wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

6035 Drainage Revision

Total questions: 65

Worksheet time: 33mins

Name
Class
Date
1.

Which building regulation covers Drainage and Waste Disposal (Including Rainwater Guttering)?

a)

Building Regulations Part H

b)

Building Regulations Part G

c)

British Standards BS EN 12056

d)

Building Regulations Part F

2.

Fill in the blank: British Standards BS EN 12056 covers ________ Drainage Systems.

a)

Gravity

b)

Vacuum

c)

Pressure

d)

Combined

3.

Traps are installed on sanitary appliances to prevent foul air from entering the building.

a)

True

b)

False

4.

What is the purpose of ventilation at the top of soil stacks?

a)

To let noxious smells rise up into the atmosphere

b)

To allow atmospheric pressure to take place within the stack

c)

Both A and B

d)

To prevent water flow

5.

Fill in the blank: The bottom of the soil stack should have a ________ radius bend to help prevent back pressure and compression within the stack.

a)

Long

b)

Short

c)

Narrow

d)

Sharp

6.

In low rise buildings (two storeys), the lowest appliance and the invert of the drain should be ________ mm.

a)

450

b)

300

c)

600

d)

750

7.

In multi storey buildings, the distance from the lowest appliance and the invert of the drain should increase to ________ mm.

a)

750

b)

500

c)

1000

d)

1200

8.

What is the maximum distance from the invert to the ground floor for a primary stack?

a)

2.0m

b)

1.3m

c)

450mm

d)

750mm

9.

Automatic Air Vent (AAV) allows air in but no foul smells out.

a)

True

b)

False

10.

According to the diagram, if the soil stack terminates outside the property and is installed within 3 meters of an opening window, how high above the window should the stack be installed?

a)

900mm

b)

300mm

c)

1500mm

d)

600mm

11.

What is the purpose of fitting a vent terminal/cage at the top of a soil stack?

a)

To prevent blockages and wavering within traps in windy areas.

b)

To increase water pressure in the stack.

c)

To allow rainwater to enter the stack.

d)

To support the weight of the stack.

12.

Which of the following is NOT one of the three types of underground drainage systems?

a)

Separate System

b)

Combined System

c)

Partially Separate System

d)

Direct System

13.

Foul water is waste water from which of the following appliances?

a)

Toilet

b)

Basin

c)

Bath

d)

Kitchen sink

e)

All of the above

14.

Rain water is collected from which system?

a)

Soil stack

b)

Gutter system

c)

Kitchen sink

d)

Toilet

15.

Identify the soil fitting shown in the image.

a)

The image shows a type of soil pipe fitting used in drainage systems.

b)

The image shows a type of electrical conduit fitting.

c)

The image shows a type of water supply pipe fitting.

d)

The image shows a type of HVAC duct fitting.

16.

What is the waste fitting size for a washbasin?

a)

1¼”

b)

1½”

c)

NA

d)

2”

17.

Fill in the blank: The trap diameter for a bidet is _______.

a)

32mm

b)

40mm

c)

50mm

d)

25mm

18.

Which appliance has a seal depth for soil stack of 50mm?

a)

Washbasin

b)

Shower

c)

Bowl urinal

d)

Washing machine

19.

Fill in the blank: The waste fitting size for a bowl urinal is _______.

a)

1½”

b)

2”

c)

1¼”

d)

2½”

20.

What is the trap diameter for a washing machine?

a)

32mm

b)

40mm

c)

75mm

d)

100mm

21.

Fill in the blank: The seal depth for soil stack for a WC pan with 75mm trap diameter is _______.

a)

50mm

b)

75mm

c)

100mm

d)

25mm

22.

Which appliance does not have a specified waste fitting size?

a)

Dishwasher

b)

WC pan

c)

Bath

d)

Washbasin

23.

Fill in the blank: The trap diameter for a dishwasher is _______.

a)

40mm

b)

32mm

c)

50mm

d)

25mm

24.

What is the seal depth for soil stack for a bath?

a)

50mm

b)

75mm

c)

100mm

d)

NA

25.

Look at the image. What type of plumbing trap is shown?

a)

P Trap

b)

S Trap

c)

Pedestal/ Slim Line Trap

d)

Bottle Trap

26.

What type of plumbing trap is shown?

a)

P Trap

b)

S Trap

c)

Pedestal/ Slim Line Trap

d)

Bottle Trap

27.

Look at the image. What type of plumbing trap is shown?

a)

P Trap

b)

S Trap

c)

Pedestal/ Slim Line Trap

d)

Bottle Trap

28.

What type of plumbing trap is shown?

a)

Bottle Trap

b)

Anti-Vac Bottle Trap (Contains a small AAV)

c)

Self-Sealing Valve (HepvO Valve/Waterless Trap)

d)

P Trap

29.

What type of plumbing trap is shown?

a)

Bottle Trap

b)

Anti-Vac Bottle Trap (Contains a small AAV)

c)

Self-Sealing Valve (HepvO Valve/Waterless Trap)

d)

S Trap

30.

What type of plumbing trap is shown?

a)

Bottle Trap

b)

Anti-Vac Bottle Trap (Contains a small AAV)

c)

Self-Sealing Valve (HepvO Valve/Waterless Trap)

d)

Pedestal/ Slim Line Trap

31.

What is the cause of trap seal loss shown?

a)

Evaporation

b)

Loss of water due to pressure fluctuation

c)

Momentum of water carries trap seal away

d)

Positive pressure from the drain system

32.

What is the cause of trap seal loss shown?

a)

Evaporation

b)

Loss of water due to pressure fluctuation

c)

Momentum of water carries trap seal away

d)

Positive pressure from the drain system

33.

What is the cause of trap seal loss shown?

a)

Evaporation

b)

Loss of water due to pressure fluctuation

c)

Momentum of water carries trap seal away

d)

Positive pressure from the drain system

34.

What is the cause of trap seal loss shown?

a)

Evaporation

b)

Loss of water due to pressure fluctuation

c)

Momentum of water carries trap seal away

d)

Positive pressure from the drain system

35.

Which of the following is a cause of trap seal loss due to high winds and no cowl at the top of the stack?

a)

Evaporation

b)

Wavering Out

c)

Momentum

d)

Compression

36.

Which cause of trap seal loss is described as 'Large volume of water disposed of very quickly'?

a)

Evaporation

b)

Momentum

c)

Compression

d)

Induced Siphonage

37.

Compression is a cause of trap seal loss due to back pressure caused by no Long Radius Bend used at the base of the stack.

a)

True

b)

False

38.

Capillary Action in drainage systems is caused by long fibres caught in the pipe, such as hair.

a)

True

b)

False

39.

Induced Siphonage occurs when multiple appliances are connected to one waste pipe, and when one discharges it causes the other trap to empty. What size waste should be used in this scenario?

a)

32mm

b)

40mm

c)

50mm

d)

75mm

40.

Self Siphonage occurs when the waste pipe run to stack has a steep gradient causing the trap to empty itself as the appliances empty.

a)

True

b)

False

41.

During the Soundness Test, the manometer should be pumped to ___ mm and allowed to stand for ___ minutes.

a)

38 mm, 3 minutes

b)

50 mm, 5 minutes

c)

25 mm, 2 minutes

d)

45 mm, 4 minutes

42.

In the Performance Test, the trap can have no less than ___ mm of seal left after testing.

a)

25 mm

b)

10 mm

c)

40 mm

d)

60 mm

43.

What is the name of the tool shown in the image used to plug the top and bottom of the stack during the Soundness Test?

a)

Hollow Drain Plug

b)

Core Barrel

c)

Mud Balance

d)

Slurry Sampler

44.

Which drainage tool is shown in the image?

a)

Plunger

b)

Force Cup

c)

Drain Auger

d)

Drain Rods

45.

Which drainage tool is shown in the image?

a)

Plunger

b)

Force Cup

c)

Drain Auger

d)

Drain Rods

46.

Which drainage tool is shown in the image?

a)

Plunger

b)

Force Cup

c)

Drain Auger

d)

Drain Rods

47.

Which drainage tool is shown in the image?

a)

Plunger

b)

Force Cup

c)

Drain Auger

d)

Drain Rods

48.

Which gutter profile is shown in the diagram?

a)

Half Round

b)

High Capacity (Deep Flow)

c)

Square Section

d)

Ogee

49.

Which gutter profile is shown in the diagram?

a)

Half Round

b)

High Capacity (Deep Flow)

c)

Square Section

d)

Ogee

50.

Which gutter profile is shown in the diagram?

a)

Half Round

b)

High Capacity (Deep Flow)

c)

Square Section

d)

Ogee

51.

Which gutter profile is shown in the diagram?

a)

Half Round

b)

High Capacity (Deep Flow)

c)

Square Section

d)

Ogee

52.

Guttering is laid with a fall which is determined by the length (1:600), the gutter will drop 1mm for every 600mm in length. For example, a 3m gutter will have a ___ mm drop.

a)

5

b)

3

c)

6

d)

10

53.

In most uPVC gutter systems, the gap for expansion is ___ mm.

a)

10

b)

5

c)

15

d)

20

54.

Which material was used throughout the Victorian period for gutters?

a)

Cast Iron

b)

Aluminium

c)

uPVC

d)

Steel

55.

Extruded Aluminium Guttering is starting to be used now in some modern systems as it can be produced up to ___ m in length which will have no joins.

a)

30

b)

10

c)

15

d)

20

56.

Which type of connector is used to join half-round PVCu to half-round cast iron?

a)

Half-round PVCu to half-round cast iron

b)

Half-round PVCu to ogee PVCu

c)

Half-round PVCu to ogee cast iron

d)

Half-round PVCu to square-section PVCu

57.

Which type of connector is used to join half-round PVCu to ogee PVCu?

a)

Half-round PVCu to half-round cast iron

b)

Half-round PVCu to ogee PVCu

c)

Half-round PVCu to ogee cast iron

d)

Half-round PVCu to square-section PVCu

58.

Which type of connector is used to join half-round PVCu to ogee cast iron?

a)

Half-round PVCu to half-round cast iron

b)

Half-round PVCu to ogee PVCu

c)

Half-round PVCu to ogee cast iron

d)

Half-round PVCu to square-section PVCu

59.

Which type of connector is used to join half-round PVCu to square-section PVCu?

a)

Half-round PVCu to half-round cast iron

b)

Half-round PVCu to ogee PVCu

c)

Half-round PVCu to ogee cast iron

d)

Half-round PVCu to square-section PVCu

60.

Name the bracket shown in the image:

a)

Fascia Bracket

b)

Angle Bracket

c)

Cleat Bracket

d)

Shelf Bracket

61.

Name the bracket shown in the image:

a)

Rafter Bracket (Side Fitted)

b)

Angle Bracket

c)

Shelf Support Bracket

d)

Joist Hanger

62.

Name the bracket shown in the image:

a)

Rafter Bracket (Top Fitted)

b)

Angle Bracket

c)

Shelf Support Bracket

d)

Beam Clamp

63.

Name the bracket shown in the image:

a)

Drive in Bracket (Rise and Fall Bracket)

b)

Clevis Bracket

c)

Angle Bracket

d)

U Bracket

64.

What is the recommended distance between brackets when fitting them?

a)

500mm

b)

1000mm

c)

1500mm

d)

2000mm

65.

List the steps involved in fitting brackets and determining the fall.

a)

1. Establish the installation fall. 2. Fix the first brackets at the highest level on the run. 3. Fix the last bracket to give the amount of fall required. 4. Attach a string line between the two brackets. 5. Position the rest of the brackets at the recommended centres.

b)

1. Fix all brackets at equal heights. 2. Attach a string line after all brackets are fixed. 3. Establish the fall after installation. 4. Position brackets randomly.

c)

1. Establish the installation fall. 2. Fix the last bracket at the lowest level. 3. Attach a string line between all brackets. 4. Position the rest of the brackets at irregular centres.

d)

1. Fix the first bracket at the lowest level. 2. Establish the installation fall. 3. Attach a string line before fixing any brackets. 4. Position the rest of the brackets at random intervals.