Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Review 2 11-25

Total questions: 21

Worksheet time: 21mins

Name
Class
Date
1.

EASY. True or False.

Conduit systems to be occupied by communication conductors shall be separated from conduit systems to be used for supply systems by not less than 75mm of concrete.

(a)  

2.

EASY. True or False. Existing installation, including maintenance replacements that currently comply with prior or old edition of the CODE, SHALL be modified to comply with the latest edition of PEC 2.

(a)  

3.

EASY. True or False.
Vegetation Clearances to power line is not Covered in the PEC 2

(a)  

4.

EASY. True or False.

The 2017 Philippine Electrical Code Part 1 has been patterned after the National Electrical Code 2017 version as it was found to be most appropriate and applicable to Philippine Setting.

(a)  

5.

EASY. The ratio of the maximum demand of the system to the total connected load of the system is called the (a)   of the system.

6.

EASY. True or False

In case where service has been cut off for more than 1 year, a new certificate of final inspection shall be required before reconnection.

(a)  

7.

EASY. Wind Electric Systems is under what chapter in PEC 1?

(a)  

8.

EASY. What is the highest basic wind speed based on PEC2 2020 Edition?

(a)  

9.

AVERAGE. What is an overcurrent protective device that generally consists of a control module that provides current. sensing, electronically derived time-current characteristics, energy to initiate tripping and an interrupting module. that interrupts current when an overcurrent occurs?

(a)  

10.

AVERAGE. Any window used or designed to be used for the display of goods or advertising material, whether it is fully or partly enclosed or entirely open at the rear and whether or not it has a platform raised higher than the street floor level.

(a)  

11.

AVERAGE. The utility for maintenance and operational purposes, Shall have the right to remove or trim/prune non-tall growing plants encroaching within (a)   meters zone from pole structure at a height deemed appropriate by the utility

12.

AVERAGE. The width of the working space in front of the electric equipment shall be the width of the equipment or (a)   , whichever is greater.

13.

AVERAGE. Appliance receptacle outlets installed in a dwelling unit for specific appliances, such as laundry equipment, shall be installed within (a)   mm of the intended location of the appliance.

14.

AVERAGE. A non-power limited fire alarm circuit cannot exceed (a)   Volts.

15.

AVERAGE. When a single piece of equipment is within sight of another piece of equipment, the pieces must be within how many feet of each other?

(a)  

16.

AVERAGE. Minimum headroom shall be provided for all working spaces about service equipment, switchboards, panelboards or motor control centers except in service equipment or panelboards in dwelling units that do not exceed (a)   amperes.

17.

DIFFICULT. Tap devices used in FC assemblies shall be rated at not less than _____ amps or more than ____ volts and they shall be color-coded in accordance with the requirements of 363-20.

(a)  

18.

DIFFICULT. Storage batteries shall be of suitable rating and capacity to supply and maintain the total load for a minimum period of ____ hrs, without the voltage applied to the load falling below ___ percent of the nominal level.

(a)  

19.

DIFFICULT. A fuse shall have a clearing time of (a)   seconds or less at the available arcing current.

20.

DIFFICULT. Every circuit breaker having an interrupting rating other than (a)   amperes shall have its interrupting rating shown on the circuit breaker.

21.