wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Electrical Safety Worksheet

Total questions: 20

Worksheet time: 10mins

Name
Class
Date
1.

Basic protection against electric shock is by eliminating the possibility of coming into contact with a live part, usually by the use of insulation or barriers or enclosures.

a)

True

b)

False

c)

Don’t know

2.

A colleague suffers an electric shock when using an electric drill. Your first action ‘if safe to do so’ is:

a)

pull the drill away from them

b)

call the emergency services

c)

inform your supervisor

d)

switch the power supply off

3.

Calculate the current from a 230 V AC supply and a body resistance of 3,000 Ω.

a)

13A

b)

76mA

c)

13mA

d)

76A

4.

Which time/current zone represents the most serious hazard to the human body, including ventricular fibrillation, cardiac arrest and death.

a)

Zone 1

b)

Zone 2

c)

Zone 3

d)

Zone 4

5.

The main electrical hazards are:

a)

contact with live parts causing shock and burns

b)

faults which could cause fire

c)

fire or explosion where electricity could be the source of ignition

d)

All the above

6.

In the case of working on industrial trucks we consider high voltage as to be above:

a)

up to and including 1000vac / 1500vdc

b)

above 50Vac/120Vdc

c)

up to and including 400vac / 750vdc

d)

in excess of 1500vac / 1000vdc

7.

Identify the Non-Statutory Regulations from the following list which impact electrical installation systems:

a)

Health and Safety at Work Act 1974

b)

Electricity at Work Regulations 1989

c)

The IEE Regulations BS 7671: 2018

d)

The BSI Kite Safety Mark.

8.

What component is used to verify the test meter is functioning correctly?

a)

Megger

b)

A volt meter

c)

A Battery and bulb

d)

Proving unit or use a known power source

9.

What category (CAT) meter would be best suited in diagnosing an AC motor fault on MHE with potential high transient voltages?

a)

CAT I

b)

CAT II

c)

CAT III

d)

CAT VI

10.

Mult-meter test leads and probes should be in compliance with:

a)

HSE GS83

b)

HSE GS38

c)

HSE38

d)

GSE38

11.

It is strongly recommended probes should be:

a)

Insulated to leave an exposed metal tip not exceeding 3 mm measured across any surface of the tip.

b)

Insulated to leave an exposed metal tip not exceeding 1 mm measured across any surface of the tip.

c)

Insulated to leave an exposed metal tip not exceeding 2 mm measured across any surface of the tip.

d)

Insulated to leave an exposed metal tip not exceeding 4 mm measured across any surface of the tip.

12.

Which of the following PPE is required for high voltage electrical?

a)

face shields

b)

overalls with non-conductive fasteners

c)

safety footwear with rubber soles and non-metallic toe caps

d)

Insulated gloves

e)

All of the above

13.

What voltage should the electrical tooling being insulated too?

a)

500V

b)

1000mV

c)

1000V

d)

750V

14.

Protection against electric shock from direct contact is:

a)

Enclosure of live conductors

b)

Circuit protected by an RCD

c)

The circuit is earthed

15.

What are the requirements before commencing any work on a HV system?

a)

To be competent

b)

Have the correct PPE and insulated tooling

c)

Isolated circuit (lock out / tag out)

d)

Completed a risk assessment

e)

All of the above

16.

A short circuit is defined as:

a)

an undercurrent resulting from a fault of negligible impedance between live conductors

b)

an overcurrent resulting from a fault of negligible impedance between live conductors

c)

an overcurrent resulting from a fault of negligible impedance between live and earth conductors

17.

A current which exceeds the rated current in an otherwise healthy circuit is one definition of:

a)

fault protection

b)

an overcurrent

c)

a short-circuit current

d)

an overload current

18.

Once the power source has been isolated, how do you inform others to ensure the system will not be reenergised?

a)

Display warning notices (tagout)

b)

Lockout isolator (lockout)

c)

Lockout isolator (lockout) & Display warning notices (tagout)

19.

How long should be allowed for capacitors to discharge before commencing work

a)

5 minutes

b)

20 minutes

c)

Follow manufacturers recommendations

d)

There is no requirement to wait, its isolated

20.

Identify potential high voltage that could be stored or generated on MH equipment

a)

Capacitors

b)

Regen braking

c)

AC Motors and controllers

d)

All of the above