Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Quiz 1 [Part 2]

Total questions: 24

Worksheet time: 12mins

Name
Class
Date
1.

What is the required setback from the rear property line for residential buildings?

a)

1 meter

b)

2 meters

c)

3 meters

d)

5 meters

2.

For commercial buildings in urban areas, the side setback requirement is typically:

a)

1 meter

b)

2 meters

c)

None, if adjacent to another building

d)

3 meters

3.

What is the minimum fire-resistance rating for walls between two units in a residential condominium?

a)

1 hour

b)

2 hours

c)

3 hours

d)

4 hours

4.

Smoke detectors are mandatory in which of the following areas?

a)

Hallways in residential buildings

b)

Bedrooms in hotels

c)

Storage areas in commercial buildings

d)

All of the above

5.

Automatic sprinkler systems are required in buildings with a floor area greater than:

a)

500 sqm

b)

1,000 sqm

c)

1,500 sqm

d)

2,000 sqm

6.

Sprinkler systems must be designed to cover all areas of a building except:

a)

Bathrooms less than 5 sqm

b)

Electrical rooms

c)

Attics without combustible material

d)

All of the above

7.

The minimum width of a residential bathroom as per NBCP is:

a)

0.80 meters

b)

1.00 meter

c)

1.20 meters

d)

1.50 meters

8.

What is the minimum floor area for a kitchen in a residential house as per NBCP?

a)

3.00 sqm

b)

3.50 sqm

c)

4.00 sqm

d)

None of the above

9.

The counter height for a kitchen worktop in residential buildings should typically be:

a)

0.80 meters

b)

0.85 meters

c)

0.90 meters

d)

1.00 meter

10.

The minimum ceiling height for a kitchen is the same as which of the following areas?

a)

Bathroom

b)

Bedroom

c)

Living room

d)

None of the above

11.

What is the minimum width of an egress door for buildings as per the NBCP Fire Code?

a)

0.70 meters

b)

0.80 meters

c)

0.90 meters

d)

1.00 meter

12.

In residential buildings, a fire escape ladder is required for buildings more than:

a)

3 stories

b)

4 stories

c)

5 stories

d)

6 stories

13.

Smoke detectors in residential buildings must be located at a minimum distance of:

a)

1 meter from kitchen appliances

b)

2 meters from air vents

c)

3 meters from cooking equipment

d)

5 meters from windows

14.

The spacing of sprinkler heads in office buildings should not exceed:

a)

3 meters

b)

4 meters

c)

5 meters

d)

6 meters

15.

What is the minimum floor area of a bathroom for a residential house as per the National Building Code?

a)

1.00 sqm

b)

1.20 sqm

c)

1.50 sqm

d)

2.00 sqm

16.

Which of the following must be included in the design of a bathroom for a residential house?

a)

Proper ventilation or exhaust fans

b)

Anti-slip flooring

c)

Adequate drainage

d)

All of the above

17.

What is the recommended minimum width of a residential kitchen?

a)

1.20 meters

b)

1.50 meters

c)

1.80 meters

d)

2.00 meters

18.

Which of the following is NOT a requirement for a kitchen in residential buildings?

a)

Presence of a fire extinguisher or fire blanket

b)

Adequate counter space for food preparation

c)

Windows for natural lighting and ventilation

d)

A sink with hot and cold water supply

19.

Kitchen ventilation should ensure proper removal of:

a)

Cooking odors

b)

Excess moisture

c)

Combustion gases

d)

All of the above

20.

The minimum setback for a school building's frontage is:

a)

3 meters

b)

5 meters

c)

7 meters

d)

10 meters

21.

What is the primary purpose of fore resistance ratings in building construction?

a)

Enhance energy efficiency

b)

Prevent water intrusion

c)

Delay the spreed of fire for a specified time

d)

Improve building aesthetic

22.

In case the water suply for the sprinkler system is exhausted, how is water supplied to the building in a dry-pipe system?

a)

Water is automatically replenished from underground reserves

b)

Water is supplied from the fireman's hoses or external hydrants through stand pipe system

c)

The building'd water tank is activated to suply water in the sprinklers

d)

The water supply from the building'd plumbing system is rerouted to the splinkers system

23.

Why are standpipes an essential part of a dry-pipe fire protection system?

a)

They provide a direct connection to the sprinkler system

b)

They allow firefighters to quickly access water from external hydrantsand fire hoses to fires

c)

They hold pressurized air until needed for firesprinkler activation

d)

They store water for future firefighting needs

24.

What triggers an automatic sprinkler system to activate?

a)

A smoke detection in the room

b)

A manual switch pressed by occupants

c)

Heat from the fire causing a glass bulb or a fusible link to break

d)

Movement detected near the sprinkler