OUTDOOR INSTALLATIONS?

4 lines
43.

AS A SAFETY MEASURE, WHY IT IS NOT ADVISABLE TO USE WATER IN EXTINGUISHING FIRE?

4 lines
44.

WHAT IS THE BEST MOVE IN USING POWER TOOLS IN AN INSTALLATION?

4 lines
45.

GIVE AT LEAST 5 EXAMPLE OF FITTING USE IN INSTALLATION

a)

LOCKNUT

b)

BUSHING

c)

STRAIGHT CONNECTOR

d)

CONDULET

e)

COUPLING

46.

WHAT ARE THE 2 TYPES OF SERVICE ENTRANCE?

a)

OVERHEAD SERVICE ENTRANCE

b)

UNDERGROUND SERVICE ENTRANCE

47.

WHAT ARE THE 2 TYPES OF TRANSFORMER

a)

STEP UP TRANSFORMER

b)

STEP DOWN TRANSFORMER

48.

AN ELECTRICIAN SHOULD ALWAYS HAVE HIS TOOLS IN GOOD WORKING CONDITION THE MOST IMPORTANT REASON IS BEING IS

4 lines
49.

WHAT TYPE OF HAND TOOL IS COMMONLY USE IN BORING OF 1⁄2" DIAMETER HOLE IN A PANEL BOARD

(a)  

50.

WHICH OF THE FOLLOWING PARAMETERS APPLY OR LABELED TO ALL KIND OF SWITCHES

4 lines
51.

CIRCUIT BREAKER IS AN ELECTRICAL PROTECTIVE DEVICE WHICH

4 lines
52.

WHEN MEASURING LOAD RESISTANCE THE OHMETER IS CONNECTED

4 lines
53.

FACP MEANS

4 lines
54.

WHAT IS 5S ?

4 lines
55.

Commonly used adhesive materials for joining PVC conduits

(a)  

56.

The size of circuit breaker to be used in 40 AMFS, motor full load

(a)  

57.

A live duplex wire can be de-energized quickly and safety by outing

4 lines
58.

When measuring load current on ammeter is connected

4 lines
59.

When measuring load resistance, the ohmmeter is connected

4 lines