Installed at the bottom portion of the soil stack where the house drain is connected to receive the discharge from aerator?
Aerator
Deaerator
Sovent system
Single stack system
Used as a terminal of the soil branch in each floor?
Aerator
Deareator
Sovent system
Single stack system
Always located near the stairs for use by firemen in case of fire?
Standpipe
Hydro pneumatic pump
Fire hose
Fire tank
It considers the building density in the locality and flammability of the structures and its content.
Civil code
Fire protection code
Fire code
Fire suppression code
A vertical pipe usually used for the storage of water frequently under pressure.
Vent pipe
Vertical pipe
Stand pipe
Waste pipe
Minimum of number of water closet required at Office 20 persons for employee use?
1
2
3
4
Minimum of number of water closet required at elementary school for 35 females?
1
2
3
4
When a backflow prevention device does not bear a critical level marking, the part of the device that shall constitute the critical level is the ____.
Top
Bottom
Center
Outlet invert
Disposal of sewage, or other liquid waste shall be by means of ____.
Chemical toilets
Sewage retaining tanks
Drainage system of the building
Subsurface leaching pits
Roofs, inner courts, vent shafts, light wells or similar areas having drains shall discharge to (a) ____.
Sanitary sewage system
Private sewage disposal system
Sump with pump discharge into the house drain
Outside of the building or gutter
The organization, office, or individual responsible for enforcing the requirements of a code or standard is the ____.
Administrative authority
Building department
Plumbing inspector
Authority having jurisdiction
A mechanical device used to circulate hot water to the plumbing system?
Overhead feed
Upfeed
Pump circuit
Hot water
Used on a smaller distribution system 6 m or less for elevating water wells or other sources.
Piston pump
Centrifugal pump
Water pump
Pumping station
It is inserted into the water main and it serves as the control of the water service.
Curb stop
Corporation stop
Water stop
Meter stop
Piping, fixtures or equipment that are installed so that they interfere with normal operation and use of windows or doors shall be ____.
Protected from damage
Identified for restricted use
Relocate to avoid interference
Approved if acceptable by the owner
The valve for controlling two or more outlet in a cold water supply line may be a?
Heavy duty gate valve
Full way gate valve
Ground key valve
Non-rising stem globe valve
Refers to the pressure range measured over a period of 24 hours.
Static pressure
Residual pressure
Normal pressure
Critical pressure
Air pressure in drainage pipes greater than atmospheric pressure.
Normal pressure
Standard pressure
Back pressure
Self-siphonage
Refers to an individual who worked in the sanitary field of ancient Rome.
Plumbum
Plumber
Plumbarius
Plumbob
It shall be the minimum cross-sectional area at the seat of the control valve or the supply pipe or tubing which feeds the device or outlet.
Window opening
Roof drain
Effective opening
Airgap
Airgap less than 25 mm shall only be approved as a permanent part of a listed assembly that has been tested under actual backflow conditions with vacuums of from?
0 to 63.5 cm of mercury
0 to 65.3 cm of mercury
5 to 63.5 cm of mercury
5 to 65.3 cm of mercury
Upright position, has a minimum of 150 mm or listed distance above all downstream piping and flood level rim of receptor as a function of device assembly.
Atmospheric vacuum breaker
Double check valve backflow preventer (DC)
Reduced Pressure Principle Backflow Preventer (RP)
Spill Proof Pressure Type Vacuum Breaker
As a function, it requires 30.5 cm minimum clearance at bottom for maintenance. May need platform/ladder for test and repair. May discharge water.
Atmospheric vacuum breaker
Double check valve backflow preventer (DC)
Reduced Pressure Principle Backflow Preventer (RP)
Spill Proof Pressure Type Vacuum Breaker
As a function it requires 30.5 cm minimum clearance at bottom for maintenance. May need platform/ladder for test and repair. Does not discharge water.
Atmospheric vacuum breaker
Double check valve backflow preventer (DC)
Reduced Pressure Principle Backflow Preventer (RP)
Spill Proof Pressure Type Vacuum Breaker
A general requirement, where access and clearance shall require minimum of ____ space between the lowest portion of the assembly and the grade, floor or platform.
300 mm
305 mm
310 mm
320 mm
An approved atmospheric vacuum breaker is installed not less than ____ above the flood level rim of such trapped fixture, so that at no time will any such device be subjected to any backpressure.
125 mm
152 mm
205 mm
305 mm
Water closet and urinal tanks shall be equipped with a listed ball cock shall be installed with the critical level at least ____ above the full opening of the overflow pipe.
20 mm
25 mm
32 mm
38 mm
Water closet flushometer tanks shall be protected against backflow by an approved ____ device or method.
Backflow prevention assembly
P-trap
Water seal
Backwater valve
Water supply inlets not protected by atmospheric vacuum breakers shall be protected by approved.
Airgap
Shock arrester
Safety valve
Ball cock
Potable water outlet with hose attachments other than water heater drains and clothes washer connections shall be protected by a listed or by a listed atmospheric vacuum breaker.
Non-removable hosebibb-type backflow preventer
Removable hosebibb-type backflow preventer
General hosebibb-type backflow preventer
Updated hosebibb-type backflow preventer
A device that shall not be located in any area containing fumes that are toxic, poisonous and corrosive.
Backflow preventer
Backwater valve
Back-siphonage
Backflow connection
Where a grounding system, acceptable to the AA is installed, inspected and approved metallic pipe may be replaced with?
Non-ferrous pipe
Non-metallic pipe
Fittings and adaptor
Standard pipe
Elevated or gravity tank vent shall be screened with a fine corrosion-resistant screen with openings not less than.
14-18 mess per 25 mm
14-18 mess per 32 mm
10-15 mess per 25 mm
10-15 mess per 32 mm
In water distribution system, it shall be installed on the water heating system in an approved location based on its listing requirements and the manufacturer’s instructions.
CT & PRV
DC & PRV
RP & CT
PRV & RP
In water piping, it shall provide equivalent protection and application is restricted to those short pipe lengths at point of connection with fittings necessarily stripped fro threading and jointing.
Field bitumastic coating and wrapping
Appoved gout coating
Rubber insulation
Red oxide paint
Unions shall be installed in the water supply piping within away from regulating equipment, water heater, conditioning tank and similar equipment.
½ ft
1 ft
2 ft
3 ft
No water filter, water softener, backflow prevention device or similar devices regulated by this Code shall be installed in any potable water supply piping when the diameter of the inlet and/or outlet of nay device or its connecting pipings are less than the diameter of the water supply distribution piping.
True
False
Maybe
Trulse
In water piping, it shall not compress, distort cut or abrade the piping and shall allow free movement of pipe.
Hangers & straps
Hanger rod and angle bar
Water pipe
Thrust blocking
It shall be tightly fastened with corrosive resistant fasteners up to the floor with top surface ¼ inch (6.4 mm) above finish floor.
Neoprene gaskets
Closet rings
Closet flange
Teflon tape
It shall be installed at all changes in direction as tees and bends, change in size as reducers, stops as a dead ends and valves.
Fittings
Hangers & Supports
Thrust blocking
Cleanouts
The result estimating continuous supply demands in LPS for lawn sprinklers, air conditioners, etc, and add the sum to the total demand for fixtures.
Estimated supply demands
Estimated peak load demand
Permissible friction loss
Pressure losses
In WSFU, the weights for maximum separate demands may be taken as of the listed demand for the supply.
50%
75%
80%
100%
In sizing water supply system, velocities shall not exceed of the maximum values given in the appropriate installation standard.
5 m/s
3 m/s
8 m/s
1 m/s
Hot water piping system over shall be provided with backflow preventer designed to operate without rendering any portion of the assembly inoperative.
110⁰F
120⁰F
105⁰F
130⁰F
PEX tubing shall be installed not less than from the water heater.
16”
18”
20”
24”
A pipe installed to vent, a fixture trap and which connects with the vent system above the fixture served or terminates in the open air.
Individual vent
Stack vent
Loop and circuit vent
Relief vent
Trap size of fixtures for Wash basin.
1 ¼”
1”
2 ¼”
2”
Trap size of fixtures for slop sinks (ordinary).
2”
3”
1”
4”
Minimum cost. Least efficient subject to clogging, noisy. Simple washout and emptying through small irregular passage way, prohibited by some health codes.
Wash down
Reverse trap
Blow out
Bidet
Trap size of fixtures for Urinals (through).
1”
2”
2 ¼”
1 ½”
Includes water supply and distribution pipe; plumbing fixture and traps, soil, waste and vent pipes; house drain and house sewers including their respective connections.
Water reservoir
Siamese connections
Plumbing system
Trap seal
Trap size of fixtures for Water closets.
4”
6”
2”
3”
Ratio of water closets for female population for elementary and secondary school.
Ratio of 1:45
Ratio of 1:25
Ratio of 1:55
Ratio of 1:30
A valve which in the water flow is shut off by a flat disk that is screwed down onto its seat.
Compression valve
Overhead storm drain
Pressure reducing valve
Union patente
The luminous flux density incident on a surface.
Illumination
Flood level
Plumbing system
Fixture branch
A short length of pipe with threads at each end; used to join couplings or fittings.
Dead End
Nipple
Fixture Branch
Thimble
Trap size of fixtures for Sinks (Dishwashers).
1”
1 ½”
1 ¼”
½”
A pipe connecting upward from a soil and waste stack to a vent stack for the purpose of preventing pressure changes in the stack.
Yoke vent
Wet vent
Dry vent
Local vent
Trap size of fixtures for Drinking Fountain.
½”
1 ¼”
¼”
1”
A trench containing course aggregate and a distribution tile pipe through which septic tank effluent may flow covered with earth.
Absorption trench
Illumination
Air trap
Catch basin
Trap size of fixtures for Combination Fixture.
1”
1 ½”
¼”
½”
Color coding of high pressure steam.
Black
White
Blue
Green
A passage under a road, embankment or canal which allow for the flow of water.
Cistern
Culvert
Catch basin
Air trap
Is the backflow of used, contaminated or polluted water from a plumbing fixture due to negative pressure.
Backflow
Back siphonage
Yoke vent
Friction loss
Is the lowest portion of the inside of any pipe or conduit that is not vertical.
Invert
Fixture branch
Soil pipe
Rough-in
An underground structure for drainage into which water from the roof or floor will drain through sewer.
Cistern
Corporation stop
Absorption trench
Catch basin
An underground tank reservoir to store water.
Catch basin
Corporation stop
Cistern
Absorption trench
Ratio of water closets for female population for principal worship places.
Ratio of 1:75
Ratio of 1:60
Ratio of 1:85
Ratio of 1:70
Noisy but highly efficient. Strong jet into leg forces contents out. Higher pressure required.
Bidet
Reverse trap
Siphon-jet
Blow out
A U-shaped pipe filled with water and located beneath the plumbing fixtures to form a seal against the passages of gases and odors.
Air trap
Wash down
Bidet
Siphon-jet
Trap size of fixtures for Fountain cupsiders.
1 ½”
1 ¼”
1’
½”
Fitting for base or soil stack and building drain.
½” bend
1 ¼” bend
1 ½” bend
¼” bend
The length along the center of the pipe and fitting.
Fixture branch
Soil pipe
Developed length
Invert
Trap size of fixtures for Floor drain.
2”
2 ½”
4”
3”
Moderately noisy. Similar to siphon jet except that rap passageway and water surface area are smaller.
Wash down
Reverse trap
Bidet
Blow out
Trap size of fixtures for Laundry trays.
1”
1 ¼”
1 ½”
2”
It is permitted that a branch soil or waste pipe to which two and more than 8 water closets, pedestal urinals, trap standard slop sinks, or shower stall are connected in a series.
Relief vent
Unit vent
Local vent
Loop or circuit vent
A short internally-threaded (female thread) section of pipe, used to join two pipes of conduits.
Coupling
Invert
Nipple
Union
A vent connecting at the junction of two fixture drains and serving as a vent for both fixtures a single vent that ventilates multiple raps, in the case of back to back fixture.
Branch vent
Common vent
Continuous vent
Dry vent
The third kind of water after the storm water and area water.
Green water
Black water
Blue water
Gray water
Quiet, extremely sanitary. Like the siphon jet but having the flushing water directed through the rim to create a vortex that scours the bowl.
Siphon-jet
Siphon vortex
Siphon sat
Siphonage
Piping which shall not be installed under or within 2 ft (0.6m) at any building or structure is?
Cast iron
Plastic
Copper
Asbestos cement
The extension of a soil or waste stack above the highest horizontal drain connected to the stack horizontal drain, the uppermost end above the roof.
Yoke vent
Stack vent
Individual vent
Loop or circuit vent
A branch vent that serves two or more traps and extends from in front of the last fixture connection of a horizontal branch to the vent stack.
Branch vent
Continuous vent
Circuit vent
Common vent
Ratio of water closets for male population for elementary and secondary school.
Ratio of 1:20
Ratio of 1:40
Ratio of 1:30
Ratio of 1:35
A pipe fitting within the interconnection of pipes for the purpose of easy dismantling of the connection when needed.
Water reservoir
Absorption trench
Caulking
Union patente
Service drop conductor clearance over the roof.
2.0 m
3.0 m
3.5 m
2.5 m
A device that discharge a predetermined volume of water to fixture for flushing purposes and is activated by direct water pressure.
Urinals
Flushometer valve
Illumination
Siphon jet
Trap size of fixtures for Bathfoot.
1 ¼”
1”
1 ½”
2”
The principal artery of the venting system to which vent branches maybe connected.
Main vent
Unit vent
Yoke vent
Relief vent
Wet standpipe for a riser not more than 15 m.
2”
1”
4”
3”
A flange that closes the end of a pipe used to discharge water.
Black flange
Blank flange
Blind flange
Flat flange
Minimum height of dry standpipe outlet from the floor line.
60 mm
61 mm
53 mm
50 mm
Trap size of fixtures for urinals (up).
1”
½”
1 ¼”
1 ½”
A branch vents that performs its functions for two or more traps.
Main vent
Unit vent
Continuous vent
Group vent
Trap size of fixtures for Sinks (kitchen or residence).
2”
¼”
1”
1 ½”
A horizontal vent connecting one or more individual vents with a vent stack and stack vent.
Continuous vent
Common vent
Branch vent
Circuit vent
Minimum height of Fire Service Connection from the grade/floor.
36 mm
35 mm
45 mm
46 mm
Refers to any group of two or more similar adjacent fixtures which discharge into a common horizontal waste or soil branch.
Bathroom group
Fixtures group
Soil pipe group
Battery of fixtures
Is a pipe connecting several fixtures.
Overhead storm drain
Sewage pipe
Branch vent
Fixture branch
A valve which maintains uniform pressure on its outlet side regardless of its pressure fluctuation on the inlet side above the pressure level.
Pressure relief valve
Pressure loss valve
Friction loss valve
Pressure reducing valve
Used to connect the two ends pipes, neither of which can be turned.
Ferrule
Plug
Oakum
Union
Ratio of lavatory to number of occupants.
Ratio of 1:4
Ratio of 1:3
Ratio of 1:5
Ratio of 1:2
Maximum height of Fire Service Connection from grade/floor.
122 mm
130 mm
125 mm
118 mm
A flange that is not drilled.
Blind flange
Blank flange
Flat flange
Double flange
The type of bathtub other than sunken, square, free standing.
Corner
Inside
Embedded
Recessed
A type of fitting for yoke vent.
Wye fitting
Long sweep
Tee fitting
¼ bend
Another classification of storm drain, besides from inside drain and outside drain.
Catch basin
Underhead storm drain
Overhead storm drain
Culvert
Is a device located at the bottom of the tank for the purpose of flushing water closets and similar fixtures.
Flush valve
Flushometer valve
Ball valve
Float valve
Is the extended portion of a pipe that is closed at one end to which no connections are made on the extended portion.
Cleanout
Dead end
Blind flange
Blank flange
Install to be able to meet the water requirements during peak demands from a low yielding water well.
Artesian well
Flowing well
Water reservoir
Septic tank
Process of flushing, cleaning to remove dirt by the flowing liquid through it.
Scouring
Cleaning
Draining
Scrubbing
Ratio of urinals for elementary schools.
Ratio of 1:70
Ratio of 1:75
Ratio of 1:65
Ratio of 1:85
Trap size of fixtures for Urinal (stall).
2 ½”
3”
1 ½”
2”
Trap size of fixtures for slop sinks (with combine trap).
2”
1 ½”
2 ½”
3”
Trap size of fixtures for Urinals (pedestal).
2”
3”
4”
1 ½”
An arrangement of venting so installed that one vent pipe will serve two traps.
Unit vent
Yoke vent
Stack vent
Local vent
Trap size of fixtures for pantry or bar.
1 ½”
1 ¼”
1”
2”
A vent that does not serve as drain and is located where it is not exposed to back up of waste from a drainage pipe.
Wet vent
Dry vent
Branch vent
Local vent
Color coding for fuel oil division.
White
Green
Blue
Black
Trap size of fixtures for bath Shower stall.
2 ¼”
2”
3”
2 ½”
Trap size of fixtures for Bidet.
1 ½”
¼”
½”
1”
Minimum discharge pipe and fitting for bathtub.
1 ¼”
2 ½”
1 ½”
2”
Wet standpipe for riser more than 15 m.
2”
4”
2 ½”
3”
Sanitary, efficient very quiet. A toilet bowl which the flushing water enters through the rim and siphonic action initiated by a water jet draws the contents of the bowl through the trap way.
Siphon vortex
Siphon jet
Siphonage
Siphon wash
Dry standpipe for a riser below 23 m.
2”
3”
6”
4”
It is a pipe on the fixture side of the trap through which vapor or foul air is removed from a room fixture.
Wet vent
Dry vent
Main vent
Local vent
Tap used to measure pressure in a water system.
Pressure reducing valve
Pressure cock
Compression valve
Pressure relief valve
The lowest portion of the inside top surface of the channel through trap.
Crown weirs
Dip
Tip
Invert
Water which undergoes treatment, either physical, biological or chemical means to improve water quality.
Distilled water
Purified water
Fresh water
Mineral water
A bathroom containing a water closet and a lavatory.
Full bath
Half bath
Enclosed shower room
toilet
How many gallons of water for the water closet flushing requirements?
30 gallons
0.75 – 2 gallons
3-5 gallons
2-2.5 gallons
Flushing is very noisy, expensive and has a low water usage (1.5 gpf) that helps conserve water. Large water surface makes this model efficient and design features make it suitable for residential use.
Pressure tank
Siphon vortex
Siphon jet
Wash down
A vent connecting at the junction of two fixture drains and serving as a vent for both fixtures.
Branch vent
Continuous vent
Circuit vent
Common vent
How can you differentiate between soil pipe and waste pipe when laid side by side.
Color
Smell
Diameter
Taste
It is added to water to reduce salinity.
Chlorine
Electrolysis
Purifier
Clarifier