WorksheetsFinal Exam Structure Set 1
Total questions: 50
Worksheet time: 1hrs 15mins
Write the letter of the correct answer on the space provided. Philippine Agricultural Engineering Standard (PAES) for milking parlor.
PAES 407
PAES 408
PAES 409
PAES 410
Write the letter of the correct answer on the space provided. Floor space requirement for broiler 4 weeks and below per 100 birds.
6.50 m²
6.25 m²
12.5 m²
12.25 m²
Write the letter of the correct answer on the space provided. Recommended spacing between piles in a warehouse.
1 m
2 m
3 m
4 m
Write the letter of the correct answer on the space provided. Which of the following is NOT an additional requirement for “AAA” slaughterhouse?
Office for NMIC Personnel
Veterinarian
DENR Approval (E.C.C.)
Pest Control Program
Write the letter of the correct answer on the space provided. Which of the following is the recommended position of the lairage with respect to the slaughterhouse?
Slaughterhouse must be positioned downhill and downwind of the lairage.
Lairage must be positioned uphill and upwind of the slaughterhouse.
Lairage must be positioned downhill and downwind of the slaughterhouse.
Slaughterhouse must be positioned uphill and downwind of the lairage.
Write the letter of the correct answer on the space provided. Warehouse dimension if 50,000 bags are to be stored.
10 m × 30 m
16 m × 48 m
20 m × 60 m
25 m × 78 m
Write the letter of the correct answer on the space provided. What is the minimum shoulder width for one lane concrete road carriageway?
0.5 m
1 m
2.5 m
1.5 m
Write the letter of the correct answer on the space provided. Minimum height of the building sidewalls of swine housing.
1 mm
1000 mm
100 mm
10 mm
Write the letter of the correct answer on the space provided. Maximum center to center spacing of pen posts in carabao feedlot.
3.0 m
2.0 m
1.5 m
2.5 m
Write the letter of the correct answer on the space provided. Minimum floor space requirement for milking and dry cows.
4 m²
5 m²
6 m²
10 m²
Write the letter of the correct answer on the space provided. Preferred angle of intersection of the proposed roadway to the existing road.
90°
45°
60°
80°
Write the letter of the correct answer on the space provided. An area on a cattle corral used to funnel cattle into the working chute.
Holding pen
Crowding pen
Holding chute
Loading chute
Write the letter of the correct answer on the space provided. Recommended fenced loafing area per 50 heads in goat and sheep housing.
150 mm²
150 m²
150 cm²
150 in²
Write the letter of the correct answer on the space provided. Slaughterhouse with required facilities and operational procedures to serve local markets within the country.
“A”
“AAA”
“AA”
“AAAA”
Write the letter of the correct answer on the space provided. Minimum space requirement per animal in a carabao feedlot.
2 m²
4 m²
6 m²
8 m²
Write the letter of the correct answer on the space provided. Minimum pavement width for a two lane road carriageway.
2.5 m
5 m
4 m
2 m
Write the letter of the correct answer on the space provided. Minimum distance of the milking parlor from the manure piles or wastewater pond.
50 m
100 m
150 m
200 m
Write the letter of the correct answer on the space provided. Which of the following is not a recommended characteristic of litter material?
Soft and compressible
Have a medium particle size
High thermal conductivity
Dry rapidly
Write the letter of the correct answer on the space provided. The allowance for every machine/equipment in determining the storage area in a machinery shed.
0.3 m
0.4 m
0.5 m
0.6 m
Write the letter of the correct answer on the space provided. It is the rate of increase or decrease in the level of a land.
gradient
grade
gradation
grading
Write the letter of the correct answer on the space provided. Floor elevation above grounds of the warehouse to permit easy loading or unloading into trucks at the sides of the warehouse.
1 m
2 m
3 m
4 m
Write the letter of the correct answer on the space provided. Maximum center to center spacing of pen posts in cattle feedlot.
1.50 m
3.00 m
3.50 m
2.00 m
Write the letter of the correct answer on the space provided. The minimum distance of the machinery shop and shed from other buildings.
30 m
45 m
50 m
60 m
Minimum space requirement of the holding and wash pen area of a milking parlor.
2.32 m2
2.23 m2
2.32 mm2
2.23 mm2
Buildings for fabrication, repair and maintenance of tools, implements, equipments and parts of structures and provides a place where tools, supplies and spare parts are stored.
Farm workshop
Machinery shed
Warehouse
Storage
Minimum recommended space requirement for adult pigs in group.
1 m2 /animal
2.5 m2 /animal
7.5 m2 /animal
1.2 m2 /animal
Minimum distance required for slaughterhouse from building used for human habitation, factory, public roads and places.
50 m
100 m
150 m
200 m
Minimum floor space requirement of a 50 kg ewe in a slotted floor.
1.1 m2
0.9 m2
2.5 m2
0.7 m2
Minimum space requirements of layers at laying stage in a slotted floor per 100 birds.
17 m2
9 m2
14 m2
6 m2
Property of soil which describes the distribution of size groups.
Grade
Gradation
Gradient
Grading
The sows are removed when the piglets reach weaning age. The pigs remain in the same building from farrowing until they reach the desired weight for slaughtering.
1-unit system
2-unit system
3-unit system
4-unit system
Designated compartment in the lairage used to separate sick and injured animals identified at the unloading area.
Isolation pen
Stunning pen
Holding pen
Detention pen
Area with its physical facilities used for carabao fattening.
Loading area
Working area
Housing for dairy
Feedlot
Greenhouse construction where modular roof units are connected at the eave by a common gutter.
Ridge and furrow greenhouse
Quonset greenhouse
Uneven arch greenhouse
Saw tooth greenhouse
A type of goat housing where animals can move freely in or out of the housing area and into the paddock or feeding area.
Shed type
Loose housing
Stall barns
Confine housing
Minimum floor space requirement of broilers above 4 weeks old for 100 birds.
7.25 m2
12.5 m2
14.5 m2
6.25 m2
Ceiling height shall be at least how many meters high?
2.2
2.3
2.4
2.5
What is the minimum width of access alley in a cattle ranch?
2 m
3 m
4 m
5 m
Recommended floor space requirement of cows in maternity stall in dairy cattle housing.
4 m2
5 m2
6 m2
10 m2
The length of the greenhouse should not exceed by:
40 m
50 m
60 m
70 m
What is the recommended slope of concrete floors in animal housing towards the drainage?
2–4%
4–7%
3–5%
5–10%
What is the maximum distance of the milking parlor from the lactating barn if milking frequency is three times a day?
30 m
180 m
275 m
100 m
Which of the following is the recommended shape of the crowding pen in a cattle corral?
Trapezoidal
Rectangular
Circular
Any shape
What is the recommended orientation of animal housing?
east-west
west-south
south-north
east-nort
It is the process of removing the internal organs in the abdominal and thoracic cavities.
Dressing
Slaughtering
Evisceration
Shackling
Minimum floor thickness in a carabao feedlot.
74 mm
75 mm
76 mm
77 mm
What is the recommended minimum distance of the farmworkshop and machinery shed from other buildings?
40 m
45 m
50 m
55 m
What is the maximum center-to-center spacing between horizontal railing members of pen wall in a cattle feedlot?
200 mm
300 mm
400 mm
500 mm
It is the average number of farrowings of one sow per year.
Litter index
Litter
Farrowing
Occupancy rate
Piling system in large scale warehouse where sacks are piled side by side and one on top of the other for appropriate pest control measures.
Block stacking
Chinese method
Japanese method
Criss-cross stacking