Routine Test / ITO

Total questions: 10

Worksheet time: 5mins

Name
Class
Date
1.

During a quality control inspection at a manufacturing plant, SAKSHI is tasked with verifying the specifications of the products. She needs to determine which clause is applicable for "Sheet Thickness Checking".

a)

11.1

b)

11.2

c)

11.3

d)

11.4

2.

While working on a science project, RAM needs to find out the potential difference between two points in his circuit. He wonders, what is the device called that he should use to measure this potential difference?

a)

Voltmeter

b)

Ammeter

c)

Altimeter

d)

Speedometer

3.

SNEHA is working on a science project where she needs to power a small circuit. She wonders, _____ is a device that helps to maintain a potential difference across a conductor.

a)

Voltmeter

b)

Ammeter

c)

Key

d)

Battery

4.

TARA is working on a science project about electricity. She learns that the relationship between voltage (V), current (I), and resistance (R) can be expressed with the formula V = IR. This formula is also known as the

a)

Ampere's Law

b)

Ohm's Law

c)

Electrical Law

5.

During a routine inspection at a manufacturing facility, Aisha is tasked with assessing the LV switchboards. What is the primary purpose of routine testing of LV switchboards?

a)

To evaluate software compatibility

b)

To verify design parameters

c)

To ensure each unit complies with standards before dispatch

d)

To compare with competitor’s product

6.

Which of the following is NOT typically a part of routine tests for LV switchboards?

a)

Verification of dielectric properties

b)

Temperature rise test

c)

Continuity of protective circuits

d)

Verification of degree of protection (IP)

7.

Dielectric test in LV switchboards is conducted to check:

a)

The strength of enclosure materials

b)

Resistance to heat

c)

Insulation between live parts and earth

d)

The torque of mechanical fasteners

8.

During a routine maintenance check at a local electrical facility, the technician needs to perform a dielectric test on the LV switchboards that are rated for 690V. What is the standard test voltage that should be used for this dielectric test?

a)

500V

b)

1000V

c)

2500V

d)

5000V

9.

Visual inspection in routine testing helps identify:

a)

Voltage harmonics

b)

Earthing resistance

c)

Incorrect wiring, missing components, and workmanship issues

d)

Panel weight

10.

According to IEC 61439-1, which test ensures protective measures against electric shock are effective?

a)

Temperature rise test

b)

IP test

c)

Verification of dielectric properties

d)

Verification of protection against electric shock